22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses

被引:31
作者
Sterlacci, William [1 ]
Sioulas, Athanasios D. [2 ]
Veits, Lothar [1 ]
Goenuellue, Pervin [2 ]
Schachschal, Guido [2 ]
Groth, Stefan [2 ]
Anders, Mario [2 ]
Kontos, Christos K. [3 ]
Topalidis, Theodoros [4 ]
Hinsch, Andrea [5 ]
Vieth, Michael [1 ]
Roescch, Thomas [2 ]
Denzer, Ulrike W. [2 ]
机构
[1] Clin Bayreuth, Inst Pathol, D-95445 Bayreuth, Germany
[2] Univ Hosp Hamburg Eppendorf, Dept Interdisciplinary Endoscopy, Martinistr 52, D-20246 Hamburg, Germany
[3] Univ Athens, Dept Biochem & Mol Biol, Athens 15701, Greece
[4] Inst Pathol, D-30539 Hannover, Germany
[5] Univ Hosp Hamburg Eppendorf, Inst Pathol, D-20246 Hamburg, Germany
关键词
Endoscopic ultrasound; Cytology; Fine needle aspiration; Abdominal tumors; Core biopsy needle; SOLID PANCREATIC MASSES; BIOPSY NEEDLE; DIAGNOSTIC-ACCURACY; TISSUE ACQUISITION; HISTOLOGY NEEDLE; TRUCUT BIOPSY; EUS-FNA; YIELD; LESIONS; FEASIBILITY;
D O I
10.3748/wjg.v22.i39.8820
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM To compare the aspiration needle (AN) and core biopsy needle (PC) in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of abdominal masses. METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge (G) AN (Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22G PC (EchoTip ProCore; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications. RESULTS Fifty six consecutive patients (29 men; mean age 68 years) with pancreatic lesions (n = 38), lymphadenopathy (n = 13), submucosal tumors (n = 4), or others lesions (n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy (AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy (AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes (AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score (AN: 1.7 vs PC: 1.1, P = 0.058), and complications (none). A diagnosis on the basis of histology was achieved in the PC group in 36 (64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN (AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance. CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.
引用
收藏
页码:8820 / 8830
页数:11
相关论文
共 42 条
  • [11] Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses
    Iglesias-Garcia, Julio
    Dominguez-Munoz, Enrique
    Lozano-Leon, Antonio
    Abdulkader, Ihab
    Larino-Noia, Jose
    Antunez, Jose
    Forteza, Jeronimo
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (02) : 289 - 293
  • [12] Influence of On-Site Cytopathology Evaluation on the Diagnostic Accuracy of Endoscopic Ultrasound-Guided Fine Needle Aspiration (EUS-FNA) of Solid Pancreatic Masses
    Iglesias-Garcia, Julio
    Enrique Dominguez-Munoz, J.
    Abdulkader, Ihab
    Larino-Noia, Jose
    Eugenyeva, Elena
    Lozano-Leon, Antonio
    Forteza-Vila, Jeronimo
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 (09) : 1705 - 1710
  • [13] Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study
    Iglesias-Garcia, Julio
    Poley, Jan-Werner
    Larghi, Alberto
    Giovannini, Marc
    Chiara Petrone, Maria
    Abdulkader, Ihab
    Monges, Genevieve
    Costamagna, Guido
    Arcidiacono, Paolo
    Biermann, Katharina
    Rindi, Guido
    Bories, Erwan
    Dogloni, Claudio
    Bruno, Marco
    Enrique Dominguez-Munoz, J.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2011, 73 (06) : 1189 - 1196
  • [14] High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions
    Iwashita, Takuji
    Nakai, Yousuke
    Samarasena, Jason B.
    Park, Do Hyun
    Zhang, Zesong
    Gu, Mai
    Lee, John G.
    Chang, Kenneth J.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2013, 77 (06) : 909 - 915
  • [15] Comparison of 22-gauge aspiration needle with 22-gauge biopsy needle in endoscopic ultrasonography-guided subepithelial tumor sampling
    Kim, Gwang Ha
    Cho, Yu Kyung
    Kim, Eun Young
    Kim, Hyung Kil
    Cho, Jin Woong
    Lee, Tae Hee
    Moon, Jeong Seop
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2014, 49 (03) : 347 - 354
  • [16] Value of EUS-FNA cytological preparations compared with cell block sections in the diagnosis of pancreatic solid tumours
    Kopelman, Y.
    Marmor, S.
    Ashkenazi, I.
    Fireman, Z.
    [J]. CYTOPATHOLOGY, 2011, 22 (03) : 174 - 178
  • [17] EUS-guided trucut needle biopsies in patients with solid pancreatic masses: a prospective study
    Larghi, A
    Verna, EC
    Stavropoulos, SN
    Rotterdam, H
    Lightdale, CJ
    Stevens, PD
    [J]. GASTROINTESTINAL ENDOSCOPY, 2004, 59 (02) : 185 - 190
  • [18] Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study
    Larghi, Alberto
    Iglesias-Garcia, Julio
    Poley, Jan-Werner
    Monges, Genevieve
    Petrone, Maria Chiara
    Rindi, Guido
    Abdulkader, Ihab
    Arcidiacono, Paolo Giorgio
    Costamagna, Guido
    Biermann, Katharina
    Bories, Erwan
    Doglioni, Claudio
    Enrique Dominguez-Munoz, J.
    Hassan, Cesare
    Bruno, Marco
    Giovannini, Marc
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (10): : 3733 - 3738
  • [19] EUS-guided fine-needle tissue acquisition by using a 19-gauge needle in a selected patient population: a prospective study
    Larghi, Alberto
    Verna, Elizabeth C.
    Ricci, Riccardo
    Seerden, Tom C.
    Galasso, Domenico
    Carnuccio, Antonella
    Uchida, Naohito
    Rindi, Guido
    Costamagna, Guido
    [J]. GASTROINTESTINAL ENDOSCOPY, 2011, 74 (03) : 504 - 510
  • [20] Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis
    LeBlanc, JK
    Ciaccia, D
    Al-Assi, MT
    McGrath, K
    Imperiale, T
    Tao, LC
    Vallery, S
    DeWitt, J
    Sherman, S
    Collins, E
    [J]. GASTROINTESTINAL ENDOSCOPY, 2004, 59 (04) : 475 - 481