22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses

被引:31
作者
Sterlacci, William [1 ]
Sioulas, Athanasios D. [2 ]
Veits, Lothar [1 ]
Goenuellue, Pervin [2 ]
Schachschal, Guido [2 ]
Groth, Stefan [2 ]
Anders, Mario [2 ]
Kontos, Christos K. [3 ]
Topalidis, Theodoros [4 ]
Hinsch, Andrea [5 ]
Vieth, Michael [1 ]
Roescch, Thomas [2 ]
Denzer, Ulrike W. [2 ]
机构
[1] Clin Bayreuth, Inst Pathol, D-95445 Bayreuth, Germany
[2] Univ Hosp Hamburg Eppendorf, Dept Interdisciplinary Endoscopy, Martinistr 52, D-20246 Hamburg, Germany
[3] Univ Athens, Dept Biochem & Mol Biol, Athens 15701, Greece
[4] Inst Pathol, D-30539 Hannover, Germany
[5] Univ Hosp Hamburg Eppendorf, Inst Pathol, D-20246 Hamburg, Germany
关键词
Endoscopic ultrasound; Cytology; Fine needle aspiration; Abdominal tumors; Core biopsy needle; SOLID PANCREATIC MASSES; BIOPSY NEEDLE; DIAGNOSTIC-ACCURACY; TISSUE ACQUISITION; HISTOLOGY NEEDLE; TRUCUT BIOPSY; EUS-FNA; YIELD; LESIONS; FEASIBILITY;
D O I
10.3748/wjg.v22.i39.8820
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM To compare the aspiration needle (AN) and core biopsy needle (PC) in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of abdominal masses. METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge (G) AN (Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22G PC (EchoTip ProCore; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications. RESULTS Fifty six consecutive patients (29 men; mean age 68 years) with pancreatic lesions (n = 38), lymphadenopathy (n = 13), submucosal tumors (n = 4), or others lesions (n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy (AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy (AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes (AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score (AN: 1.7 vs PC: 1.1, P = 0.058), and complications (none). A diagnosis on the basis of histology was achieved in the PC group in 36 (64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN (AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance. CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.
引用
收藏
页码:8820 / 8830
页数:11
相关论文
共 42 条
  • [1] Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions
    Alatawi, Abdullah
    Beuvon, Frederic
    Grabar, Sophie
    Leblanc, Sarah
    Chaussade, Stanislas
    Terris, Benoit
    Barret, Maximilien
    Prat, Frederic
    [J]. UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2015, 3 (04) : 343 - 352
  • [2] A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition
    Bang, Ji Young
    Hawes, Robert
    Varadarajulu, Shyam
    [J]. ENDOSCOPY, 2016, 48 (04) : 339 - 349
  • [3] Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions
    Bang, Ji Young
    Hebert-Magee, Shantel
    Trevino, Jessica
    Ramesh, Jayapal
    Varadarajulu, Shyam
    [J]. GASTROINTESTINAL ENDOSCOPY, 2012, 76 (02) : 321 - 327
  • [4] Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope
    Binmoeller, KF
    Thul, R
    Rathod, V
    Henke, P
    Brand, B
    Jabusch, HC
    Soehendra, N
    [J]. GASTROINTESTINAL ENDOSCOPY, 1998, 47 (02) : 121 - 127
  • [5] Direct histological processing of EUS biopsies enables rapid molecular biomarker analysis for interventional pancreatic cancer trials
    Brais, Rebecca J.
    Davies, Susan E.
    O'Donovan, Maria
    Simpson, Ben W.
    Cook, Natalie
    Darbonne, Walter C.
    Chilcott, Sian
    Lolkema, Martijn P.
    Neesse, Albrecht
    Lockley, Michelle
    Corrie, Pippa G.
    Jodrell, Duncan I.
    Praseedom, Raaj K.
    Huguet, Emmanuel L.
    Jah, Asif
    Jamieson, Neville V.
    de Sauvage, Frederic J.
    Tuveson, David A.
    Carroll, Nicholas R.
    [J]. PANCREATOLOGY, 2012, 12 (01) : 8 - 15
  • [6] Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: Diagnostic accuracy and acute and 30-day complications
    Eloubeidi, MA
    Chen, VK
    Eltoum, IA
    Jhala, D
    Chhieng, DC
    Jhala, N
    Vickers, SM
    Wilcox, CM
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (12) : 2663 - 2668
  • [7] Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies
    Erickson, RA
    Sayage-Rabie, L
    Beissner, RS
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (02) : 184 - 190
  • [8] Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration
    Fabbri, Carlo
    Luigiano, Carmelo
    Maimone, Antonella
    Tarantino, Ilaria
    Baccarini, Paola
    Fornelli, Adele
    Liotta, Rosa
    Polifemo, Annamaria
    Barresi, Luca
    Traina, Mario
    Virgilio, Clara
    Cennamo, Vincenzo
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (06): : 1586 - 1590
  • [9] The evolution of endoscopic ultrasound: improved imaging, higher accuracy for fine needle aspiration and the reality of endoscopic ultrasound-guided interventions
    Hawes, Robert H.
    [J]. CURRENT OPINION IN GASTROENTEROLOGY, 2010, 26 (05) : 436 - 444
  • [10] Feasibility and efficiency of a new 22G core needle: a prospective comparison study
    Hucl, Tomas
    Wee, Eric
    Anuradha, Sekaran
    Gupta, Rajesh
    Ramchandani, Mohan
    Rakesh, Kalpala
    Shrestha, Ramila
    Reddy, Duvvuru Nageshwar
    Lakhtakia, Sundeep
    [J]. ENDOSCOPY, 2013, 45 (10) : 792 - 798