OUTCOMES OF 20-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY

被引:6
作者
Spierer, Oriel [1 ]
Siminovsky, Zvia [1 ]
Loewenstein, Anat [1 ]
Barak, Adiel [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Sourasky Med Ctr, Dept Ophthalmol, IL-64239 Tel Aviv, Israel
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2011年 / 31卷 / 09期
关键词
pars plana vitrectomy; transconjunctival sutureless vitrectomy; 20-gauge transconjunctival sutureless vitrectomy; PARS-PLANA VITRECTOMY; SELF-SEALING SCLEROTOMIES; POSTERIOR SEGMENT DISEASE; 25-GAUGE VITRECTOMY; 23-GAUGE VITRECTOMY; INITIAL-EXPERIENCE; VISUAL OUTCOMES; TERM OUTCOMES; SURGERY; ENDOPHTHALMITIS;
D O I
10.1097/IAE.0b013e31820ba09f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the effectiveness and safety of the 20-gauge transconjunctival sutureless vitrectomy system in vitreoretinal surgeries. Methods: The charts of 102 consecutive patients who underwent 20-gauge transconjunctival sutureless vitrectomy by 1 surgeon were retrospectively reviewed. The main outcome measures were intraoperative and postoperative complications and postoperative intraocular pressure and Snellen visual acuity relative to preoperative values. Patients were evaluated before surgery and 1 day, 1 week, 1 month, and 3 months postoperatively. Results: No trocar-related intraoperative complications were recorded. Two patients (2%) each required suturing of 1 sclerotomy because of leakage at completion of surgery. Mean preoperative visual acuity (in logarithm of the minimum angle of resolution units) was 1.1 +/- 0.6. By 3 months after surgery, the mean visual acuity had improved to 0.8 +/- 0.5 (P < 0.001). Mean preoperative intraocular pressure was 14.7 +/- 5.1 mmHg. Mean postoperative intraocular pressure was 14.2 +/- 5.5 mmHg (P = 0.48) at Day 1 and 14.6 +/- 4.3 mmHg (P = 0.82) at Day 7 after surgery. Hypotony was present in 3 patients (3%) on the first postoperative day, but their intraocular pressure normalized spontaneously within 1 week. None of the patients developed postoperative endophthalmitis or retinal detachment. Conclusion: Twenty-gauge transconjunctival sutureless vitrectomy is a safe and effective technique for the surgical treatment of a variety of vitreoretinal pathologies. RETINA 31: 1765-1771, 2011
引用
收藏
页码:1765 / 1771
页数:7
相关论文
共 32 条
[1]   Sutureless pars plana vitrectomy through self-sealing sclerotomies [J].
Chen, JC .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) :1273-1275
[2]   Transconjunctival sutureless 23-gauge vitrectomy [J].
Eckardt, C .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2005, 25 (02) :208-211
[3]   Outcomes of 77 consecutive cases of 23-gauge transconjunctival vitrectomy surgery for posterior segment disease [J].
Fine, Howard F. ;
Iranmanesh, Reza ;
Iturralde, Diana ;
Spaide, Richard F. .
OPHTHALMOLOGY, 2007, 114 (06) :1197-1200
[4]   Initial experience using the Transconjunctival Sutureless Vitrectomy System for vitreoretinal surgery [J].
Fujii, GY ;
de Juan, E ;
Humayun, MS ;
Chang, TS ;
Pieramici, DJ ;
Barnes, A ;
Kent, D .
OPHTHALMOLOGY, 2002, 109 (10) :1814-1820
[5]   A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery [J].
Fujii, GY ;
de Juan, E ;
Humayun, MS ;
Pieramici, DJ ;
Chang, TS ;
Ng, E ;
Barnes, A ;
Wu, SL ;
Sommerville, DN .
OPHTHALMOLOGY, 2002, 109 (10) :1807-1812
[6]   Short-term outcomes of 23-gauge pars plana vitrectomy [J].
Gupta, Omesh P. ;
Ho, Allen C. ;
Kaiser, Peter K. ;
Regillo, Carl D. ;
Chen, Sanford ;
Dyer, David S. ;
Dugel, Pravin U. ;
Gupta, Sunil ;
Pollack, John S. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (02) :193-197
[7]   Endophthalmitis after Pars Plana Vitrectomy A 20-and 25-Gauge Comparison [J].
Hu, Allen Y. H. ;
Bourges, Jean-Louis ;
Shah, Sumit P. ;
Gupta, Anurag ;
Gonzales, Christine R. ;
Oliver, Scott C. N. ;
Schwartz, Steven D. .
OPHTHALMOLOGY, 2009, 116 (07) :1360-1365
[8]   Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy [J].
Ibarra, MS ;
Hermel, M ;
Prenner, JL ;
Hassan, TS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (05) :831-836
[9]   TRANSCONJUNCTIVAL 20-GAUGE PARS PLANA VITRECTOMY USING A SINGLE ENTRY CANNULATED SUTURELESS SYSTEM [J].
Kim, Judy E. ;
Shah, Sandeep N. ;
Choi, Deana L. ;
Han, Dennis P. ;
Connor, Thomas B. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (09) :1294-1298
[10]   Prophylactic intraoperative 360° laser retinopexy for prevention of retinal detachment [J].
Koh, Hyoung J. ;
Cheng, Lingyun ;
Kosobucki, Brian ;
Freeman, William R. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (06) :744-749