Measurement uncertainty in single, double and triple isotope dilution mass spectrometry

被引:30
作者
Vogl, Jochen [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
关键词
HIGH-ACCURACY METHOD; ICP-MS; PERM PROJECT; CERTIFICATION; CD;
D O I
10.1002/rcm.5306
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Triple IDMS has been applied for the first time to the quantification of element concentrations. It has been compared with single and double IDMS obtained on the same sample set in order to evaluate the advantages and disadvantages of triple IDMS over single and double IDMS as an analytical reference procedure. The measurement results of single, double and triple IDMS are indistinguishable, considering rounding due to the individual measurement uncertainties. As expected, the relative expanded uncertainties (k = 2) achieved with double IDMS (0.08 %) are dramatically smaller than those obtained with single IDMS (1.4 %). Triple IDMS yields the smallest relative expanded uncertainties (k = 2, 0.077 %) unfortunately at the expense of a much higher workload. Nevertheless triple IDMS has the huge advantage that the isotope ratio of the spike does not need to be determined. Elements with high memory effects, highly enriched spikes or highest metrological requirements may be typical applications for triple IDMS. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 18 条
[1]  
[Anonymous], GUM WORKB
[2]  
[Anonymous], 2008, 100 JCGM
[3]   Atomic weights of the elements:: Review 2000 -: (IUPAC technical report) [J].
De Laeter, JR ;
Böhlke, JK ;
De Bièvre, P ;
Hidaka, H ;
Peiser, HS ;
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 2003, 75 (06) :683-800
[4]   Uncertainty calculations for amount of chemical substance measurements performed by means of isotope dilution mass spectrometry as part of the PERM project [J].
Dobney, A ;
Klinkenberg, H ;
Souren, F ;
Van Borm, W .
ANALYTICA CHIMICA ACTA, 2000, 420 (01) :89-94
[5]  
Ellison S.L.R., 2000, EURACHEMCITAC GUIDE, V2nd
[6]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658
[7]   Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method? [J].
Heumann, KG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :318-329
[8]   Comparative studies on the certification of reference materials by ICPMS and TIMS using isotope dilution procedures [J].
Klingbeil, P ;
Vogl, J ;
Pritzkow, W ;
Riebe, G ;
Müller, J .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1881-1888
[9]   High accuracy method for the application of isotope dilution to gas chromatography/mass spectrometric analysis of gases [J].
Milton, MJT ;
Wang, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (23) :2621-2625
[10]   High accuracy method for isotope dilution mass spectrometry with application to the measurement of carbon dioxide [J].
Milton, MJT ;
Wang, JA .