A capacitive DNA sensor for sensitive detection of Escherichia coli O157:H7 in potable water based on the z3276 genetic marker: fabrication and analytical performance

被引:0
作者
Deshmukh, Rehan [1 ]
Prusty, Arun Kumar [2 ]
Roy, Utpal [1 ]
Bhand, Sunil [2 ]
机构
[1] Birla Inst Technol & Sci, Dept Biol Sci, Goa Campus,NH17B Bypass, Pilani 403726, Goa, India
[2] Birla Inst Technol & Sci, Dept Chem, Goa Campus,NH17B Bypass, Pilani 403726, Goa, India
关键词
LABEL-FREE DETECTION; THIN-FILMS; HYBRIDIZATION; IMMUNOSENSOR; BIOSENSOR; NANOPARTICLES; POLYPYRROLE; O157-H7;
D O I
10.1039/c9an02291k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a label-free biosensor for the detection of Escherichia coli O157:H7 ATCC 43895 in potable water using a newly designed DNA sensing probe targeting the z3276 genetic marker. The surface of indium tin oxide (ITO) was functionalized with the novel sensing probe by covalent coupling using APTES as a crosslinker to fabricate the DNA sensor (dubbed ZEC [z_3276 gene of E_. c_oli O157:H7 ATCC 43895]). The electrochemical characterization of the fabricated ZEC sensor was performed using cyclic voltammetry and electrochemical impedance spectroscopy. Atomic force microscopy and scanning electron microscopy revealed significant changes in the surface topographies of the fabricated ZEC sensor chip. Equivalent circuit analyses suggested the capacitive nature of the ZEC sensor chip, which demonstrated a declining trend of the capacitance value from 1.568 mu F (Bare ITO) to 1.221 mu F (after DNA hybridization). Non-faradaic sensing measurements revealed systematically declining capacitance values upon DNA hybridization, with a 10 min response time at 10 Hz frequency and 10 mV applied potential. The ZEC sensor chip exhibited linearity in the range of 0.5 to 25 pg per 10 mL for E. coli O157:H7, with ubiquitous cross-validation of each DNA concentration using quantitative PCR prior to the analyses of real water samples. The limit of detection (LOD) at 95% confidence estimated by logistic regression was 0.1 pg DNA per 10 mL of E. coli O157:H7 (equivalent to 13.67 CFU per 10 mL) with a p-value of 0.0237. Consequently, the obtained results demonstrate the possible application of the developed ZEC sensor chip for E. coli O157:H7 detection in real water samples.
引用
收藏
页码:2267 / 2278
页数:12
相关论文
共 50 条
[1]  
[Anonymous], 2011, Chron Young Sci, DOI [10.4103/2229-5186.79345, DOI 10.4103/2229-5186.79345]
[2]   Hybridization assay at a disposable electrochemical biosensor for the attomole detection of amplified human cytomegalovirus DNA [J].
Azek, F ;
Grossiord, C ;
Joannes, M ;
Limoges, B ;
Brossier, P .
ANALYTICAL BIOCHEMISTRY, 2000, 284 (01) :107-113
[3]   A facile method of achieving low surface coverage of Au nanoparticles on an indium tin oxide electrode and its application to protein detection [J].
Aziz, Md. Abdul ;
Patra, Srikanta ;
Yang, Haesik .
CHEMICAL COMMUNICATIONS, 2008, (38) :4607-4609
[4]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[5]  
2-B
[6]   The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments [J].
Bustin, Stephen A. ;
Benes, Vladimir ;
Garson, Jeremy A. ;
Hellemans, Jan ;
Huggett, Jim ;
Kubista, Mikael ;
Mueller, Reinhold ;
Nolan, Tania ;
Pfaffl, Michael W. ;
Shipley, Gregory L. ;
Vandesompele, Jo ;
Wittwer, Carl T. .
CLINICAL CHEMISTRY, 2009, 55 (04) :611-622
[7]   Characterization of alkanethiol-self-assembled monolayers-modified gold electrodes by electrochemical impedance spectroscopy [J].
Campuzano, S ;
Pedrero, M ;
Montemayor, C ;
Fatás, E ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 586 (01) :112-121
[8]   The ecological habitat and transmission of Escherichia coli O157:H7 [J].
Chekabab, Samuel Mohammed ;
Paquin-Veillette, Judith ;
Dozois, Charles M. ;
Harel, Josee .
FEMS MICROBIOLOGY LETTERS, 2013, 341 (01) :1-12
[9]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[10]   Strategies for the detection of Escherichia coli O157:H7 in foods [J].
Deisingh, AK ;
Thompson, M .
JOURNAL OF APPLIED MICROBIOLOGY, 2004, 96 (03) :419-429