Experimental and numerical investigation into the behaviour of face-to-face built-up cold-formed steel channel sections under compression

被引:153
作者
Roy, Krishanu [1 ]
Mohammadjani, Chia [1 ]
Lim, James B. P. [1 ]
机构
[1] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
关键词
Face-to-face channels; Cold-formed steel; Buckling; Fastener spacing; Finite element modelling; Built-up columns; Axial strength; FLANGE LOADING CONDITION; WEB CRIPPLING BEHAVIOR; NONLINEAR BEHAVIOR; I-SECTION; DESIGN; HOLES; STRENGTH; COLUMNS; CAPACITY; TESTS;
D O I
10.1016/j.tws.2018.09.045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Face-to-face built-up cold-formed steel channel sections are becoming increasingly popular for column members in cold-formed steel structures; its applications include cold-formed steel trusses, space frames and portal frames. In such an arrangement, the independent buckling of the members is resisted by intermediate fasteners. In the literature, no research is available for such face-to-face built-up cold-formed steel columns. The issue is addressed herein. This paper presents the results of 36 experimental tests, conducted on face-to-face built-up cold-formed steel channel-sections covering a wide range of slenderness from stub to slender columns. A nonlinear finite element model is then described that shows good agreement with the experimental results. The finite element model includes material non-linearity, initial imperfections and modelling of intermediate fasteners. Both finite element and experimental results are compared against the design strengths calculated in accordance with the American Iron and Steel Institute (AISI), Australian and New Zealand Standards (AS/NZS) and Eurocode (EN 1993-1-3). The verified finite element model is used for the purposes of a parametric study comprising 90 models. The effect of fastener spacing on the axial strength was investigated. From the results of experiments and finite element investigations, it is shown that the design in accordance with the AISI & AS/NZS and Eurocode (EN 1993-1-3) is generally conservative by around 15%, however, AISI & AS/NZS and Eurocode (EN 1993-1-3) can be un-conservative by 8% on average for face-to-face built-up columns failed through local buckling.
引用
收藏
页码:291 / 309
页数:19
相关论文
共 34 条
[1]  
American Iron and Steel Institute (AISI), 2007, S100S107 AISI
[2]   Study on the Capacity of Cold-formes Steel Built-up Battened Colums Under Axial Compression [J].
Anbarasu, M. ;
Kumar, P. Bharath ;
Sukumar, S. .
LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2014, 11 (12) :2271-2283
[3]  
AS/NZS, 2005, AS/NZS 4600:2005
[4]  
B.S.E.N, 2001, TENS TEST MET MAT ME
[5]  
Crisan A., 2014, P ICTWS 2014 7 INT C
[6]   Nonlinear behaviour of built-up cold-formed steel section battened columns [J].
Dabaon, Mohamed ;
Ellobody, Ehab ;
Ramzy, Khaled .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 :16-28
[7]  
Dassault Systemes, 2015, ABAQUS 614 ANAL USER
[8]  
EC3, 2006, P BRUSS EUR COMM STA
[9]   Behavior of cold-formed steel plain angle columns [J].
Ellobody, E ;
Young, B .
JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (03) :457-466
[10]   Experimental study on the composite action in sheathed and bare built-up cold-formed steel columns [J].
Fratamico, David C. ;
Torabian, Shahabeddin ;
Zhao, Xi ;
Rasmussen, Kim J. R. ;
Schafer, Benjamin W. .
THIN-WALLED STRUCTURES, 2018, 127 :290-305