INFLUENCE OF MACHINE MILKING ON TEAT CONDITION OF DAIRY COWS

被引:0
作者
Stojnovic, Miomir [1 ]
Alaglc, Damir [1 ]
机构
[1] Visoko Gospodarsko Uciliste Krizevcima, Krizhevci 48260, Croatia
来源
AKTUALNI ZADACI MEHANIZACIJE POLJOPRIVREDE | 2011年 / 39卷
关键词
machine milking; dairy cows; teat; teat condition; ultrasonographic scanning; TISSUE CHANGES;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The paper deals with changes of some teat parameters of dairy cows caused by machine milking. Ultrasonographic scanner GE Medical Systems LOGIQ 100 PRO with linear array VE 5 - 5 MHz probe was used for scanning the teats. Scanning was conducted on a dairy farm at the Agricultural High School in Krizevci on 27 cows, nineteen of them of Holstein Friesian breed, 2 Simmental breed, 4 SimmentalxHolstein crossbred and 2 SimmentalxRed Holstein crossbred. The cows were housed in a free stall barn and milked in a herringbone 2x3 milking parlour with Alfa-Laval milking system with Duo vac milking units. Teat scanning was done just before morning milking and immediately after milking on the right side of the udders for front and rear teats. The following parameters were measured: teat canal length (TCL), teat end width (TEW), teat cistern width (TCW) and teat wall thickness (TWT). As fifth and sixth parameter ratio between teat canal length and teat end width (TCL/TEW), and teat cistern width and teat wall thickness (TCW/TWT) was calculated. Length of teat canal for the front right teat increased in average for 1.7 mm (15.4%) after milking, and 2.6 mm (26.3%) for the rear right teat. Teat end width of the front and rear right teat increased after milking for 0.8 mm (3.7%) and 0.7 mm (3.3%), respectively. Mean teat cistern width of the front right teat decreased after milking far 2.7 mm (24.4%) while for the rear right teat mean decrease was 2.9 mm (25.8%). Teat wall thickness of the front and rear right teat increased after milking for 0.5 mm (7.86%) and 1.1 mm (15.8%) respectively The ratio between teat canal length and teat end width changed for the right front teal from 0.525 before milking to 0.584 after milking, while for the right rear teat it changed from 0.501 to 0.603. The ratio between teat cistern width and teat wall thickness changed far the right front teat from 1.544 before milking to 1.082 after milking, and for the right rear teal from 1.54 to 0.987.
引用
收藏
页码:457 / 462
页数:6
相关论文
共 50 条
[31]   The effect of teat cup liner type on the teat condition of Holstein primiparous cows [J].
Bobic, Tina ;
Andrasic, Dario ;
Mijic, Pero ;
Gregic, Maja ;
Baban, Mirjana ;
Gantner, Vesna .
JOURNAL OF CENTRAL EUROPEAN AGRICULTURE, 2018, 19 (04) :766-771
[32]   INFLUENCE OF PULSATIONLESS MILKING ON TEAT CANAL KERATIN AND MASTITIS [J].
CAPUCO, AV ;
MEIN, GA ;
NICKERSON, SC ;
JACK, LJW ;
WOOD, DL ;
BRIGHT, SA ;
ASCHENBRENNER, RA ;
MILLER, RH ;
BITMAN, J .
JOURNAL OF DAIRY SCIENCE, 1994, 77 (01) :64-74
[33]   The teat cup detachment level affects milking performance in an automatic milking system with teat cleaning and milking in the same teat cup [J].
Ludi, Irene ;
Bruckmaier, Rupert M. .
JOURNAL OF DAIRY RESEARCH, 2022, 89 (03) :279-284
[34]   The Effect of Post Milking Teat Dip and Suckling on Teat Skin Condition, Bacterial Colonisation, and Udder Health [J].
Rasmussen M.D. ;
Larsen H.D. .
Acta Veterinaria Scandinavica, 1998, 39 (4) :443-452
[35]   Amount and variation of strip yields collected by a defined hand-milking method after machine milking of Holstein dairy cows [J].
Meyer, Daniela ;
Haeussermann, Angelika ;
Hartung, Eberhard .
ANIMAL, 2022, 16 (05)
[36]   Machine Milking Impact on Dairy Cows' Physiological Adjustments: an Observational Approach According to Different Breed [J].
Fazio, Esterina ;
Medica, Pietro ;
Cravana, Cristina ;
Ferlazzo, Adriana .
ACTA SCIENTIAE VETERINARIAE, 2015, 43
[37]   Milk flow-dependent vacuum loss in high-line milking systems: Effects on milking characteristics and teat tissue condition [J].
Ambord, S. ;
Bruckmaier, R. M. .
JOURNAL OF DAIRY SCIENCE, 2010, 93 (08) :3588-3594
[38]   Ultrasound teat wall diameter and cutimeter teat tissue thickness before, during, and after machine milking [J].
Bruckmaier, R. ;
Lofstrand, J. .
JOURNAL OF ANIMAL SCIENCE, 2018, 96 :263-263
[39]   Udder and teat morphometry in relation to clinical mastitis in dairy cows [J].
Sinha, Rebeka ;
Sinha, Beena ;
Kumari, Ragini ;
Vineeth, M. R. ;
Shrivastava, Kush ;
Verma, Archana ;
Gupta, I. D. .
TROPICAL ANIMAL HEALTH AND PRODUCTION, 2022, 54 (02)
[40]   REGENERATION OF TEAT CANAL KERATIN IN LACTATING DAIRY-COWS [J].
CAPUCO, AV ;
WOOD, DL ;
BRIGHT, SA ;
MILLER, RH ;
BITMAN, J .
JOURNAL OF DAIRY SCIENCE, 1990, 73 (07) :1745-1750