Markers Detection in Transformer Oil by Plasmonic Chemical Sensor System Based on POF and MIPs

被引:55
作者
Cennamo, N. [1 ]
De Maria, L. [2 ]
Chemelli, C. [2 ]
Profumo, A. [3 ]
Zeni, L. [1 ]
Pesavento, M. [3 ]
机构
[1] Univ Naples 2, Dept Ind & Informat Engn, I-81031 Aversa, Italy
[2] Res Energet Syst SpA, I-20134 Milan, Italy
[3] Univ Pavia, Dept Chem, I-27100 Pavia, Italy
关键词
Dibenzyl disulfide; furfural (furan-2-carbaldehyde); molecularly imprinted polymers; plastic optical fibers; power transformers; PLASTIC OPTICAL-FIBER; FURFURAL ANALYSIS; DIBENZYL DISULFIDE; POWER TRANSFORMERS; INSULATING OIL; RESONANCE; BIOSENSORS; CELLULOSE; SPR; DEGRADATION;
D O I
10.1109/JSEN.2016.2603168
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a multichannel optical chemical sensor based on molecularly imprinted polymers (MIPs) and surface plasmon resonance (SPR) in a D-shaped plastic optical fiber (POF), for simultaneous determination of two important analytes, dibenzyl disulfide, and furfural, whose presence in the transformer oil is an indication of underway corrosive or ageing processes, respectively, in power transformers. Furthermore, an investigation on the dependence of performances of this optical platform on the gold film thickness is reported. The low cost, highly selective, and sensitive performance of the SPR-POF-MIP platforms and the simple and modular scheme of the optical interrogation layout make this system a potentially suitable on-line diagnostic tool for power transformers.
引用
收藏
页码:7663 / 7670
页数:8
相关论文
共 43 条
  • [1] A Novel Bias Detection Technique for Partial Discharge Localization in Oil Insulation System
    Al-Masri, Wasim M. F.
    Abdel-Hafez, Mamoun F.
    El-Hag, Ayman H.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (02) : 448 - 457
  • [2] [Anonymous], 2004, IEC 60450
  • [3] [Anonymous], 2015, 62874 IEC
  • [4] Bertrand Y., 2012, D1103 CIGRE
  • [5] An enhanced fiber-optic temperature sensor system for power transformer monitoring
    Betta, G
    Pietrosanto, A
    Scaglione, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) : 1138 - 1143
  • [6] A novel optical sensor for the measurement of furfuraldehyde in transformer oil
    Blue, R
    Uttamchandani, DG
    Farish, O
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (04) : 964 - 966
  • [7] Stability and Reactivity of Sulfur Compounds against Copper in Insulating Mineral Oil: Definition of a Corrosiveness Ranking
    Bruzzoniti, Maria Concetta
    De Carlo, Rosa Maria
    Sarzanini, Corrado
    Maina, Riccardo
    Tumiatti, Vander
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (21) : 8675 - 8684
  • [8] Instrumentation System for Location of Partial Discharges Using Acoustic Detection With Piezoelectric Transducers and Optical Fiber Sensors
    Bua-Nunez, Iago
    Posada-Roman, Julio E.
    Rubio-Serrano, Jesus
    Garcia-Souto, Jose A.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (05) : 1002 - 1013
  • [9] Oil-Filled MV/LV Power-Transformer Behavior in Narrow-Band Power-Line Communication Systems
    Cataliotti, Antonio
    Cosentino, Valentina
    Di Cara, Dario
    Tine, Giovanni
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (10) : 2642 - 2652
  • [10] High selectivity and sensitivity sensor based on MIP and SPR in tapered plastic optical fibers for the detection of L-nicotine
    Cennamo, N.
    D'Agostino, G.
    Pesavento, M.
    Zeni, L.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 529 - 536