Experimental study on different preheating methods for the cold-start of PEMFC stacks

被引:86
|
作者
Zhan, Zhigang [1 ]
Yuan, Chong [1 ]
Hu, Zhangrong [1 ]
Wang, Hui [1 ]
Sui, P. C. [2 ,3 ]
Djilali, Ned [3 ]
Pan, Mu [1 ]
机构
[1] Wuhan Univ Technol, State Key Lab Adv Technol Mat Synth & Proc, Wuhan 430070, Hubei, Peoples R China
[2] Wuhan Univ Technol, Sch Automot Engn, Wuhan 430070, Hubei, Peoples R China
[3] Univ Victoria, Inst Integrated Energy Syst, Victoria, BC V8W 3P6, Canada
基金
中国国家自然科学基金;
关键词
PEMFC; Cold start; Phase-in preheating; Optimization; MEMBRANE FUEL-CELL; DEGRADATION; WATER; TEMPERATURE; TECHNOLOGY; BEHAVIORS; LAYERS; PEFCS;
D O I
10.1016/j.energy.2018.08.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Rapid and safe start-up from sub-zero temperatures for polymer electrolyte membrane fuel cells (PEMFCs) is a crucial know-how to guarantee these fuel cells' operation under severe weather conditions and to prolong their lifetime. Taking into consideration the disparity in thermal properties, different rising time in temperature and responses to preheating method and control strategy between the membrane electrode assembly and stack hardware, a phase-in preheating method is proposed in the present study. A series of cold start-up experiments for a 2 kW stack were carried out with different preheating methods, including air preheating, coolant preheating, air and end plate preheating under -10 degrees C and -20 degrees C temperature conditions. The experimental results verified the phase-in preheating strategy, and conclude that the corresponding optimal preheating method is to first preheat the stack by air and the end plates simultaneously, and to switch on the stack operation at suitable timing when the stack's temperature is above -5 degrees C. It is also found that when the stack temperature reaches a threshold value, 24 degrees C in the present study, humidification of the reactants and circulation of coolant can be started to bring the stack to normal operating conditions. A thermal analysis for energy balance in the system was performed to gain insight to the problem. By comparing the heat transfer by different fluid (air and coolant) and parts (end plates), it is found that preheating by air along is slow, whereas heating the end plates is fast and time-efficient. Furthermore, it becomes clear that the optimal preheating method is to utilize the waste heat efficiently, which can be achieved by switching on the stack operation at proper timing. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1029 / 1040
页数:12
相关论文
共 50 条
  • [1] PEMFC cold-start performance after twice purge
    Luo, Maji
    Wang, Fangfang
    Liu, Wei
    Zhan, Zhigang
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2011, 39 (06): : 116 - 120
  • [2] An experimental and numerical investigation into the influence of intake port preheating on cold-start THC emissions of a scooter engine
    Vo, Dai-Qui
    Lee, Cho -Yu
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 41
  • [3] STUDY OF WATER FREEZING AND THAWING PROCESS INSIDE THE PEMFC STACKS DURING COLD START
    Zhou, Su
    Zheng, Lan
    Chen, Fengxiang
    Zhai, Shuang
    AUTOMATION EQUIPMENT AND SYSTEMS, PTS 1-4, 2012, 468-471 : 2331 - 2334
  • [4] Study of SCR cold-start by energy method
    Miao, Yong
    Chen, Lea-Der
    He, Yongsheng
    Kuo, Tang-wei
    CHEMICAL ENGINEERING JOURNAL, 2009, 155 (1-2) : 260 - 265
  • [5] Experimental study on cold start performance of PEMFC based on parallel flow channels
    Yue, Like
    Wang, Shixue
    Zhu, Yu
    Fan, Yue
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (01) : 540 - 550
  • [6] Experimental study on rapid cold start-up performance of PEMFC system
    Wang, Feijie
    Zhang, Hailong
    Ming, Pingwin
    Yang, Daijun
    Li, Bing
    Zhang, Cunman
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (57) : 21898 - 21907
  • [7] Environment-adaptive method to control intake preheating for diesel engines at cold-start conditions
    Li, Yikai
    Wang, Dongfang
    Shi, Zhongjie
    Chen, Haiyan
    Liu, Fushui
    ENERGY, 2021, 227
  • [8] Numerical study on cold start of PEMFC with coolant circulation
    Wei L.
    Liao Z.
    Jiang F.
    Huagong Xuebao/CIESC Journal, 2019, 70 : 146 - 154
  • [9] Real-Time Control of Gas Supply System for a PEMFC Cold-Start Based on the MADDPG Algorithm
    Pan, Lei
    Zhang, Tong
    Gao, Yuan
    ENERGIES, 2023, 16 (12)
  • [10] Study to investigate the capability of adsorbents for reduction of cold-start emissions
    Miller, A.L.
    Ginter, D.
    Seaba, J.P.
    Loyalka, S.K.
    Ghosh, T.K.
    Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering, 1998, 212 (06): : 525 - 532