DCT-based objective quality assessment metric of 2D/3D image

被引:8
|
作者
Liu, Xingang [1 ]
Sun, Chao [1 ]
Yang, Laurence T. [2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Elect Engn, High Tech Zone, Xiyuan Rd 2006, Chengdu 611731, Sichuan, Peoples R China
[2] St Francis Xavier Univ, Antigonish, NS B2G 2W5, Canada
基金
中国博士后科学基金;
关键词
Quality assessment; DCT coding; Stereoscopic image; Human Visual System (HVS); Region of Interest (ROI); VIDEO;
D O I
10.1007/s11042-013-1698-z
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the increasing growth of multimedia applications over the networking in recent years, users have put forward much higher requirements for multimedia quality of experience (QoE) than before. One of the representative requirements is the image quality. Therefore, the image quality assessment ranging from two-dimension (2D) image to three-dimension (3D) image has been getting much attention. In this paper, an efficient objective image quality assessment metric in block-based discrete cosine transform (DCT) coding is proposed. The metric incorporates properties of human visual system (HVS) to improve its validity and reliability in evaluating the quality of stereoscopic image. This is fulfilled by calculating the local pixel-based distortions in frequency domain, combining the simplified models of local visibility properties embodied in frequency domain, which consist of region of interest (ROI) mechanism (visual sensitivity), contrast sensitivity function (CSF) and contrast masking effect. The performance of the proposed metric is compared with other currently state-of-the-art objective image quality assessment metrics. The experimental results have demonstrated that the proposed metric is highly consistent with the subjective test scores. Moreover, the performance of the metric is also confirmed with the popular IRCCyN/IVC database. Therefore, the proposed metric is promising in term of the practical efficiency and reliability for real-life multimedia applications.
引用
收藏
页码:2803 / 2820
页数:18
相关论文
共 50 条
  • [1] DCT-based objective quality assessment metric of 2D/3D image
    Xingang Liu
    Chao Sun
    Laurence T. Yang
    Multimedia Tools and Applications, 2015, 74 : 2803 - 2820
  • [2] 2D and 3D Image Quality Assessment: A Survey of Metrics and Challenges
    Niu, Yuzhen
    Zhong, Yini
    Guo, Wenzhong
    Shi, Yiqing
    Chen, Peikun
    IEEE ACCESS, 2019, 7 : 782 - 801
  • [3] Objective image quality metrics for DCT-based video compression
    Oguz, H
    Faibish, A
    Faibish, S
    Cotter, G
    SMPTE JOURNAL, 2002, 111 (09): : 385 - 392
  • [4] DCT-QM: A DCT-Based Quality Degradation Metric for Image Quality Optimization Problems
    Bae, Sung-Ho
    Kim, Munchurl
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2016, 25 (10) : 4916 - 4930
  • [5] Objective image quality assessment of 3D synthesized views
    Battisti, Federica
    Bosc, Emilie
    Carli, Marco
    Le Callet, Patrick
    Perugia, Simone
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 2015, 30 : 78 - 88
  • [6] A wavelet-based image quality metric for the assessment of 3D synthesized views
    Bose, Emilie
    Battisti, Federica
    Carli, Marco
    Le Callet, Patrick
    STEREOSCOPIC DISPLAYS AND APPLICATIONS XXIV, 2013, 8648
  • [7] No-reference quality assessment for DCT-based compressed image
    Wang, Ci
    Shen, Minmin
    Yao, Chen
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2015, 28 : 53 - 59
  • [8] VOLUME RENDERING OF DCT-BASED COMPRESSED 3D SCALAR DATA
    YEO, BL
    LIU, BD
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 1995, 1 (01) : 29 - 43
  • [9] Subjective and Objective Quality Assessment of 2D and 3D Foveated Video Compression in Virtual Reality
    Jin, Yize
    Chen, Meixu
    Goodall, Todd
    Patney, Anjul
    Bovik, Alan C.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2021, 30 (30) : 5905 - 5919
  • [10] A DCT-based multiscale framework for 2D greyscale image fusion using morphological differential features
    Roy, Manali
    Mukhopadhyay, Susanta
    VISUAL COMPUTER, 2024, 40 (05): : 3569 - 3590