An Investigation on the Current Collection Quality of Railway Pantograph-Catenary Systems With Contact Wire Wear Degradations

被引:20
|
作者
Song, Yang [1 ]
Wang, Hongrui [2 ]
Liu, Zhigang [3 ]
机构
[1] Delft Univ Technol, Dept Engn Struct, N-7491 Trondheim, Norway
[2] Delft Univ Technol, Dept Engn Struct, NL-2628 CN Delft, Netherlands
[3] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 610031, Peoples R China
基金
中国国家自然科学基金;
关键词
Contact force; contact wire wear (CWW); current collection quality; electrified railway; pantograph-catenary interaction; stochastic analysis; LINES;
D O I
10.1109/TIM.2021.3078530
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In railway pantograph-catenary systems, the contact surfaces undergo wear in long-term operations, directly affecting interaction performance and potentially deteriorating the current collection quality. The effect of contact wire wear (CWW) on the current collection quality should be evaluated to understand the system's health status in operations. This article presents a stochastic analysis of the pantograph-catenary interaction performance with different levels of CWW based on four years of measurement data. The power spectral density (PSD) estimation is carried out on the measured CWW to obtain their frequency representations. The random time histories of CWW are generated based on the PSDs. A nonlinear finite element model of catenary with a lumped-mass pantograph is built. Using the Monte Carlo method, the stochastic analysis of pantograph-catenary contact force is carried out to investigate the distribution and dispersion of assessment indices with different levels of CWW. The results indicate that the CWW mainly affects the maximum and minimum contact forces instead of the contact force standard deviation. The optimal pantograph-catenary interaction performance is observed certain years after CWW is formed, depending on the traffic density of the railway line, which is at the second year in the presented case study. Then, the performance declines with an increase in service time. Also, higher operating speed causes a more significant dispersion in assessment indices representing a lower current collection quality, particularly at the maximum operating speed (70% of the catenary wave propagation speed).
引用
收藏
页数:11
相关论文
共 20 条
  • [1] Contact Wire Irregularity Stochastics and Effect on High-Speed Railway Pantograph-Catenary Interactions
    Song, Yang
    Liu, Zhigang
    Ronnquist, Anders
    Navik, Petter
    Liu, Zhendong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) : 8196 - 8206
  • [2] Assessment of the Current Collection Quality of Pantograph-Catenary With Contact Line Height Variability in Electric Railways
    Song, Yang
    Duan, Fuchuan
    Wu, Fanping
    Liu, Zhigang
    Gao, Shibin
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2022, 8 (01) : 788 - 798
  • [3] Impact of Surface Roughness on Pantograph-Catenary Current Collection Quality
    Guo, Fengyi
    Wang, Xiaokang
    Kou, Jiabao
    Li, Fuhua
    Han, Congxin
    IEEE ACCESS, 2022, 10 : 93951 - 93959
  • [4] Influence of Dropper Spacing on Quality of Pantograph-Catenary Current Collection
    Yu, Meili
    Liu, Wenzheng
    Zhang, Jian
    Yan, Caiying
    MECHANICAL AND ELECTRONICS ENGINEERING VI, 2014, 654 : 78 - 81
  • [5] Identification of short-wavelength contact wire irregularities in electrified railway pantograph-catenary system
    Song, Yang
    Ronnquist, Anders
    Jiang, Tengjiao
    Navik, Petter
    MECHANISM AND MACHINE THEORY, 2021, 162
  • [6] A procedure for the wear prediction of collector strip and contact wire in pantograph-catenary system
    Bucca, Giuseppe
    Collina, Andrea
    WEAR, 2009, 266 (1-2) : 46 - 59
  • [7] The Effects of Spatially Distributed Damping on the Contact Force in Railway Pantograph-Catenary Interactions
    Song, Yang
    Jiang, Tengjiao
    Ronnquist, Anders
    Navik, Petter
    Froseth, Gunnstein
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [8] Arc distribution in pantograph-catenary contact based on double-pantograph current collection dynamics
    Zhou H.-Y.
    Liu Z.-G.
    Xiong J.-M.
    Xu Z.
    Deng Y.-C.
    Jiaotong Yunshu Gongcheng Xuebao/Journal of Traffic and Transportation Engineering, 2023, 23 (03): : 77 - 87
  • [9] Analysis of electrical interferences related to the current collection quality in pantograph-catenary interaction
    Bucca, G.
    Collina, A.
    Manigrasso, R.
    Mapelli, F.
    Tarsitano, D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2011, 225 (F5) : 483 - 499
  • [10] Crosswind Effects on Current Collection Quality of Railway Pantograph-Catenary: A Case Study in Chengdu-Chongqing Passenger Special Line
    Song, Yang
    Duan, Fuchuan
    Gao, Shibin
    Wu, Fanping
    Liu, Zhigang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71