The validity of a novel radiological method for measuring femoral stem version on anteroposterior radiographs of the hip after total hip arthroplasty

被引:0
作者
Weber, M. [1 ]
Lechler, P. [1 ]
von Kunow, R. [1 ]
Voellner, F. [1 ]
Keshmiri, A. [1 ]
Hapfelmeier, A. [1 ]
Grifka, J. [1 ]
Renkawitz, T. [1 ]
机构
[1] Univ Regensburg, Med Ctr, D-93077 Bad Abbach, Germany
关键词
ANTEVERSION; REPLACEMENT; IMPINGEMENT; OSTEOARTHRITIS; DESIGN; MOTION; OFFSET; RANGE;
D O I
10.1302/0301-620X.97133.34618
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Femoral stem version has a major influence on impingement and early post-operative stability after total hip arthroplasty (THA). The main objective of this study was to evaluate the validity of a novel radiological method for measuring stem version. Anteroposterior (AP) radiographs and three-dimensional CT scans were obtained for 115 patients (female/male 63/72, mean age 62.5 years (50 to 75)) who had undergone minimally invasive, cementless THA. Stem version was calculated from the AP hip radiograph by rotation-based change in the projected prosthetic neck-shaft (NSA*) angle using the mathematical formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent observers who repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. We found a mean difference of 1.2 degrees (SD 6.2) between radiological and 3D-CT measurements of stem version. The correlation between the mean radiological and 3D-CT stem torsion was r = 0.88 (p < 0.001). The intra- (intraclass correlation coefficient >=. 0.94) and inter-observer agreement (mean concordance correlation coefficient = 0.87) for the radiological measurements were excellent. We found that femoral tilt was associated with the mean radiological measurement error (r = 0.22, p = 0.02). The projected neck-shaft angle is a reliable method for measuring stem version on AP radiographs of the hip after a THA. However, a highly standardised radiological technique is required for its precise measurement.
引用
收藏
页码:306 / 311
页数:6
相关论文
共 28 条
[1]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[2]   MEASUREMENT OF FEMORAL NECK ANTEVERSION BY A DIRECT METHOD [J].
BUDIN, E ;
CHANDLER, E .
RADIOLOGY, 1957, 69 (02) :209-213
[3]   Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? [J].
Craiovan, Benjamin ;
Renkawitz, Tobias ;
Weber, Markus ;
Grifka, Joachim ;
Nolte, Lutz ;
Zheng, Guoyan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) :2009-2015
[4]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[5]   A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Wan, Zhinian ;
Malik, Aamer ;
Zhu, Jinjun ;
Dastane, Manish ;
Deshmane, Prashant .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) :2598-2604
[6]   EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING [J].
GOERGEN, TG ;
RESNICK, D .
BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) :259-260
[7]  
Grosflam J M, 1995, Arthritis Care Res, V8, P167, DOI 10.1002/art.1790080309
[8]   The importance of adequate stem anteversion for rotational stability in cemented total hip replacement A RADIOSTEREOMETRIC STUDY WITH TEN-YEAR FOLLOW-UP [J].
Kiernan, S. ;
Hermann, K. L. ;
Wagner, P. ;
Ryd, L. ;
Flivik, G. .
BONE & JOINT JOURNAL, 2013, 95B (01) :23-30
[9]   Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram [J].
Kjellberg, Martin ;
Al-Amiry, Bariq ;
Englund, Erling ;
Sjoden, Goran O. ;
Sayed-Noor, Arkan S. .
SKELETAL RADIOLOGY, 2012, 41 (02) :187-191
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174