Experimental investigations on the influence of 'chimney-effect' on fire response of rainscreen facades in high-rise buildings

被引:28
作者
Sharma, Ankit [1 ]
Mishra, Kirti Bhushan [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Technol Risk Res & Anal Grp TRAG, Roorkee 247667, Uttarakhand, India
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 44卷
关键词
Facades; Polymers; Fire dynamics; Insulation; Aluminium composite; High-rise buildings; Fire safety; HEAT-FLUX PROFILE; WINDOW; PERFORMANCE; BEHAVIOR; PLUME;
D O I
10.1016/j.jobe.2021.103257
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, external wall fires (or facade fires) are occurring due to mixed contribution of exterior cladding and continuous insulation in the chimney like construction of rainscreen facades. In the present work, a new experimental setup is developed and demonstrated for the initial screening of facade assembly at a lab-scale. It incorporates the real physics for investigating the fire hazards of flammable polymeric materials and the chimney effect together. Different combinations of exterior cladding (Al-45, Al-45 Class 0, Al-45 Class B) and continuous insulation (Expanded polystyrene, Polyisocyanurate and Mineral wool) with and without chimney are selected for studying their fire behaviour. The pressure differential combining with re-radiation inside the cavity led 3-6 times higher mass burning rate, flame height and temperature in tests with chimney effect to that of without for the same combination of products. With chimney, secondary fire sources are generated due to the dripping of products which further enhanced the burning and spread rate. A critical width of the chimney (13-50 mm) is established at which maximum vertical fire spread was noticed. Furthermore, the visual observations indicated that the products having thin outer Al sheets are prone to 30% early structural failure. Comparison of results with large-scale tests validated the usefulness of the current setup as an intermediate test between small and large scale for studying fire behaviour of facade materials.
引用
收藏
页数:18
相关论文
共 52 条
[1]   Fire performance evaluation of cladding wall assemblies using the 16-ft high parallel panel test method of ANSI/FM 4880 [J].
Agarwal, Gaurav ;
Wang, Yi ;
Dorofeev, Sergey .
FIRE AND MATERIALS, 2021, 45 (05) :609-623
[2]   EVALUATION OF UNSPRINKLERED FIRE HAZARDS [J].
ALPERT, RL ;
WARD, EJ .
FIRE SAFETY JOURNAL, 1984, 7 (02) :127-143
[3]  
[Anonymous], 2009, 47661989A12009 BS
[4]  
[Anonymous], 2007, 1350112007A12009 BS
[5]  
[Anonymous], 1997, 47671997 BS
[6]   Performance of a ventilated-façade system under fire conditions: An experimental investigation [J].
Asimakopoulou E.K. ;
Kolaitis D.I. ;
Founti M.A. .
Asimakopoulou, Eleni K. (easimakopoulou@uclan.ac.uk); Asimakopoulou, Eleni K. (easimakopoulou@uclan.ac.uk), 1600, John Wiley and Sons Ltd (44) :776-792
[7]   Numerical investigation of externally venting flame characteristics in a corridor-facade configuration [J].
Asimakopoulou, Eleni K. ;
Chotzoglou, Konstantinos E. ;
Kolaitis, Dionysios ;
Zhang, Jianping ;
Delichatsios, Michael A. .
FIRE SAFETY JOURNAL, 2019, 110
[8]   Thermal characteristics of externally venting flames and their effect on the exposed facade surface [J].
Asimakopoulou, Eleni K. ;
Kolaitis, Dionysios I. ;
Founti, Maria A. .
FIRE SAFETY JOURNAL, 2017, 91 :451-460
[9]  
Babrauskas V, 2018, GRENFELL TOWER FIRE
[10]  
Bonner M., 2018, International Journal of High-Rise Buildings, V7, P363, DOI DOI 10.21022/IJHRB.2018.7.4.363