Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [41] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Matthieu Bailly
    Frédérique Thibault
    Maxime Courtehoux
    Gilles Metrard
    Maria Joao Ribeiro
    Journal of Nuclear Cardiology, 2021, 28 : 2560 - 2568
  • [42] Clinical validation of SPECT attenuation correction using X-ray computed tomography-derived attenuation maps: Multicenter clinical trial with angiographic correlation
    Masood, Y
    Liu, YH
    DePuey, G
    Taillefer, R
    Araujo, LI
    Allen, S
    Delbeke, D
    Anstett, F
    Peretz, A
    Zito, MJ
    Tsatkin, V
    Wackers, FJT
    JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) : 676 - 686
  • [43] Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1090 - 1095
  • [44] Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging
    Kawakubo, Masateru
    Nagao, Michinobu
    Kaimoto, Yoko
    Nakao, Risako
    Yamamoto, Atsushi
    Kawasaki, Hiroshi
    Iwaguchi, Takafumi
    Matsuo, Yuka
    Kaneko, Koichiro
    Sakai, Akiko
    Sakai, Shuji
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (03) : 199 - 209
  • [45] Attenuation correction for myocardial perfusion imaging - A comparison between SPECT and PET imaging by polar map analysis
    Graf, S.
    Khorsand, A.
    Stix, G.
    Nekolla, S.
    Becherer, A.
    Kletter, K.
    Dudczak, R.
    Sochor, H.
    Maurer, G.
    Parenta, G.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2006, 45 (04): : 171 - 176
  • [46] An overview of attenuation and scatter correction of planar and SPECT data for dosimetry studies
    King, M
    Farncombe, T
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2003, 18 (02) : 181 - 190
  • [47] Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging
    Masateru Kawakubo
    Michinobu Nagao
    Yoko Kaimoto
    Risako Nakao
    Atsushi Yamamoto
    Hiroshi Kawasaki
    Takafumi Iwaguchi
    Yuka Matsuo
    Koichiro Kaneko
    Akiko Sakai
    Shuji Sakai
    Annals of Nuclear Medicine, 2024, 38 : 199 - 209
  • [48] The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
    Saleki, Leila
    Ghafarian, Pardis
    Bitarafan-Rajabi, Ahmad
    Yaghoobi, Nahid
    Fallahi, Babak
    Ay, Mohammad Reza
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 63 - 72
  • [49] Attenuation correction of myocardial SPECT by scatter-photopeak window method in normal subjects
    Okuda, Koichi
    Nakajima, Kenichi
    Motomura, Nobutoku
    Kubota, Masahiro
    Yamaki, Noriyasu
    Maeda, Hisato
    Matsuo, Shinro
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (05) : 501 - 506
  • [50] Quantitative Assessment of Induced Errors In Attenuation Corrected Myocardial SPECT Images Due to Misregistration
    Babaeifar, Hamidreza
    Rajabi, Hossein
    Sen, Anando
    Kalantari, Faraz
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,