Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [31] Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Liu, Bin
    Ou, Xiaohong
    Tian, Rong
    Li, Lin
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) : 344 - 349
  • [32] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Koichi Okuda
    Kenichi Nakajima
    Masato Yamada
    Hiroshi Wakabayashi
    Hajime Ichikawa
    Hiroyuki Arai
    Shinro Matsuo
    Junichi Taki
    Mitsumasa Hashimoto
    Seigo Kinuya
    Annals of Nuclear Medicine, 2014, 28 : 60 - 68
  • [33] Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
    Okuda, Koichi
    Nakajima, Kenichi
    Yamada, Masato
    Wakabayashi, Hiroshi
    Ichikawa, Hajime
    Arai, Hiroyuki
    Matsuo, Shinro
    Taki, Junichi
    Hashimoto, Mitsumasa
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 60 - 68
  • [34] Clinical validation of SPECT attenuation correction using x-ray computed tomography—derived attenuation maps: Multicenter clinical trial with angiographic correlation
    Yasmin Masood
    Yi -Hwa Liu
    Gordon DePuey
    Raymond Taillefer
    Luis I. Araujo
    Steven Allen
    Dominique Delbeke
    Frank Anstett
    Aharon Peretz
    Mary -Jo Zito
    Vera Tsatkin
    Frans J. Th. Wackers
    Journal of Nuclear Cardiology, 2005, 12 : 676 - 686
  • [35] Clinical utility of attenuation correction with X-rays in myocardial perfusion SPECT studies
    Bajen, M. T.
    Ricart, Y.
    Rodriguez-Gasen, A.
    Mora, J.
    Quintana, M. E.
    Benitez, A.
    Domenech, A.
    Ruiz-Mayoral, A.
    Puchala, R.
    Pallares, C.
    Martin-Comin, J.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2007, 26 (06): : 359 - 366
  • [36] Deep learning-guided attenuation correction in the image domain for myocardial perfusion SPECT imaging
    Mostafapour, Samaneh
    Gholamiankhah, Faeze
    Maroufpour, Sirwan
    Momennezhad, Mehdi
    Asadinezhad, Mohsen
    Zakavi, Seyed Rasoul
    Arabi, Hossein
    Zaidi, Habib
    JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2022, 9 (02) : 434 - 447
  • [37] Optimising the number of thermoluminescent dosimeters required for the measurement of effective dose for computed tomography attenuation correction data in SPECT/CT myocardial perfusion imaging
    Tootell, Andrew K.
    Szczepura, Katy R.
    Hogg, Peter
    RADIOGRAPHY, 2013, 19 (01) : 42 - 47
  • [38] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Bailly, Matthieu
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Ribeiro, Maria Joao
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2560 - 2568
  • [39] Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction
    Charline Zadro
    Noé Roussel
    Emmanuelle Cassol
    Pierre Pascal
    Antoine Petermann
    Olivier Meyrignac
    Marion Jaffro
    Pauline Fournier
    Maxime Cournot
    Michel Galinier
    Didier Carrié
    Hervé Rousseau
    Isabelle Berry
    Olivier Lairez
    Journal of Nuclear Cardiology, 2018, 25 : 1574 - 1583
  • [40] Attenuation correction in hybrid PET using X-ray computed tomography
    Uegaki, M
    Fujino, K
    Murase, K
    Kamiya, T
    Nakamura, Y
    Uenishi, Y
    Nagayoshi, M
    Kawamata, M
    Yamazaki, Y
    Oku, N
    Hatazawa, J
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1255 - 1255