Attenuation correction of myocardial SPECT studies using low resolution computed tomography images

被引:36
|
作者
Tonge, CM [1 ]
Manoharan, M [1 ]
Lawson, RS [1 ]
Shields, RA [1 ]
Prescott, MC [1 ]
机构
[1] Manchester Royal Infirm, Dept Nucl Med, Manchester M13 9WL, Lancs, England
关键词
myocardial perfusion imaging; attenuation correction; SPECT;
D O I
10.1097/00006231-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Artefacts caused by tissue attenuation can create problems in the interpretation of myocardial perfusion studies. This study aimed to determine if attenuation correction using the ' Hawkeye ' low-resolution X-ray computed tomography facility attached to a GE Millennium VG gamma camera reduced attenuation artefacts in our patient group. This technique offers potential advantages over isotope transmission methods of attenuation correction because of the lack of noise in the transmission images. Methods Ninety-four patients (64 males, 30 females) underwent stress/rest myocardial perfusion imaging using Tc-99m tetrofosmin (188 studies). Semi-quantitative analysis of the attenuation corrected and non-corrected perfusion images was carried out using proprietary software (Emory ECToolbox). Results No significant differences between attenuation corrected and non-corrected images were seen in the septal, lateral or apical segments. Attenuation correction produced a significant reduction in the defect scores in the inferior segment indicating the presence of attenuation artefacts. This was more marked in male patients. The incidence of attenuation artefacts; in the inferior segment increased with weight although patients of normal weight also showed attenuation artefacts. The changes in the anterior segment were more difficult to interpret particularly in females, with attenuation correction increasing the defect score in some patients. Minor degrees of mal-registration (even of 1 pixel) between emission and transmission images increased the likelihood of creating a defect. Conclusion Attenuation correction using Hawkeye is likely to improve diagnostic accuracy in men, but is less likely to be useful in women. Nucl Med Commun 26:231-237 (c) 2005 Lippincott Williams C Wilkins.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [21] Is computed tomography attenuation correction more efficient than gated single photon emission computed tomography analysis in improving the diagnostic performance of myocardial perfusion imaging in patients with low prevalence of ischemic heart disease?
    Benkiran, Meriem
    Mariano-Goulart, Denis
    Bourdon, Aurelie
    Sibille, Louis
    Ben Bouallegue, Faycal
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (01) : 69 - 77
  • [22] Attenuation correction using deep learning for brain perfusion SPECT images
    Kenta Sakaguchi
    Hayato Kaida
    Shuhei Yoshida
    Kazunari Ishii
    Annals of Nuclear Medicine, 2021, 35 : 589 - 599
  • [23] Attenuation correction using deep learning for brain perfusion SPECT images
    Sakaguchi, Kenta
    Kaida, Hayato
    Yoshida, Shuhei
    Ishii, Kazunari
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (05) : 589 - 599
  • [24] New approach for attenuation correction in SPECT images, using linear optimization
    Kamyad, A. Vahidian
    Eskandari, M. H. Noori
    Midani, M. Naji
    Saffar, M. Hajizadeh
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 8 (02): : 111 - 116
  • [25] Quantitative Evaluation of the Effect of Attenuation Correction in SPECT Images with CT-Derived Attenuation
    Tavakoli, Meysam
    Naji, Maryam
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [26] Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    Schepis, Tiziano
    Gaemperli, Oliver
    Koepfli, Pascal
    Rueegg, Christine
    Burger, Cyrill
    Leschka, Sebastian
    Desbiolles, Lotus
    Husmann, Lars
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (01) : 11 - 19
  • [27] Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT
    Tiziano Schepis
    Oliver Gaemperli
    Pascal Koepfli
    Christine Rüegg
    Cyrill Burger
    Sebastian Leschka
    Lotus Desbiolles
    Lars Husmann
    Hatem Alkadhi
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 11 - 19
  • [28] “Virtual” attenuation correction: improving stress myocardial perfusion SPECT imaging using deep learning
    Tomoe Hagio
    Alexis Poitrasson-Rivière
    Jonathan B. Moody
    Jennifer M. Renaud
    Liliana Arida-Moody
    Ravi V. Shah
    Edward P. Ficaro
    Venkatesh L. Murthy
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3140 - 3149
  • [29] Computed tomography attenuation correction improves the risk stratification accuracy of myocardial perfusion imaging
    Ou, Xiaohong
    Jiang, Lisha
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Li, Lin
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (05) : 495 - 500
  • [30] "Virtual" attenuation correction: improving stress myocardial perfusion SPECT imaging using deep learning
    Hagio, Tomoe
    Poitrasson-Riviere, Alexis
    Moody, Jonathan B.
    Renaud, Jennifer M.
    Arida-Moody, Liliana
    Shah, Ravi, V
    Ficaro, Edward P.
    Murthy, Venkatesh L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (09) : 3140 - 3149