Development of an algorithm using ultrasonography-assisted peripheral intravenous catheter placement for reducing catheter failure

被引:8
作者
Kanno, Chiho [1 ]
Murayama, Ryoko [2 ,3 ]
Abe-Doi, Mari [2 ]
Takahashi, Toshiaki [4 ]
Shintani, Yui [1 ]
Nogami, Junko [5 ]
Komiyama, Chieko [5 ]
Sanada, Hiromi [1 ,3 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Gerontol Nursing, Wound Care Management, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Adv Nursing Technol, Tokyo, Japan
[3] Univ Tokyo, Global Nursing Res Ctr, Grad Sch Med, Tokyo, Japan
[4] Univ Tokyo, Grad Sch Med, Dept Life Support Technol Molten, Tokyo, Japan
[5] Univ Tokyo Hosp, Tokyo, Japan
关键词
Algorithm; incidence; intention to treat analysis; per protocol analysis; rate of compliance; RISK-FACTORS; PHLEBITIS;
D O I
10.5582/ddt.2019.01094
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Up to 50% peripheral intravenous catheters (PIVs) are removed prematurely because of failures. Catheter failure (CF) leads to replacement and is a great concern for patients and medical staff. It is known that visualization of catheters and vessels with ultrasonography (US) during placement prevents CF. However, US is not a common technique for general nurses. In order to standardize US-assisted PIV placement techniques, an algorithm is needed. This study aimed to develop an algorithm using US-assisted PIV placement to reduce CF rate. Furthermore, to evaluate the effectiveness of the algorithm, CF rates were compared before and after intervention. A pretest-posttest study was performed. The intervention was PIV placement by 23 nurses undergoing training sessions for the algorithm. Intention to treat, per protocol analyses were applied. Logistic regression analysis was used for factor analysis. The CF rate in the pre-intervention group 35.2% (19/54) did not significantly differ from post-intervention group 33.6% (48/143) (p = 0.831), yet significantly differ from complete algorithm-use group 8.7% (2/23; p = 0.017). In factor analysis, compliance to the algorithm was significantly correlated with CF (p = 0.032). The compliance rate was low 16.1% (23/143). Algorithm compliance reduced CF by confirming appropriate catheter tip position from the insertion to the securement phase. This algorithm effectively reduced CF, however, the compliance rate was unacceptable. In order to increase the compliance rate, modified algorithm and new visualizing technology is required.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 21 条
[1]   International prevalence of the use of peripheral intravenous catheters [J].
Alexandrou, Evan ;
Ray-Barruel, Gillian ;
Carr, Peter J. ;
Frost, Steven ;
Inwood, Sheila ;
Higgins, Niall ;
Lin, Frances ;
Alberto, Laura ;
Mermel, Leonard ;
Rickard, Claire M. .
JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (08) :530-533
[2]  
Anderson J., 2016, J Vasc Access, V21, P158, DOI [10.1016/j.java.2016.03.007, DOI 10.1016/J.JAVA.2016.03.007]
[3]  
ANNING S T, 1957, Med Hist, V1, P28
[4]   Ultrasound-Guided Peripheral Intravenous Catheter Training Results in Physician-Level Success for Emergency Department Technicians [J].
Duran-Gehring, Petra ;
Bryant, Laurie ;
Reynolds, Jennifer A. ;
Aldridge, Petra ;
Kalynych, Colleen J. ;
Guirgis, Faheem W. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (11) :2343-2352
[5]   Toward improved implementation of evidence-based clinical algorithms: Clinical practice guidelines, clinical decision rules, and clinical pathways [J].
Gaddis, Gary M. ;
Greenwald, Peter ;
Huckson, Sue .
ACADEMIC EMERGENCY MEDICINE, 2007, 14 (11) :1015-1022
[6]  
Gorski L, 2016, INFUSION THERAPY STA, P95
[7]   Infiltration and extravasation - Preventing a complication of IV catheterization [J].
Hadaway, Lynn .
AMERICAN JOURNAL OF NURSING, 2007, 107 (08) :64-72
[8]   Accepted but Unacceptable: Peripheral IV Catheter Failure [J].
Helm, Robert E. ;
Klausner, Jeffrey D. ;
Klemperer, John D. ;
Flint, Lori M. ;
Huang, Emily .
JOURNAL OF INFUSION NURSING, 2015, 38 (03) :189-203
[9]  
Karadag A, 2000, J Intraven Nurs, V23, P158
[10]   Infusion phlebitis in patients with acute pneumonia - A prospective study [J].
Monreal, M ;
Quilez, F ;
Rey-Joly, C ;
Rodriguez, S ;
Sopena, N ;
Neira, C ;
Roca, J .
CHEST, 1999, 115 (06) :1576-1580