Design and performance studies of a hybrid voltage regulator with improved energy efficiency

被引:2
作者
Panguloori, R. B. [1 ]
Kastha, D. [1 ]
Patra, A. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Kharagpur 721302, W Bengal, India
关键词
BUCK CONVERTER; TRANSIENT;
D O I
10.1049/iet-pel.2010.0001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transformer coupling in high step-down ratio voltage regulators (VR) improves their efficiency by extending the duty cycle, but re wits in poor dynamic performance because of their low inductor current slew rate and the leakage inductance of the transformer. Hybrid VR use an auxiliary buck converter in parallel with the main converter during load transients to improve the dynamic performance of the VR. The dynamic power loss in the auxiliary buck converter, however, severely affects the energy efficiency of the VR with increasing frequency of the load transients. This study presents the design and performance of a new control circuit proposed to minimise the dynamic power loss in the auxiliary buck converter of a hybrid voltage regulator consisting of an isolated full-bridge current doubler rectifier converter in parallel with an auxiliary buck converter. The results obtained from simulation and experimentation on a 9-19 V input, 1 V/30 A output, 500 kHz hybrid voltage regulator. designed according to the proposed method, show that the proposed control scheme significantly improves both the dynamic performance and the energy efficiency of the VR.
引用
收藏
页码:915 / 924
页数:10
相关论文
共 27 条
  • [1] Transient response improvement in dc-dc converters using output capacitor current for faster transient detection
    Abdel-Rahman, Osama
    Batarseh, Issa
    [J]. 2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 157 - 160
  • [2] Single shot transient suppressor (SSTS) for high current high slew rate microprocessor
    Amoroso, L
    Donati, M
    Zhou, XW
    Lee, FC
    [J]. APEC'99: FOURTEENTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, CONFERENCE PROCEEDINGS, VOLS 1 & 2, 1999, : 284 - 288
  • [3] The fast response double buck DC-DC converter (FRDB):: Operation and output filter influence
    Barrado, A
    Lázaro, A
    Vázquez, R
    Salas, V
    Olías, E
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) : 1261 - 1270
  • [4] Consoli A, 2001, IEEE POWER ELECTRON, P339, DOI 10.1109/PESC.2001.954043
  • [5] DAN M, 2001, TI SEM 1400 TOP 5 IR
  • [6] ERIC M, 2009, P IEEE APEC, P1367
  • [7] GUO J, 2003, P IEEE INTELEC, P98
  • [8] JIA W, 2004, P IEEE APEC, V2, P1294
  • [9] JIA W, 2003, P IEEE PESC, V4, P1599
  • [10] Kutkut NH, 1997, INTELEC 97 - 19TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, PROCEEDINGS, P344, DOI 10.1109/INTLEC.1997.645910