Fluorescent immunoliposomal nanovesicles for rapid multi-well immuno-biosensing of histamine in fish samples

被引:20
作者
Bajpai, Vivek K. [1 ]
Oh, CheolWoo [2 ]
Khan, Imran [2 ]
Haldorai, Yuvaraj [3 ]
Gandhi, Sonu [4 ]
Lee, Hoomin [2 ]
Song, Xinjie [5 ]
Kim, Myunghee [5 ]
Upadhyay, Ashutosh [6 ]
Chen, Lei [7 ]
Huh, Yun Suk [2 ]
Han, Young-Kyu [1 ]
Shukla, Shruti [6 ]
机构
[1] Dongguk Univ Seoul, Dept Energy & Mat Engn, 30 Pildong Ro 1 Gil, Seoul 04620, South Korea
[2] Inha Univ, BSRC, Dept Biol Engn, 100 Inha Ro, Incheon 22212, South Korea
[3] Bharathiar Univ, Dept Nanosci & Technol, Coimbatore 641046, Tamil Nadu, India
[4] DBT NIAB, Hyderabad 500032, Telangana, India
[5] Yeungnam Univ, Dept Food Sci & Technol, Gyeongsang Si, South Korea
[6] NIFTEM, Dept Food Sci & Technol, Sonipat 131028, Haryana, India
[7] Fujian Agr & Forestry Univ, Coll Food Sci, Fuzhou 350002, Fujian, Peoples R China
基金
新加坡国家研究基金会;
关键词
double layered; Liposome immunosensor; Signal amplifiers; Fluorescence quenching; Histamine toxicity; BIOGENIC-AMINES; SENSITIVE DETECTION; ELECTROCHEMICAL IMMUNOSENSOR; SILICA NANOPARTICLES; QUANTUM DOTS; ASSAY; GOLD; ELECTRODES; SEPARATION; LIPOSOME;
D O I
10.1016/j.chemosphere.2019.125404
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Scombroid poisoning in fish-based and other food products has raised concerns due to toxicity outbreaks and incidences associated with histamine, thus measuring the amount of histamine toxic molecule is considered crucial quality indicator of food safety and human health. In this study, liposome-based measurement of histamine was performed via rupturing mechanism of sulforhodamine B dye encapsulated anti-histamine antibody conjugated liposomal nanovesicles. The immunosensing ability of immuno-liposomal format was assessed by monitoring the fluorescence at excitation/emission wave-length of 550/585 nm. Immuno-liposomal format assays were considered, one based on single wash procedure (Method 1), which had a detection limit of 10 ppb and quantification limit 15-80 ppb. While Method 2 based on one-by-one wash procedure had a detection limit of 2-3 ppb and quantification limit 8.5 ppb-200 ppm that required 2 h 30 min to perform. In view of better quantification limit, Method 2 was chosen for further tests required to validate its applicability in real samples. The feasibility of Method 2 was reconfirmed in fresh mackerel fish, and canned fish (tuna and salmon) with a similar detection limits but with low amplified fluorescence signals and sufficient levels of histamine recovery from fresh mackerel (73.50-99.98%), canned tuna (79.08-103.74%) and salmon (74.56-99.02%). The specificity and method accuracy were expressed as % CV in the range 5.34%-8.48%. Overall, the developed multi-well sensing system (Method 2) showed satisfactory specificity, cost effectiveness, rapidity, and stability for monitoring histamine toxicity as a practical food diagnostic device. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 57 条
[1]   Label-free histamine detection with nanofluidic diodes through metal ion displacement mechanism [J].
Ali, Mubarak ;
Ramirez, Patricio ;
Duznovic, Ivana ;
Nasir, Saima ;
Mafe, Salvador ;
Ensinger, Wolfgang .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2017, 150 :201-208
[2]   Determination of biogenic diamines with a vaporisation derivatisation approach using solid-phase microextraction gas chromatography-mass spectrometry [J].
Awan, M. Ali ;
Fleet, I. ;
Thomas, C. L. Paul .
FOOD CHEMISTRY, 2008, 111 (02) :462-468
[3]   Use of liposomal amplifiers in total internal reflection fluorescence fiber-optic biosensors for protein detection [J].
Chang, Ying-Feng ;
Fu, Chen ;
Chen, Yi-Ting ;
Jou, Amily Fang-Ju ;
Chen, Chii-Chang ;
Chou, Chien ;
Ho, Ja-an Annie .
BIOSENSORS & BIOELECTRONICS, 2016, 77 :1201-1207
[4]   Zinc Oxide Tetrapods Based Biohybrid Interface for Voltammetric Sensing of Helicobacter pylori [J].
Chauhan, Nidhi ;
Gupta, Shaivya ;
Avasthi, Devesh K. ;
Adelung, Rainer ;
Mishra, Yogendra Kumar ;
Jain, Utkarsh .
ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (36) :30631-30639
[5]   Portable amperometric immunosensor for histamine detection using Prussian blue-chitosan-gold nanoparticle nanocomposite films [J].
Dong, Xiu-Xiu ;
Yang, Jin-Yi ;
Luo, Lin ;
Zhang, Yi-Feng ;
Mao, Chuanbin ;
Sun, Yuan-Ming ;
Lei, Hong-Tao ;
Shen, Yu-Dong ;
Beier, Ross C. ;
Xu, Zhen-Lin .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :305-309
[6]   Magnetic Electrochemical Sensing Platform for Biomonitoring of Exposure to Organophosphorus Pesticides and Nerve Agents Based on Simultaneous Measurement of Total Enzyme Amount and Enzyme Activity [J].
Du, Dan ;
Wang, Jun ;
Wang, Limin ;
Lu, Donglai ;
Smith, Jordan N. ;
Timchalk, Charles ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2011, 83 (10) :3770-3777
[7]   Liposomes in analyses [J].
Edwards, KA ;
Baeumner, AJ .
TALANTA, 2006, 68 (05) :1421-1431
[8]  
EFSA, 2011, EFSA J, V9, P2393, DOI DOI 10.2903/j.efsa.2011.2393
[9]   Recent analytical approaches to the analysis of biogenic amines in food samples [J].
Erim, F. Bedia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 52 :239-247
[10]  
FAO, 2012, FOOD AGR ORG COD AL