Single Drop Electroanalysis and Interfacial Interactions: Sensitivity versus Limit of Detection

被引:4
作者
Walgama, Charuksha [1 ]
Gallman, Matthew [1 ]
Krishnan, Sadagopan [1 ]
机构
[1] Oklahoma State Univ, Dept Chem, Stillwater, OK 74078 USA
基金
美国国家卫生研究院;
关键词
Single drop analysis; Interfacial interactions; Sensitivity; Detection limit; Sensor surface; Real samples; SCREEN-PRINTED ELECTRODES; ELECTROCHEMICAL SENSORS; GLUCOSE SENSORS; ASCORBIC-ACID; URIC-ACID; GRAPHENE; MICROFLUIDICS; ACETAMINOPHEN; BIOSENSOR; DOPAMINE;
D O I
10.1002/elan.201600271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report single drop electroanalytical measurements of pharmaceutically and biologically relevant compounds using screen printed electrodes (SPEs) modified with carboxylated multiwalled carbon nanotubes (MWCNT-COOH) as the sensor surface. Acetaminophen, nicotine, ascorbic acid, and nicotinamide adenine dinucleotide reduced form (NADH) were detected in a single drop of solution. We show that combined polar and nonpolar interactions of analytes with -COOH functional groups and large surface area of MWCNT, respectively, allow highly sensitive analyte detection with wide dynamic range. Smaller analytes can bind to a significantly greater number of sensor sites than the bulkier analytes and offer better detection sensitivity. Results suggest that sensitivity is controlled by predominant nonpolar interactions that an analyte can undergo with the MWCNT-COOH SPE sensor surface, whereas limit of detection is controlled by the extent of polar interactions between an analyte and the sensor surface, facilitating interfacial charge transport and an electrochemical signal output. Furthermore, a combination of polar and nonpolar analyte interactions with the sensor surface shows a synergistic effect on sensitivity and detection limit. This could be a likely reason for why sensitivity does not need to always correlate with lower detection limits as variations in the interfacial interactions are critical. Application of the designed single drop method to real samples was validated by estimating the amounts of acetaminophen, nicotine, ascorbic acid, and NADH in commercially available pharmaceuticals with excellent recovery.
引用
收藏
页码:2791 / 2796
页数:6
相关论文
共 31 条
  • [1] Study of chemistry in droplets with net charge before and after Coulomb explosion: Ion-induced nucleation in solution and implications for ion production in an electrospray
    Bakhoum, SFW
    Agnes, GR
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (10) : 3189 - 3197
  • [2] Electrochemistry of immobilised redox droplets: Concepts and applications
    Banks, CE
    Davies, TJ
    Evans, RG
    Hignett, G
    Wain, AJ
    Lawrence, NS
    Wadhawan, JD
    Marken, F
    Compton, RG
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2003, 5 (19) : 4053 - 4069
  • [3] Brad A.J., 2000, Electrochemical Methods: Fundamentals and Applications, V2nd
  • [4] Recent advances in electrochemical glucose biosensors: a review
    Chen, Chao
    Xie, Qingji
    Yang, Dawei
    Xiao, Hualing
    Fu, Yingchun
    Tan, Yueming
    Yao, Shouzhuo
    [J]. RSC ADVANCES, 2013, 3 (14): : 4473 - 4491
  • [5] A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood
    Chen, JC
    Chung, HH
    Hsu, CT
    Tsai, DM
    Kumar, AS
    Zen, JM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) : 364 - 369
  • [6] Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes
    Fanjul-Bolado, Pablo
    Jose Lamas-Ardisana, Pedro
    Hernandez-Santos, David
    Costa-Garcia, Agustin
    [J]. ANALYTICA CHIMICA ACTA, 2009, 638 (02) : 133 - 138
  • [7] Fernandez C, 2015, INT J ELECTROCHEM SC, V10, P7440
  • [8] Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring
    Hayat, Akhtar
    Marty, Jean Louis
    [J]. SENSORS, 2014, 14 (06): : 10432 - 10453
  • [9] Electrochemical glucose sensors and their applications in diabetes management
    Heller, Adam
    Feldman, Ben
    [J]. CHEMICAL REVIEWS, 2008, 108 (07) : 2482 - 2505
  • [10] Metallic Free Carbon Nanotube Cluster Modified Screen Printed Electrodes for the Sensing of Nicotine in Artificial Saliva
    Highton, Louise
    Kadara, Rashid O.
    Jenkinson, Norman
    Riehl, Bill Logan
    Banks, Craig E.
    [J]. ELECTROANALYSIS, 2009, 21 (21) : 2387 - 2389