Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study

被引:219
作者
Bongartz, Tim [1 ]
Glazebrook, Katrina N. [2 ]
Kavros, Steven J. [3 ]
Murthy, Naveen S. [2 ]
Merry, Stephen P. [4 ]
Franz, Walter B., III [4 ]
Michet, Clement J. [1 ]
Veetil, Barath M. Akkara [1 ]
Davis, John M., III [1 ]
Mason, Thomas G., II [1 ]
Warrington, Kenneth J. [1 ]
Ytterberg, Steven R. [1 ]
Matteson, Eric L. [1 ]
Crowson, Cynthia S. [5 ]
Leng, Shuai [2 ]
McCollough, Cynthia H. [2 ]
机构
[1] Mayo Clin, Dept Internal Med, Div Rheumatol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Family Med, Rochester, MN 55905 USA
[5] Mayo Clin, Dept Hlth Sci Res, Div Biomed Stat & Informat, Rochester, MN 55905 USA
关键词
Gout; Dual energy CT scanning; accuracy; URIC-ACID; COMPUTED-TOMOGRAPHY; ARTHRITIS; DIFFERENTIATION; IDENTIFICATION; EXPERIENCE; CRYSTALS;
D O I
10.1136/annrheumdis-2013-205095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). Methods Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. Results The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). Conclusions DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals.
引用
收藏
页码:1072 / 1077
页数:6
相关论文
共 19 条
[1]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[2]   Dual energy CT in gout: a prospective validation study [J].
Choi, Hyon K. ;
Burns, Lindsay C. ;
Shojania, Kamran ;
Koenig, Nicole ;
Reid, Graham ;
Abufayyah, Mohammed ;
Law, Genevieve ;
Kydd, Alison S. ;
Ouellette, Hugue ;
Nicolaou, Savvas .
ANNALS OF THE RHEUMATIC DISEASES, 2012, 71 (09) :1466-1471
[3]   Uric acid is a danger signal of increasing risk for osteoarthritis through inflammasome activation [J].
Denoble, Anna E. ;
Huffman, Kim M. ;
Stabler, Thomas V. ;
Kelly, Susan J. ;
Hershfield, Michael S. ;
McDaniel, Gary E. ;
Coleman, R. Edward ;
Kraus, Virginia B. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (05) :2088-2093
[4]   Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout [J].
Desai, Madhura A. ;
Peterson, Jeffrey J. ;
Garner, Hillary Warren ;
Kransdorf, Mark J. .
RADIOGRAPHICS, 2011, 31 (05) :1365-1375
[5]   Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation [J].
Glazebrook, Katrina N. ;
Guimaraes, Luis S. ;
Murthy, Naveen S. ;
Black, David F. ;
Bongartz, Tim ;
Manek, Nisha J. ;
Leng, Shuai ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOLOGY, 2011, 261 (02) :516-524
[6]   Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[7]   Dual-energy computed tomography compared with ultrasound in the diagnosis of gout [J].
Gruber, Michael ;
Bodner, Gerd ;
Rath, Eva ;
Supp, Gabriela ;
Weber, Michael ;
Schueller-Weidekamm, Claudia .
RHEUMATOLOGY, 2014, 53 (01) :173-179
[8]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[9]   The role of uric acid and other crystals in osteoarthritis [J].
Nowatzky J. ;
Howard R. ;
Pillinger M.H. ;
Krasnokutsky S. .
Current Rheumatology Reports, 2010, 12 (2) :142-148
[10]   How is gout managed in primary care? A review of current practice and proposed guidelines [J].
Pal, B ;
Foxall, M ;
Dysart, T ;
Carey, F ;
Whittaker, M .
CLINICAL RHEUMATOLOGY, 2000, 19 (01) :21-25