Biaxial mechanical modeling of the small intestine

被引:79
作者
Bellini, Chiara [3 ]
Glass, Paul [4 ]
Sitti, Metin [4 ,5 ]
Di Martino, Elena S. [1 ,2 ]
机构
[1] Univ Calgary, Dept Civil Engn, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Ctr Bioengn Res & Educ, Calgary, AB T2N 1N4, Canada
[3] Univ Calgary, Grad Program Biomed Engn, Calgary, AB T2N 1N4, Canada
[4] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
[5] Carnegie Mellon Univ, Dept Mech Engn, Pittsburgh, PA 15213 USA
关键词
Small intestine; Planar biaxial tensile test; Constitutive modeling; Finite element method; Capsule endoscope; BIOMECHANICAL PROPERTIES; CAPSULE ENDOSCOPY; COLLAGEN-FIBERS; ENTEROSCOPY; BEHAVIOR;
D O I
10.1016/j.jmbbm.2011.05.030
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Capsule endoscopes are pill-size devices provided with a camera that capture images of the small intestine from inside the body after being ingested by a patient. The interaction between intestinal tissue and capsule endoscopes needs to be investigated to optimize capsule design while preventing tissue damage. To that purpose, a constitutive model that can reliably predict the mechanical response of the intestinal tissue under complex mechanical loading is required. This paper describes the development and numerical validation of a phenomenological constitutive model for the porcine duodenum, jejunum and ileum. Parameters characterizing the mechanical behavior of the material were estimated from planar biaxial test data, where intestinal tissue specimens were simultaneously loaded along the circumferential and longitudinal directions. Specimen-specific Fung constitutive models were able to accurately predict the planar stress-strain behavior of the tested samples under a wide range of loading conditions. To increase model generality, average anisotropic constitutive relationships were also generated for each tissue region by fitting average stress-strain curves to the Fung potential. Due to the observed variability in the direction of maximum stiffness, the average Fung models were less anisotropic than the specimen-specific models. Hence, average isotropic models in the Neo-Hookean and Mooney-Rivlin forms were attempted, but they could not adequately describe the degree of nonlinearity in the tissue. Values of the R-2 for the nonlinear regressions were 0.17, 0.44 and 0.93 for the average Neo-Hookean, Mooney-Rivlin and Fung models, respectively. Average models were successfully implemented into FORTRAN routines and used to simulate capsule deployment with a finite element method analysis. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1727 / 1740
页数:14
相关论文
共 42 条
[1]   A single-center experience of 260 consecutive patients undergoing capsule endoscopy for obscure gastrointestinal bleeding [J].
Carey, Elizabeth J. ;
Leighton, Jonathan A. ;
Heigh, Russell I. ;
Shiff, Arthur D. ;
Sharma, Virender K. ;
Post, Janice K. ;
Fleischer, David E. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (01) :89-95
[2]   Controlled navigation of endoscopic capsules: Concept and preliminary experimental investigations [J].
Carpi, Federico ;
Galbiati, Stefano ;
Carpi, Angelo .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (11) :2028-2036
[3]  
Cheung E, 2005, IEEE ASME INT C ADV, P551
[4]   Capsule endoscopy vs. push enteroscopy and enteroclysis in suspected small-bowel Crohn's disease [J].
Chong, AKH ;
Taylor, A ;
Miller, A ;
Hennessy, O ;
Connell, W ;
Desmond, P .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (02) :255-261
[5]   Hyperelastic Model of Anisotropic Fiber Reinforcements within Intestinal Walls for Applications in Medical Robotics [J].
Ciarletta, P. ;
Dario, P. ;
Tendick, F. ;
Micera, S. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2009, 28 (10) :1279-1288
[6]   Modeling and experimental validation of the locomotion of endoscopic robots in the colon [J].
Dario, P ;
Ciarletta, P ;
Menciassi, A ;
Kim, B .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2004, 23 (4-5) :549-556
[7]   Biomechanical properties of ruptured versus electively repaired abdominal aortic aneurysm wall tissue [J].
Di Martino, ES ;
Bohra, A ;
Vande Geest, JP ;
Gupta, N ;
Makaroun, MS ;
Vorp, DA .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (03) :570-576
[8]   Effect of re-feeding after starvation on biomechanical properties in rat small intestine [J].
Dou, YL ;
Gregersen, S ;
Zhao, JB ;
Zhuang, FY ;
Gregersen, H .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (08) :557-566
[9]   Mechanical properties of the human gastrointestinal tract [J].
Egorov, VI ;
Schastlivtsev, IV ;
Prut, EV ;
Baranov, AO ;
Turusov, RA .
JOURNAL OF BIOMECHANICS, 2002, 35 (10) :1417-1425
[10]   Convex Fung-type potentials for biological tissues [J].
Federico, Salvatore ;
Grillo, Alfio ;
Giaquinta, Gaetano ;
Herzog, Walter .
MECCANICA, 2008, 43 (03) :279-288