Simple, fast and reliable perfusion monitoring of microvascular flaps

被引:27
作者
Meier, J. K. [2 ]
Prantl, L. [1 ]
Mueller, S. [2 ]
Moralis, A. [2 ]
Liebsch, G. [3 ]
Gosau, M. [2 ]
机构
[1] Univ Med Ctr, Ctr Plast Hand & Reconstruct Surg, D-93042 Regensburg, Germany
[2] Univ Med Ctr, Dept Craniomaxillofacial Surg, D-93042 Regensburg, Germany
[3] PreSens GmbH, Regensburg, Germany
关键词
Free flap; microvascular; pO(2) imaging; fluorescent optical sensor; TISSUE TRANSFER; OXYGEN FLUX; HEAD; NECK; RECONSTRUCTION; COMPLICATIONS; THROMBOSIS;
D O I
10.3233/CH-2011-1439
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Free tissue transfer in head and neck reconstructions has a very high success rate, but thrombotic vessel occlusion is still a serious complication occurring in up to 10% of all cases. Thus, a simple, fast and reliable monitoring system for free flaps would be of advantage. Objective: The aim of this study was to investigate whether free flap monitoring by measuring perfusion-dependent parameters is a suitable method for discovering vessel thrombosis in free flaps. Methods: 10 patients requiring tissue reconstruction after tumour surgery or because of chronic wounds were included in this study. 10 microvascular flaps were harvested and transplanted. Perfusion was determined by measuring a fluorescent oxygen sensor foil covering the flap's skin surface by means of a USB-handheld fluorescence microscope prototype. The sensor contained an oxygen reservoir which was consumed by the tissue corresponding to the perfusion status of the flap. Measurements were done before explantation, after successful anastomosis and 1 day after surgery. Results: Clinically well-perfused grafts showed slope values between 0.07 and 0.27 (mean: 0.18+/-0.07), and clinically poorly perfused grafts showed slope values between 0.35 and 0.75 (mean: 0.52+/-0.19). In the present study, we used a threshold slope value of 0.3 for differentiating between well-perfused and poorly perfused flaps. Conclusion: Flap monitoring via oxygen imaging by means of fluorescent sensor foils appears to be a fast, non-invasive, cost-effective and thus suitable method for analyzing flap perfusion with the additional advantage of aiding decision making on flap revision.
引用
收藏
页码:13 / 24
页数:12
相关论文
共 28 条
[11]   Is the Use of Intraoperative Heparin Safe? [J].
Chen, Constance M. ;
Ashjian, Peter ;
Disa, Joseph J. ;
Cordeiro, Peter G. ;
Pusic, Andrea L. ;
Mehrara, Babak J. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (03) :49E-53E
[12]   Head and neck reconstruction with free flaps: a report on 213 cases [J].
Dassonville, Olivier ;
Poissonnet, Gilles ;
Chamorey, Emmanuel ;
Vallicioni, Jacques ;
Demard, Francois ;
Santini, Joseph ;
Lecoq, Mayeul ;
Converset, Sophie ;
Mahdyoun, Pouya ;
Bozec, Alexandre .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2008, 265 (01) :85-95
[13]   Venous thrombosis after microvascular free-tissue transfer in head and neck cancer reconstruction [J].
Fukuiwa, Tatsuya ;
Nishimoto, Kengo ;
Hayashi, Tamon ;
Kurono, Yuichi .
AURIS NASUS LARYNX, 2008, 35 (03) :390-396
[14]   Transcutaneous pO2 measurement during tourniquet-induced venous occlusion using dynamic phosphorescence imaging [J].
Geis, S. ;
Babilas, P. ;
Schreml, S. ;
Angele, P. ;
Nerlich, M. ;
Jung, E. M. ;
Prantl, L. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2008, 40 (04) :249-258
[15]   Oxygen flux fluorescence lifetime imaging [J].
Hartmann, P ;
Ziegler, W ;
Holst, G ;
Lubbers, DW .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :110-115
[16]   Free flap reconstruction of the head and neck: Analysis of 241 cases [J].
Haughey, BH ;
Wilson, E ;
Kluwe, L ;
Piccirillo, J ;
Fredrickson, J ;
Sessions, D ;
Spector, G .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2001, 125 (01) :10-17
[17]   A prospective study of microvascular free-flap surgery and outcome [J].
Khouri, RK ;
Cooley, BC ;
Kunselman, AR ;
Landis, JR ;
Yeramian, P ;
Ingram, D ;
Natarajan, N ;
Benes, CO ;
Wallemark, C .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (03) :711-721
[18]   Management of flaps with compromised venous outflow in head and neck microsurgical reconstruction [J].
Kubo, T ;
Yano, K ;
Hosokawa, K .
MICROSURGERY, 2002, 22 (08) :391-395
[19]   Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing [J].
Liebsch, G ;
Klimant, I ;
Krause, C ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4354-4363
[20]   Tissue Oximetry Monitoring in Microsurgical Breast Reconstruction Decreases Flap Loss and Improves Rate of Flap Salvage [J].
Lin, Samuel J. ;
Nguyen, Minh-Doan ;
Chen, Chen ;
Colakoglu, Salih ;
Curtis, Michael S. ;
Tobias, Adam M. ;
Lee, Bernard T. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 127 (03) :1080-1085