Vial freeze-drying, part 1: New insights into heat transfer characteristics of tubing and molded vials

被引:37
作者
Hibler, Susanne [1 ]
Wagner, Christophe [2 ]
Gieseler, Henning [1 ]
机构
[1] Univ Erlangen Nurnberg, Freeze Drying Focus Grp, Div Pharmaceut, D-91058 Erlangen, Germany
[2] SGD SA, F-80350 Mers Les Bains, France
关键词
freeze-drying; lyophilization; drying; polymers; glass; sublimation test; heat transfer; vial heat transfer coefficient; primary packaging; MANOMETRIC TEMPERATURE-MEASUREMENT; LASER ABSORPTION-SPECTROSCOPY; PRODUCT TEMPERATURE; PROTEIN FORMULATIONS; TRANSFER PARAMETERS; RAPID-DETERMINATION; SUBLIMATION RATES; PRACTICAL ADVICE; DESIGN; MASS;
D O I
10.1002/jps.23004
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
In order to optimize a freeze-drying cycle, information regarding the heat transfer characteristics of the container system is imperative. Two most recently developed tubing (TopLyo (TM)) and molded (EasyLyo (TM)) vial designs were compared with a standard serum tubing and molded vial, a polymer vial (TopPac (TM)), and an amber molded EasyLyo (TM). In addition, the impact of methodology on the determination of reliable vial heat transfer coefficient (K-v) data is examined in detail. All K(v)s were gravimetrically determined by sublimation tests with pure water at 50, 100, 200, and 400 mTorr. In contrast to the traditional assumption that molded vials exhibit inefficient heat transfer characteristics, these vials showed a very similar performance compared with their serum tubing counterparts in the relevant pressure range for freeze-drying. At 100 mTorr, the TopLyo (TM) center vials show only 4% higher Kv values than the EasyLyo (TM) center vials. All glass vials outmatch the polymer vial in terms of heat transfer, up to 30% elevated heat transfer for the TopLyo (TM) center vials at 400 mTorr. Sublimation tests have demonstrated to be a valuable tool to investigate the heat transfer characteristics of vials, but results are dependent on methodology. New developments in molded vial manufacturing lead to improved heat transfer performance. (c) 2011 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 101:11891201, 2012
引用
收藏
页码:1189 / 1201
页数:13
相关论文
共 23 条
[1]  
Bauer EJ, 2009, CONTAINER FABRICATIO, P295
[2]   Heat transfer in vial lyophilization [J].
Brülls, M ;
Rasmuson, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 246 (1-2) :1-16
[3]   Statistical evaluation of vial design features that influence sublimation rates during primary drying [J].
Cannon, A ;
Shemeley, K .
PHARMACEUTICAL RESEARCH, 2004, 21 (03) :536-542
[4]   Rational design of stable lyophilized protein formulations: Some practical advice [J].
Carpenter, JF ;
Pikal, MJ ;
Chang, BS ;
Randolph, TW .
PHARMACEUTICAL RESEARCH, 1997, 14 (08) :969-975
[5]   Optimization of the freeze-drying cycle: A new model for pressure rise analysis [J].
Chouvenc, P ;
Vessot, S ;
Andrieu, J ;
Vacus, P .
DRYING TECHNOLOGY, 2004, 22 (07) :1577-1601
[6]   Use of manometric temperature measurement (MTM) and SMART™ freeze dryer technology for development of an optimized freeze-drying cycle [J].
Gieseler, Henning ;
Kramer, Tony ;
Pikal, Michael J. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (12) :3402-3418
[7]  
Hibler S, 2010, EUR PHARM REV, V15, P10
[8]  
Hottot A, 2005, PDA J PHARM SCI TECH, V59, P138
[9]   Use of Manometric Temperature Measurements (MTM) to Characterize the Freeze-Drying Behavior of Amorphous Protein Formulations [J].
Johnson, Robert E. ;
Oldroyd, Megan E. ;
Ahmed, Saleem S. ;
Gieseler, Henning ;
Lewis, Lavinia M. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (06) :2863-2873
[10]   Rapid Determination of Vial Heat Transfer Parameters Using Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Response to Step-Changes in Pressure Set-Point During Freeze-Drying [J].
Kuu, Wei Y. ;
Nail, Steven L. ;
Sacha, Gregory .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 98 (03) :1136-1154