Simulation and experimental results on monolithic CdZnTe gamma-ray detectors

被引:0
|
作者
d'Aillon, EG [1 ]
Gentet, MC [1 ]
Montémont, G [1 ]
Rustique, J [1 ]
Verger, L [1 ]
机构
[1] CEA Grenoble, LETI, CEA Rech Technol, F-38054 Grenoble, France
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
gamma-ray detector; CZT; CdTe : Cl; ULYSSE simulation; correction methods; charge sharing;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Monolithic CdZnTe detectors are promising for medical and small animal imaging because of a good energy resolution that allows both multi-drug diagnostic and scatter event rejection. Optimizations of electrode geometry and detector thickness are used to improve detection efficiency as well as energy resolution for various material transport properties, with the ULYSSE simulator. As an example, for a 5 mm thick detector with (mu tau)(e) = 3. 10(-3) cm(2)/V, a 1.8 mm pitch gives the best simulated energy resolution on the conventional spectrum at 122 keV. Nevertheless, even with an optimized detector, electronic correction methods contribute to reduce tailing. Correction using cathode and anode signals have been tested with HPBM CdZnTe and THM CdTe:Cl detectors. The appropriate method to correct energy seems to depend on material. This paper also presents experimental results on charge sharing and loss.
引用
收藏
页码:4451 / 4455
页数:5
相关论文
共 50 条
  • [1] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3096 - 3102
  • [2] Charge sharing on monolithic CdZnTe gamma-ray detectors:: A simulation study
    d'Aillon, Eric Gros
    Tabary, Joachim
    Gliere, Alain
    Verger, Loick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 124 - 127
  • [3] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [4] High-Efficiency CdZnTe Gamma-Ray Detectors
    Bolotnikov, A. E.
    Ackley, K.
    Camarda, G. S.
    Cui, Y.
    Eger, J. F.
    De Geronimo, G.
    Finfrock, C.
    Fried, J.
    Hossain, A.
    Lee, W.
    Prokesch, M.
    Petryk, M.
    Reiber, J. L.
    Roy, U.
    Vernon, E.
    Yang, G.
    James, R. B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (06) : 3193 - 3198
  • [5] Simulation of CdZnTe gamma-ray spectrometer response
    Glière, A
    Rosaz, M
    Verger, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 250 - 254
  • [6] CdTe and CdZnTe crystals for room temperature gamma-ray detectors
    Franc, J
    Höschl, P
    Belas, E
    Grill, R
    Hlídek, P
    Moravec, P
    Bok, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 146 - 151
  • [7] The energy dependence of the sensitivity for planar CdZnTe gamma-ray detectors
    Zakharchenko, Alexandr A.
    Skrypnyk, Anna I.
    Khazhmuradov, Manap A.
    Rybka, Alexandr V.
    Kutny, Vladimir E.
    Fochuk, Petro M.
    Sklyarchuk, Valery M.
    Bolotnikov, A. E.
    James, R. B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [8] Transport properties and spectrometric performances of CdZnTe gamma-ray detectors
    Zakharchenko, Alexandr A.
    Rybka, Alexandr V.
    Kutny, Vladimir E.
    Skrypnyk, Anna I.
    Khazhmuradov, Manap A.
    Fochuk, Petro M.
    Bolotnikov, Aleksey E.
    James, Ralph B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIV, 2012, 8507
  • [9] Performance of CdZnTe coplanar-grid gamma-ray detectors
    Luke, PN
    Eissler, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1481 - 1486
  • [10] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 297 - 309