Influences of perceived control on thermal comfort and energy use in buildings

被引:89
作者
Yun, Geun Young [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, South Korea
基金
新加坡国家研究基金会;
关键词
Low energy building; Perceived control; Thermal comfort; OCCUPANT BEHAVIOR; ADAPTIVE COMFORT; PERSONAL CONTROL; MODELS; ADAPTATION; OFFICES; SYSTEMS; FIELD; CONSUMPTION; PATTERNS;
D O I
10.1016/j.enbuild.2017.10.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study explores the role of occupants' perceived control in their subjective evaluation of thermal environments and its effects on cooling energy consumption in air-conditioned buildings. Seven air-conditioned buildings with operable windows were selected for field measurements in South Korea. The monitoring data give evidence of a statistically significant relationship between perceived control and the thermal sensations of occupants. The summer comfort temperature for the group with a high level of perceived control over the thermal environment was 0.9 degrees C higher than that for the group with low perceived control. Also, the high perceived control group felt cooler in summer than the low perceived control group. After identifying the effect of perceived control on comfort temperature, dynamic building energy simulations were conducted using EnergyPlus to examine the influence of perceived control on building energy consumption. The simulation results show that increasing occupants' perceived level of control over the thermal environment could reduce cooling energy consumption by 9% without sacrificing the thermal comfort of the occupants. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:822 / 830
页数:9
相关论文
共 62 条
[21]  
Fanger PO, 2002, ENERG BUILDINGS, V34, P533
[22]   On the behaviour and adaptation of office occupants [J].
Haldi, Frederic ;
Robinson, Darren .
BUILDING AND ENVIRONMENT, 2008, 43 (12) :2163-2177
[23]   Thermo-specific self-efficacy (specSE) in relation to perceived comfort and control [J].
Hawighorst, Maren ;
Schweiker, Marcel ;
Wagner, Andreas .
BUILDING AND ENVIRONMENT, 2016, 102 :193-206
[24]   Thermal comfort of sellers with a kind of traditional personal heating device (Huotong) in marketplace in winter [J].
He, Yingdong ;
Li, Nianping ;
Zhang, Wenjie ;
Zhou, Linxuan .
BUILDING AND ENVIRONMENT, 2016, 106 :219-228
[25]   Advances in research and applications of energy-related occupant behavior in buildings [J].
Hong, Tianzhen ;
Taylor-Lange, Sarah C. ;
D'Oca, Simona ;
Yan, Da ;
Corgnati, Stefano P. .
ENERGY AND BUILDINGS, 2016, 116 :694-702
[26]  
Joanes DN, 1998, J ROY STAT SOC D-STA, V47, P183
[27]   Development of the adaptive PMV model for improving prediction performances [J].
Kim, Jeong Tai ;
Lim, Ji Hyun ;
Cho, Sun Ho ;
Yun, Geun Young .
ENERGY AND BUILDINGS, 2015, 98 :100-105
[28]   Analysis of energy consumption of room air conditioners: An approach using individual operation data from field measurements [J].
Kindaichi, Sayaka ;
Nishina, Daisaku ;
Murakawa, Saburo ;
Ishida, Masaki ;
Ando, Motoki .
APPLIED THERMAL ENGINEERING, 2017, 112 :7-14
[29]   Relating occupant perceived control and thermal comfort: Statistical analysis on the ASHRAE RP-884 database [J].
Langevin, Jared ;
Wen, Jin ;
Gurian, Patrick L. .
HVAC&R RESEARCH, 2012, 18 (1-2) :179-194
[30]   Occupants' behavioural adaptation in workplaces with non-central heating and cooling systems [J].
Liu, Jing ;
Yao, Runming ;
Wang, Juan ;
Li, Baizhan .
APPLIED THERMAL ENGINEERING, 2012, 35 :40-54