Influences of perceived control on thermal comfort and energy use in buildings

被引:89
作者
Yun, Geun Young [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, South Korea
基金
新加坡国家研究基金会;
关键词
Low energy building; Perceived control; Thermal comfort; OCCUPANT BEHAVIOR; ADAPTIVE COMFORT; PERSONAL CONTROL; MODELS; ADAPTATION; OFFICES; SYSTEMS; FIELD; CONSUMPTION; PATTERNS;
D O I
10.1016/j.enbuild.2017.10.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study explores the role of occupants' perceived control in their subjective evaluation of thermal environments and its effects on cooling energy consumption in air-conditioned buildings. Seven air-conditioned buildings with operable windows were selected for field measurements in South Korea. The monitoring data give evidence of a statistically significant relationship between perceived control and the thermal sensations of occupants. The summer comfort temperature for the group with a high level of perceived control over the thermal environment was 0.9 degrees C higher than that for the group with low perceived control. Also, the high perceived control group felt cooler in summer than the low perceived control group. After identifying the effect of perceived control on comfort temperature, dynamic building energy simulations were conducted using EnergyPlus to examine the influence of perceived control on building energy consumption. The simulation results show that increasing occupants' perceived level of control over the thermal environment could reduce cooling energy consumption by 9% without sacrificing the thermal comfort of the occupants. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:822 / 830
页数:9
相关论文
共 62 条
[1]   PMV-PPD and acceptability in naturally ventilated schools [J].
Alfano, Francesca Romana d'Ambrosio ;
Ianniello, Elvira ;
Palella, Boris Igor .
BUILDING AND ENVIRONMENT, 2013, 67 :129-137
[2]  
Alwetaishi M., 2016, Am. J. Eng. Appl. Sci, V9, P928, DOI [10.3844/ajeassp.2016.928.945, DOI 10.3844/AJEASSP.2016.928.945]
[3]  
[Anonymous], 2011, COMMERCIAL REFERENCE
[4]  
[Anonymous], 2011, US DEP ENERGY COMMER
[5]  
[Anonymous], 2013, 552013 ASHRAE
[6]  
[Anonymous], 2005, Ergonomics of the thermal environment -- Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, P2005
[7]  
ASHRAE, 2014, 1402014 ASHRAE
[8]   Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea [J].
Bae, Chihye ;
Chun, Chungyoon .
BUILDING AND ENVIRONMENT, 2009, 44 (11) :2300-2307
[9]   Thermal comfort for free-running buildings [J].
Baker, N ;
Standeven, M .
ENERGY AND BUILDINGS, 1996, 23 (03) :175-182
[10]  
Baker Nick., 2003, Energy and environment in architecture: a technical design guide