Capacitor Voltage Balancing of a Grid-Tied, Cascaded Multilevel Converter with Binary Asymmetric Voltage Levels Using an Optimal One-Step-Ahead Switching-State Combination Approach

被引:4
作者
Kuder, Manuel [1 ]
Kersten, Anton [1 ,2 ]
Marques-Lopez, Jose-Luis [1 ]
Estaller, Julian [1 ]
Buberger, Johannes [1 ]
Schwitzgebel, Florian [1 ]
Thiringer, Torbjoern [2 ]
Lesnicar, Anton [1 ]
Marquardt, Rainer [1 ]
Weyh, Thomas [1 ]
Eckerle, Richard [1 ]
机构
[1] Bundeswehr Univ Munich, Dept Elect Engn, Werner Heisenberg Weg 39, D-85579 Neubiberg, Germany
[2] Chalmers Univ Technol, Dept Elect Engn, Horsalsvagen 11, S-41258 Gothenburg, Sweden
关键词
modular multilevel converters; multilevel systems; power supplies; sensorless control; total harmonic distortion; FAULT-TOLERANT; NEUTRAL POINT; INVERTER; DESIGN; STRATEGY;
D O I
10.3390/en15020575
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a novel capacitor voltage balancing control approach for cascaded multilevel inverters with an arbitrary number of series-connected H-Bridge modules (floating capacitor modules) with asymmetric voltages, tiered by a factor of two (binary asymmetric). Using a nearest-level reference waveform, the balancing approach uses a one-step-ahead approach to find the optimal switching-state combination among all redundant switching-state combinations to balance the capacitor voltages as quickly as possible. Moreover, using a Lyapunov function candidate and considering LaSalle's invariance principle, it is shown that an offline calculated trajectory of optimal switching-state combinations for each discrete output voltage level can be used to operate (asymptotically stable) the inverter without measuring any of the capacitor voltages, achieving a novel sensorless control as well. To verify the stability of the one-step-ahead balancing approach and its sensorless variant, a demonstrator inverter with 33 levels is operated in grid-tied mode. For the chosen 33-level converter, the NPC main-stage and the individual H-bridge modules are operated with an individual switching frequency of about 1 kHz and 2 kHz, respectively. The sensorless approach slightly reduced the dynamic system response and, furthermore, the current THD for the chosen operating point was increased from 3.28 to 4.58 in comparison with that of using the capacitor voltage feedback.
引用
收藏
页数:19
相关论文
共 53 条
[1]  
[Anonymous], P 2016 IEEE 16 INT C, DOI DOI 10.1109/EEEIC.2016.7555871
[2]  
[Anonymous], 2014, IEEE RECOMMENDED PRA, DOI [10.1109/IEEESTD.2014.6826459, DOI 10.1109/IEEESTD.2014.6826459]
[3]  
[Anonymous], 2016, Design, Control, and Application of Modular Multilevel Converter for HVDC Transmission System
[4]  
Babaei Ebrahim, 2007, International Conference on Electrical Machines and Systems 2007, P74
[5]   Investigation of Negative-Sequence Injection Capability of Cascaded H-Bridge Converters in Star and Delta Configuration [J].
Behrouzian, Ehsan ;
Bongiorno, Massimo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) :1675-1683
[6]  
Benzaquen J, 2019, APPL POWER ELECT CO, P588, DOI 10.1109/APEC.2019.8722244
[7]   Improving the Overall Efficiency of Automotive Inverters Using a Multilevel Converter Composed of Low Voltage Si MOSFETs [J].
Chang, Fengqi ;
Ilina, Olga ;
Lienkamp, Markus ;
Voss, Leon .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (04) :3586-3602
[8]   ADAPTIVE-CONTROL OF NONLINEAR-SYSTEMS USING NEURAL NETWORKS [J].
CHEN, FC ;
KHALIL, HK .
INTERNATIONAL JOURNAL OF CONTROL, 1992, 55 (06) :1299-1317
[9]   A new single-phase PLL structure based on second order generalized integrator [J].
Ciobotaru, Mihai ;
Teodorescu, Remus ;
Blaabjerg, Frede .
2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, :361-+
[10]   A new cascaded multilevel H-bridge drive [J].
Corzine, K ;
Familiant, Y .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (01) :125-131