A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode

被引:33
作者
Ayaz, Selen [1 ]
Karakaya, Serkan [1 ]
Emir, Gamze [1 ]
Dilgin, Didem Giray [2 ]
Dilgin, Yusuf [1 ]
机构
[1] Univ Canakkale Onsekiz Mart, Fac Sci & Art, Chem Dept, Canakkale, Turkey
[2] Univ Canakkale Onsekiz Mart, Fac Educ, Secondary Sci & Math Educ Dept, Canakkale, Turkey
关键词
Glucose; Flow injection analysis; Copper nanoparticles; Graphite pencil electrode; Amperometric biosensor; FLOW-INJECTION ANALYSIS; COPPER-OXIDE; ELECTROCHEMICAL SENSOR; GRAPHENE OXIDE; SYSTEM; HYBRID; OXIDATION; NANOWIRE; MEDIATOR;
D O I
10.1016/j.microc.2019.104586
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, graphite pencil electrode (GPE) was modified with Cu nanoparticles (CuNPs) for enzyme-free flow injection (FI) amperometric detection of glucose. To modify electrode, CuNPs were electrodeposited onto GPE surface by recording 10 successive cyclic voltammograms (CVs) of 2.0 mM Cu(NO3)(2) in 100 mM KNO3. The electrochemical characterizations of the electrodes were realized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry techniques. The SEM images and EDX spectra of the pencil leads were recorded to investigate the surface morphologies of the electrodes. Then, the electrochemical response of both unmodified GPE and CuNPs/GPE towards electrochemical oxidation of glucose was performed by recording CVs in the supporting electrolyte consisted of 100 mM NaOH and 100 mM KCl. CVs recorded at GPE showed that the electron transfer rate of glucose is relatively slow and oxidation of glucose irreversibly observed with very low current at a high positive potential (+ 0.70 V). On the other hand, glucose oxidized at more negative potential value ( + 0.45 V) than that of unmodified GPE with a view of sharp peak at CuNPs/GPE. These results show that CuNPs/GPE exhibits excellent electrocatalytic activity and high electrochemical response towards oxidation of glucose because electron transfer rate of glucose was remarkably enhanced by modification of GPE with CuNPs. In the flow injection (FI) amperometric experiments, + 0.45 V and 2.5 mL/min were used as optimal values for applied potential (E-ap) and flow rate (f(r)), respectively. A linear calibration curve was obtained in the range from 0.10 to 400 mu M glucose with a detection limit and sensitivity of 0.04 mu M and 0.830 mu A mu M-1 cm(-2), respectively. The selectivity of glucose sensor was tested in the presence of various interferences. At last step, constructed glucose biosensor was successfully tested on some real glucose samples.
引用
收藏
页数:10
相关论文
共 60 条
[1]   Recent Advances in Nanomaterial-Modified Pencil Graphite Electrodes for Electroanalysis [J].
Akanda, Md. Rajibul ;
Sohail, Manzar ;
Aziz, Md. Abdul ;
Kawde, Abdel-Nasser .
ELECTROANALYSIS, 2016, 28 (03) :408-424
[2]   Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode [J].
Amatatongchai, Maliwan ;
Sroysee, Wongduan ;
Chairam, Sanoe ;
Nacapricha, Duangjai .
TALANTA, 2017, 166 :420-427
[3]   Non-enzymatic glucose sensor based on copper oxide and multi-wall carbon nanotubes using PEDOT:PSS matrix [J].
Amirzadeh, Zhila ;
Javadpour, Sirus ;
Shariat, Mohammad Hossein ;
Knibbe, Ruth .
SYNTHETIC METALS, 2018, 245 :160-166
[4]   Highly efficient nonenzymatic glucose sensors based on CuO nanoparticles [J].
Ashok, Anchu ;
Kumar, Anand ;
Tarlochan, Faris .
APPLIED SURFACE SCIENCE, 2019, 481 :712-722
[5]   Flow injection amperometric determination of hydrazine based on its electrocatalytic oxidation at pyrocatechol violet modified pencil graphite electrode [J].
Ayaz, Selen ;
Dilgin, Yusuf .
ELECTROCHIMICA ACTA, 2017, 258 :1086-1095
[6]   Three-Dimensional Dendrite Cu-Co/Reduced Graphene Oxide Architectures on a Disposable Pencil Graphite Electrode as an Electrochemical Sensor for Nonenzymatic Glucose Detection [J].
Babu, K. Justice ;
Sheet, Sunirmal ;
Lee, Yang Soo ;
Kumar, G. Gnana .
ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (02) :1909-1918
[7]   Minimally Invasive Glucose Monitoring Using a Highly Porous Gold Microneedles-Based Biosensor: Characterization and Application in Artificial Interstitial Fluid [J].
Bollella, Paolo ;
Sharma, Sanjiv ;
Cass, Anthony E. G. ;
Tasca, Federico ;
Antiochia, Riccarda .
CATALYSTS, 2019, 9 (07)
[8]   Facile Synthesis of Ni(OH)2 Modified Disposable Pencil Graphite Electrode and its Application for Highly Sensitive Non-enzymatic Glucose Sensor [J].
Chelaghmia, Mohamed Lyamine ;
Nacef, Mouna ;
Affoune, Abed Mohamed ;
Pontie, Maxime ;
Derabla, Tahar .
ELECTROANALYSIS, 2018, 30 (06) :1117-1124
[9]   Recent advances in electrochemical glucose biosensors: a review [J].
Chen, Chao ;
Xie, Qingji ;
Yang, Dawei ;
Xiao, Hualing ;
Fu, Yingchun ;
Tan, Yueming ;
Yao, Shouzhuo .
RSC ADVANCES, 2013, 3 (14) :4473-4491
[10]  
da Costa Silva L.M., 2013, STATE ART BIOSENSORS, P156