Reproducibility of interictal EEG-fMRI results in patients with epilepsy

被引:29
作者
Gholipour, Taha [1 ]
Moeller, Friederike [1 ]
Pittau, Francesca [1 ]
Dubeau, Francois [1 ]
Gotman, Jean [1 ]
机构
[1] Montreal Neurol Hosp & Inst, Montreal, PQ H3A 2B4, Canada
基金
加拿大健康研究院;
关键词
EEG-fMRI; Reliability; Localization; Blood oxygenation level dependent; Epilepsy surgery; FUNCTIONAL MRI; FOCAL EPILEPSY; BOLD RESPONSES; 1.5; T; NETWORKS; CHILDREN; SURGERY; SPIKES; FEASIBILITY; COMBINATION;
D O I
10.1111/j.1528-1167.2010.02768.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
P>Purpose: Combined electroencephalography (EEG) and functional MRI (EEG-fMRI) can be useful in the evaluation of epilepsy patients. The reproducibility of EEG-fMRI findings needs to be established to consider it as a clinically valuable method. We addressed the intrasubject reproducibility of EEG-fMRI and the possible superiority of higher magnetic field strength in patients who were scanned twice. Methods: Fifteen patients were studied: Seven had one 1.5T and one 3T scan and eight had two 3T EEG-fMRI studies. Equal numbers of events of the same interictal epileptic discharge (IED) were included, and IED-related blood oxygenation level dependent (BOLD) results were compared. Key Findings: In 1.5T-3T comparisons, five patients had BOLD responses in both studies, but in four there was a better response (higher maximum t-score and larger cluster) in 3T studies. One patient had a BOLD response in the 3T study only. The remaining patient had no BOLD response in either study. In 3T-3T comparisons, results were reproducible in five of eight patients, and one patient had no response in both studies. The two remaining patients had previous extensive surgery and extremely frequent IEDs. Some of the reproduced patterns in other patients, however, differed in terms of maximum t-score and cluster size. Significance: EEG-fMRI appears to provide reasonable reproducibility, although repeated studies may show differences. The absence of BOLD response seems to be reproducible as well. EEG-fMRI results tend to benefit from higher field scanners (3T over 1.5T). Further studies are needed to determine if reproducibility depends on specific clinical, electrographic, or anatomic findings.
引用
收藏
页码:433 / 442
页数:10
相关论文
共 38 条
  • [1] fMRI activation during spike and wave discharges in idiopathic generalized epilepsy
    Aghakhani, Y
    Bagshaw, AP
    Bénar, CG
    Hawco, C
    Andermann, F
    Dubeau, F
    Gotman, J
    [J]. BRAIN, 2004, 127 : 1127 - 1144
  • [2] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [3] 3 T MRI: Advances in brain imaging
    Alvarez-Linera, Juan
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (03) : 415 - 426
  • [4] EEG-fMRI of focal epileptic spikes:: Analysis with multiple haemodynamic functions and comparison with gadolinium-enhanced MR angiograms
    Bagshaw, AP
    Aghakhani, Y
    Bénar, CG
    Kobayashi, E
    Hawco, C
    Dubeau, F
    Pike, GB
    Gotman, J
    [J]. HUMAN BRAIN MAPPING, 2004, 22 (03) : 179 - 192
  • [5] Quality of EEG in simultaneous EEG-fMRI for epilepsy
    Bénar, CG
    Aghakhani, Y
    Wang, YH
    Izenberg, A
    Al-Asmi, A
    Dubeau, F
    Gotman, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2003, 114 (03) : 569 - 580
  • [6] Briellmann RS, 2003, EPILEPTIC DISORD, V5, P3
  • [7] Towards clinical standards for EEG/fMRI
    de Munck, Jan C.
    Ossenblok, Pauly P. W.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (09) : 1617 - 1618
  • [8] The current status of neuroimaging for epilepsy
    Duncan, John
    [J]. CURRENT OPINION IN NEUROLOGY, 2009, 22 (02) : 179 - 184
  • [9] How wrong can we be? The effect of inaccurate mark-up of EEG/fMRI studies in epilepsy
    Flanagan, Danny
    Abbott, David F.
    Jackson, Graeme D.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (09) : 1637 - 1647
  • [10] Nonlinear event-related responses in fMRI
    Friston, KJ
    Josephs, O
    Rees, G
    Turner, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 41 - 52