Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography

被引:35
|
作者
Kim, Dae Jung [1 ]
Kim, Tae Hoon [1 ]
Kim, Sang Jin [1 ]
Kim, Dong Phil [1 ]
Oh, Chi Suk [1 ]
Ryu, Young Hoon [1 ]
Kim, Young Jin [1 ]
Choi, Byoung Wook [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Seoul 120749, South Korea
关键词
D O I
10.1148/radiol.2453061953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively investigate the effect of the injection rate of a saline solution as a bolus chaser for the enhancement of the aorta and coronary arteries at multidetector computed tomographic (CT) coronary angiography. Materials and Methods: Institutional review board approved this study, and all patients gave informed consent. One hundred consecutive patients (59 men, 41 women; mean age, 58 years +/- 11 [standard deviation]) underwent 64-section CT coronary angiography for coronary artery disease. They were divided into five groups (each group, n = 20) according to the injection rate of saline solution (3, 4, 5, 6, and 7 mL/sec). Iodinated contrast medium (60 mL) was injected intravenously at a rate of 4 mL/sec, followed by 60 mL saline solution administered intravenously at a rate of 3-7 mL/sec, depending on the groups. Attenuation values of the aortic root, right coronary artery, left anterior descending artery, and left circumflex artery were measured. Analysis of variance with the Scheffe method was used to evaluate statistical significance of the differences in attenuation according to the injection rate of saline solution. Results: The degree of contrast enhancement was affected by the injection rate of saline solution, and the attenuation values were higher as the injection rate increased up to 4-5 mL/sec (P <.05). The values plateaued at rates over 5 mL/sec in the aorta and over 4 mL/sec in the coronary arteries. Conclusion: An injection rate of 4-5 mL/sec as a saline solution chaser is optimal for achieving maximum attenuation values of the aorta or coronary arteries by using 64-section CT with 60 mL contrast material.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 50 条
  • [1] Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography
    Tomizawa, Nobuo
    Suzuki, Fumio
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1255 - 1259
  • [2] CT angiography of the coronary arteries
    Klow, N
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2006, 40 (02) : 69 - 70
  • [3] Multidetector-row CT angiography of the aorta and visceral arteries
    Wintersperger, BJ
    Nikolaou, K
    Becker, CR
    SEMINARS IN ULTRASOUND CT AND MRI, 2004, 25 (01) : 25 - 40
  • [4] Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography
    Kang, Koung Mi
    Choi, Sang Il
    Chun, Eun Ju
    Kim, Jeong A.
    Youn, Tae-Jin
    Choi, Dong Ju
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 27 - 33
  • [5] Noncoronary findings on multidetector CT coronary angiography
    Shafique, I
    Shapiro, EP
    Stafford, S
    Bush, DE
    CIRCULATION, 2004, 110 (17) : 523 - 523
  • [6] Multislice CT coronary angiography: Effect of sublingual nitroglycerine on the diameter of coronary arteries
    Dewey, M.
    Hoffmann, H.
    Hamm, B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (06): : 600 - 604
  • [7] Postmortem enhancement of coronary arteries by multiphase whole body CT angiography. Comparison with antemortem coronary angiography
    Heinemann, A.
    Muellerleile, K.
    Chevalier, C.
    Grabherr, S.
    Vogel, H.
    RECHTSMEDIZIN, 2014, 24 (02) : 107 - 113
  • [8] Are CT and Angiography of the Coronary Arteries equal?
    Doenst, T.
    KARDIOLOGE, 2019, 13 (05): : 250 - 250
  • [9] Coronary CT Angiography in the Detection of Congenital Malignant Coronary Arteries
    Sultani, T.
    Richardson, R.
    Musil, I.
    Nigro, J.
    Diab, K.
    Pophal, S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [10] Multislice coronary CT angiography: Effect of heart rate and BMI on visualization of coronary arteries
    Talmi, D
    White, CS
    Jain, V
    Read, K
    Talmi, A
    Musk, AE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 66 - 67