Improved ion optics for introduction of ions into a 9.4-T Fourier transform ion cyclotron resonance mass spectrometer

被引:11
作者
Chen, Yu [1 ]
Leach, Franklin E., III [2 ]
Kaiser, Nathan K. [1 ]
Dang, Xibei [3 ]
Ibrahim, Yehia M. [2 ]
Norheim, Randolph V. [2 ]
Anderson, Gordon A. [2 ]
Smith, Richard D. [2 ]
Marshall, Alan G. [1 ,3 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ion Cyclotron Resonance Program, Tallahassee, FL 32310 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
[3] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2015年 / 50卷 / 01期
基金
美国国家科学基金会;
关键词
FT MS; ICR; quadrupole ion guide; ion funnel; mass selection; ELECTRON-CAPTURE DISSOCIATION; FUNNEL INTERFACE; RESOLUTION; SENSITIVITY; IMPLEMENTATION; ACCUMULATION; EXCITATION; PROTEIN;
D O I
10.1002/jms.3523
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Enhancements to the ion source and transfer optics of our 9.4T Fourier transform ion cyclotron resonance (ICR) mass spectrometer have resulted in improved ion transmission efficiency for more sensitive mass measurement of complex mixtures at the MS and MS/MS levels. The tube lens/skimmer has been replaced by a dual ion funnel and the following octopole by a quadrupole for reduced ion cloud radial expansion before transmission into a mass-selective quadrupole. The number of ions that reach the ICR cell is increased by an order of magnitude for the funnel/quadrupole relative to the tube lens/skimmer/octopole. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:280 / 284
页数:5
相关论文
共 30 条
[1]  
[Anonymous], ADV CHEM PHYS 1
[2]  
Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
[3]   Predator data station: A fast data acquisition system for advanced FT-ICR MS experiments [J].
Blakney, Greg T. ;
Hendrickson, Christopher L. ;
Marshall, Alan G. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 306 (2-3) :246-252
[4]  
Dawson P. H., 1976, QUADRUPOLE MASS SPEC, P121
[5]  
Dehmelt H.G., 1968, Advances in Atomic and Molecular Physics, V3, P53, DOI [10.1016/S0065-2199(08)60170-0, DOI 10.1016/S0065-2199(08)60170-0]
[6]   Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applications [J].
Guan, SH ;
Marshall, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 157 :5-37
[7]   Baseline mass resolution of peptide isobars: A record for molecular mass resolution [J].
He, F ;
Hendrickson, CL ;
Marshall, AG .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :647-650
[8]   Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface [J].
Ibrahim, Yehia ;
Tang, Keqi ;
Tolmachev, Aleksey V. ;
Shvartsburg, Alexandre A. ;
Smith, Richard D. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (09) :1299-1305
[9]   Development of a new ion mobility (quadrupole) time-of-flight mass spectrometer [J].
Ibrahim, Yehia M. ;
Baker, Erin S. ;
Danielson, William F., III ;
Norheim, Randolph V. ;
Prior, David C. ;
Anderson, Gordon A. ;
Belov, Mikhail E. ;
Smith, Richard D. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 :655-662
[10]   Electrically Compensated Fourier Transform Ion Cyclotron Resonance Cell for Complex Mixture Mass Analysis [J].
Kaiser, Nathan K. ;
Savory, Joshua J. ;
McKenna, Amy M. ;
Quinn, John P. ;
Hendrickson, Christopher L. ;
Marshall, Alan G. .
ANALYTICAL CHEMISTRY, 2011, 83 (17) :6907-6910