Determination of Cr(III) and Cr(VI) at Sub-ppb Levels in Water with Solid-Phase Extraction/Metal Furnace Atomic Absorption Spectrometry

被引:35
作者
Inui, Tetsuo [1 ]
Fujita, Kazuhiro [1 ]
Kitano, Masaru [1 ]
Nakamura, Toshihiro [1 ]
机构
[1] Meiji Univ, Dept Appl Chem, Tama Ku, Kawasaki, Kanagawa 2148571, Japan
关键词
DUAL MINI-COLUMNS; PLASMA-MASS SPECTROMETRY; COMPLEX-FORMATION; ICP-AES; SPECIATION; CHROMIUM(III); SYSTEM; PRECONCENTRATION; ACID; RESIN;
D O I
10.2116/analsci.26.1093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method using solid-phase extraction combined with metal furnace atomic absorption spectrometry was developed for the determination of Cr(III) and Cr(VI) at sub-ppb levels in water. A 500-ml water sample was adjusted to pH 3 with nitric acid and then passed through an iminodiacetate extraction disk placed on a cation-exchange extraction disk at a flow rate of 20 - 40 ml min(-1) for concentrating Cr(III) The filtrate was adjusted to pH 10 with aqueous ammonia and then passed through an anion-exchange extraction disk at a flow rate of 2 ml min(-1) for concentrating Cr(VI) The Cr(III) and Cr(VI) collected were eluted with 40 ml of 3 mol nitric acid for Cr(III) and 40 ml of 1 g diphenylcarbazide solution for Cr(VI). Each eluate was diluted to 50 ml with deionized water and injected into a U-type tungsten board on the metal furnace The calibration curves of Cr(III) and Cr(VI) showed good linearity in the range of 0.1 - 0.5 ng The detection limits corresponding to three times the standard deviation (n = 5) of blank values were 8 1 pg for both Cr(III) and Cr(VI) The analytical value of total Cr (Cr(III) + Cr(VI)) in certified reference material of river water (JSAC 0302-3) was in good agreement with the reference value The recovery test for 0 50 kg (1.00 mu g l(-1)) of Cr(III) and Cr(VI) added to 500 ml of the water samples showed sufficient values (98.1 - 106%). except for river water sampled downstream due to relatively higher COD(Mn) value. The relative standard deviations (n = 5) were less than 5% for both Cr(III) and Cr(VI).
引用
收藏
页码:1093 / 1098
页数:6
相关论文
共 35 条
[1]  
[Anonymous], 2006, STANDARD REFERENCE M
[2]   REDUCTION OF LOW CONCENTRATION CR(VI) IN ACID-SOLUTIONS [J].
ARCHUNDIA, C ;
BONATO, PS ;
RIVERA, JFL ;
MASCIOLI, LC ;
COLLINS, KE ;
COLLINS, CH .
SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 130 :231-236
[3]   REDUCTION OF CHROMIUM(VI) AT SUB-MUG 1-1 LEVELS BY FULVIC-ACID [J].
ECKERT, JM ;
STEWART, JJ ;
WAITE, TD ;
SZYMCZAK, R ;
WILLIAMS, KL .
ANALYTICA CHIMICA ACTA, 1990, 236 (02) :357-362
[4]  
EZAKI T, 1991, BUNSEKI KAGAKU, V40, P157
[5]  
FUDAGAWA N, 1982, BUNSEKI KAGAKU, V31, P324
[6]   Chromium(III) binding abilities of humic acids [J].
Fukushima, M ;
Nakayasu, K ;
Tanaka, S ;
Nakamura, H .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :195-206
[7]   Automated Pretreatment System for the Speciation of Cr(III) and Cr(VI) Using Dual Mini-Columns Packed with Newly Synthesized Chitosan Resin and ME-03 Resin [J].
Furusho, Yosbiaki ;
Sabarudin, Akbmad ;
Hakim, Lukman ;
Oshita, Koji ;
Oshima, Mitsuko ;
Motomizu, Shoji .
ANALYTICAL SCIENCES, 2009, 25 (01) :51-56
[8]  
Hanya T., 1960, SUISITUTYOUSAHOU WAT, P54
[9]   A dual column system using agarose-based adsorbents for preconcentration and speciation of chromium in water [J].
Hashemi, P ;
Boroumand, J ;
Fat'hi, MR .
TALANTA, 2004, 64 (03) :578-583
[10]   Determination of chromium(III) and total chromium in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Honda, K ;
Shikino, O ;
Maekawa, N ;
Aihara, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1089-1099