Determination of Cr(III) and Cr(VI) at Sub-ppb Levels in Water with Solid-Phase Extraction/Metal Furnace Atomic Absorption Spectrometry

被引:35
作者
Inui, Tetsuo [1 ]
Fujita, Kazuhiro [1 ]
Kitano, Masaru [1 ]
Nakamura, Toshihiro [1 ]
机构
[1] Meiji Univ, Dept Appl Chem, Tama Ku, Kawasaki, Kanagawa 2148571, Japan
关键词
DUAL MINI-COLUMNS; PLASMA-MASS SPECTROMETRY; COMPLEX-FORMATION; ICP-AES; SPECIATION; CHROMIUM(III); SYSTEM; PRECONCENTRATION; ACID; RESIN;
D O I
10.2116/analsci.26.1093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method using solid-phase extraction combined with metal furnace atomic absorption spectrometry was developed for the determination of Cr(III) and Cr(VI) at sub-ppb levels in water. A 500-ml water sample was adjusted to pH 3 with nitric acid and then passed through an iminodiacetate extraction disk placed on a cation-exchange extraction disk at a flow rate of 20 - 40 ml min(-1) for concentrating Cr(III) The filtrate was adjusted to pH 10 with aqueous ammonia and then passed through an anion-exchange extraction disk at a flow rate of 2 ml min(-1) for concentrating Cr(VI) The Cr(III) and Cr(VI) collected were eluted with 40 ml of 3 mol nitric acid for Cr(III) and 40 ml of 1 g diphenylcarbazide solution for Cr(VI). Each eluate was diluted to 50 ml with deionized water and injected into a U-type tungsten board on the metal furnace The calibration curves of Cr(III) and Cr(VI) showed good linearity in the range of 0.1 - 0.5 ng The detection limits corresponding to three times the standard deviation (n = 5) of blank values were 8 1 pg for both Cr(III) and Cr(VI) The analytical value of total Cr (Cr(III) + Cr(VI)) in certified reference material of river water (JSAC 0302-3) was in good agreement with the reference value The recovery test for 0 50 kg (1.00 mu g l(-1)) of Cr(III) and Cr(VI) added to 500 ml of the water samples showed sufficient values (98.1 - 106%). except for river water sampled downstream due to relatively higher COD(Mn) value. The relative standard deviations (n = 5) were less than 5% for both Cr(III) and Cr(VI).
引用
收藏
页码:1093 / 1098
页数:6
相关论文
共 35 条
  • [1] [Anonymous], 2006, STANDARD REFERENCE M
  • [2] REDUCTION OF LOW CONCENTRATION CR(VI) IN ACID-SOLUTIONS
    ARCHUNDIA, C
    BONATO, PS
    RIVERA, JFL
    MASCIOLI, LC
    COLLINS, KE
    COLLINS, CH
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 130 : 231 - 236
  • [3] REDUCTION OF CHROMIUM(VI) AT SUB-MUG 1-1 LEVELS BY FULVIC-ACID
    ECKERT, JM
    STEWART, JJ
    WAITE, TD
    SZYMCZAK, R
    WILLIAMS, KL
    [J]. ANALYTICA CHIMICA ACTA, 1990, 236 (02) : 357 - 362
  • [4] EZAKI T, 1991, BUNSEKI KAGAKU, V40, P157
  • [5] FUDAGAWA N, 1982, BUNSEKI KAGAKU, V31, P324
  • [6] Chromium(III) binding abilities of humic acids
    Fukushima, M
    Nakayasu, K
    Tanaka, S
    Nakamura, H
    [J]. ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 195 - 206
  • [7] Automated Pretreatment System for the Speciation of Cr(III) and Cr(VI) Using Dual Mini-Columns Packed with Newly Synthesized Chitosan Resin and ME-03 Resin
    Furusho, Yosbiaki
    Sabarudin, Akbmad
    Hakim, Lukman
    Oshita, Koji
    Oshima, Mitsuko
    Motomizu, Shoji
    [J]. ANALYTICAL SCIENCES, 2009, 25 (01) : 51 - 56
  • [8] Hanya T., 1960, SUISITUTYOUSAHOU WAT, P54
  • [9] A dual column system using agarose-based adsorbents for preconcentration and speciation of chromium in water
    Hashemi, P
    Boroumand, J
    Fat'hi, MR
    [J]. TALANTA, 2004, 64 (03) : 578 - 583
  • [10] Determination of chromium(III) and total chromium in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry
    Hirata, S
    Honda, K
    Shikino, O
    Maekawa, N
    Aihara, M
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) : 1089 - 1099