Infrarenal aortic stenosis:: Long-term clinical and hemodynamic results of percutaneous transluminal angioplasty
被引:35
|作者:
Audet, P
Therasse, E
Oliva, VL
Soulez, G
Côté, G
Wistaff, R
Nguyen, PV
Blair, JF
Bui, BT
Cusson, JR
机构:
[1] Univ Montreal, Med Ctr, Dept Radiol, Montreal, PQ H2W 1T8, Canada
[2] Univ Montreal, Med Ctr, Div Internal Med, Montreal, PQ H2W 1T8, Canada
[3] Univ Montreal, Med Ctr, Div Vasc Surg, Montreal, PQ H2W 1T8, Canada
[4] Hop St Sacrement, Dept Radiol, Quebec City, PQ, Canada
来源:
关键词:
aorta;
stenosis or obstruction;
transluminal angioplasty;
interventional procedures;
D O I:
10.1148/radiology.209.2.9807559
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
PURPOSE: To evaluate the safety and long-term clinical and hemodynamic results of percutaneous transluminal angioplasty (PTA) of the infrarenal aorta. MATERIALS AND METHODS: During nearly 10 years, 102 patients with symptomatic infrarenal atherosclerotic aortic stenosis underwent PTA. Follow-up information was available in 92 patients (17 men, 75 women; mean age, 51.9 years). Stenosis involved the aortic bifurcation in 18 patients and only the infrarenal abdominal aorta in 74 patients. Technical success was defined as residual stenosis less than 50% or a pressure gradient less than 10 mm Hg after PTA. Clinical patency was defined as the absence or improvement of symptoms after PTA. Hemodynamic patency was defined asa normal Doppler waveform in the common femoral arteries,an ankle-brachial ratio greater than 0.95, or the absence of a thigh-brachial pressure gradient. RESULTS: Technical success was achieved in 78 patients after PTA. After 10 years, primary clinical and hemodynamic patency rates were 72% and 46%, respectively. After a mean follow-up of 51 months, 15 of the 22 symptomatic recurrences were due to aortic restenosis; 11 of these were treated with repeated PTA with or without stent placement, and three eventually required aortic surgery. No morbidity was encountered. CONCLUSION: Infrarenal aortic PTA proved to be safe and provided durable, long-term clinical improvement. In this group of relatively young patients, the clinical patency rate of PTA was equivalent to that of aortic surgery but with less morbidity.
引用
收藏
页码:357 / 363
页数:7