Correction of sensor crosstalk error in Exhalyzer D multiple-breath washout device significantly impacts outcomes in children with cystic fibrosis

被引:73
作者
Wyler, Florian [1 ]
Oestreich, Marc-Alexander [1 ,2 ]
Frauchiger, Bettina S. [1 ,3 ]
Ramsey, Kathryn A. [1 ]
Latzin, Philipp [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Paediat, Div Paediat Resp Med & Allergol,Inselspital, Bern, Switzerland
[2] Univ Bern, Grad Sch Hlth Sci, Bern, Switzerland
[3] Univ Bern, Grad Sch Cellular & Biomed Sci, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
cystic fibrosis; lung clearance index; pulmonary function testing; ventilation inhomogeneity; LUNG CLEARANCE INDEX; INERT-GAS WASHOUT; YOUNG-CHILDREN; DISEASE; F508DEL-CFTR; FEASIBILITY; PROGRESSION; IVACAFTOR; EFFICACY; PHASE-3;
D O I
10.1152/japplphysiol.00338.2021
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Nitrogen multiple-breath washout is an established technique to assess functional residual capacity and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes. We investigated the accuracy of oxygen and carbon dioxide gas sensor measurements used for the indirect calculation of nitrogen concentration in a commercial multiple-breath washout device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on functional residual capacity and lung clearance index. High-precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on multiple-breath washout outcomes in a data set of healthy children and children with cystic fibrosis using custom analysis software. We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration and consequently, multiple-breath washout outcomes. Breath-by-breath correction of this error reduced the mean (SD) cumulative expired volume by 19.6% (5.0%), functional residual capacity by 8.9% (2.2%), and lung clearance index by 11.9% (4.0%). It also substantially reduced the level of the tissue nitrogen signal at the end of measurements. Inadequate correction for cross sensitivity in the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of functional residual capacity and lung clearance index. Correction of this error is possible and could be applied by reanalyzing the measurements in an updated software version. NEW & NOTEWORTHY We investigated the sensor accuracy of a prominent nitrogen multiple-breath washout (N2MBW) device (Eco Medics AG, Duernten, Switzerland) as a possible cause of lack of comparability between outcomes of different MBW devices and methods. We identified an error in the nitrogen concentration calculation of this device, which results in a 10%-15% overestimation of primary outcomes, functional residual capacity, and lung clearance index. It also leads to a significant overestimation of nitrogen back-diffusion into the lungs.
引用
收藏
页码:1148 / 1156
页数:9
相关论文
共 35 条
[1]   Normative data for multiple breath washout outcomes in school-aged Caucasian children [J].
Anagnostopoulou, Pinelopi ;
Latzin, Philipp ;
Jensen, Renee ;
Stahl, Mirjam ;
Harper, Alana ;
Yammine, Sophie ;
Usemann, Jakob ;
Foong, Rachel E. ;
Spycher, Ben ;
Hall, Graham L. ;
Singer, Florian ;
Stanojevic, Sanja ;
Mall, Marcus A. ;
Ratjen, Felix ;
Ramsey, Kathryn A. .
EUROPEAN RESPIRATORY JOURNAL, 2020, 55 (04)
[2]   Infrared CO2 analyzer error:: an effect of background gas (N2 and O2) [J].
Arieli, R ;
Ertracht, O ;
Daskalovic, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) :647-650
[3]   Simultaneous sulfur hexafluoride and nitrogen multiple-breath washout (MBW) to examine inherent differences in MBW outcomes [J].
Bayfield, Katie J. ;
Horsley, Alex ;
Alton, Eric ;
Irving, Samantha ;
Bush, Andrew ;
Davies, Jane C. .
ERJ OPEN RESEARCH, 2019, 5 (04)
[4]   Feasibility and challenges of using multiple breath washout in COPD [J].
Bell, Alan S. ;
Lawrence, Philip J. ;
Singh, Dave ;
Horsley, Alexander .
INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 :2113-2119
[5]   Laser-based absorption spectroscopy as a technique for rapid in-line analysis of respired gas concentrations of O2 and CO2 [J].
Cummings, Beth ;
Hamilton, Michelle L. ;
Ciaffoni, Luca ;
Pragnell, Timothy R. ;
Peverall, Rob ;
Ritchie, Grant A. D. ;
Hancock, Gus ;
Robbins, Peter A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (01) :303-307
[6]   A phase 3, double-blind, parallel-group study to evaluate the efficacy and safety of tezacaftor in combination with ivacaftor in participants 6 through 11 years of age with cystic fibrosis homozygous for F508del or heterozygous for the F508del-CFTR mutation and a residual function mutation [J].
Davies, Jane C. ;
Sermet-Gaudelus, Isabelle ;
Naehrlich, Lutz ;
Harris, R. Scott ;
Campbell, Daniel ;
Ahluwalia, Neil ;
Short, Christopher ;
Haseltine, Eric ;
Panorchan, Paul ;
Saunders, Clare ;
Owen, Caroline A. ;
Wainwright, Claire E. .
JOURNAL OF CYSTIC FIBROSIS, 2021, 20 (01) :68-77
[7]   The clinical utility of lung clearance index in early cystic fibrosis lung disease is not impacted by the number of multiple-breath washout trials [J].
Foong, Rachel E. ;
Harper, Alana J. ;
Skoric, Billy ;
King, Louise ;
Turkovic, Lidija ;
Davis, Miriam ;
Clem, Charles C. ;
Rosenow, Tim ;
Davis, Stephanie D. ;
Ranganathan, Sarath ;
Hall, Graham L. ;
Ramsey, Kathryn A. .
ERJ OPEN RESEARCH, 2018, 4 (01)
[8]   Longitudinal course of clinical lung clearance index in children with cystic fibrosis [J].
Frauchiger, Bettina S. ;
Binggeli, Severin ;
Yammine, Sophie ;
Spycher, Ben ;
Kruger, Linn ;
Ramsey, Kathryn A. ;
Latzin, Philipp .
EUROPEAN RESPIRATORY JOURNAL, 2021, 58 (01)
[9]   Multiple breath washout quality control in the clinical setting [J].
Frauchiger, Bettina S. ;
Carlens, Julia ;
Herger, Andreas ;
Moeller, Alexander ;
Latzin, Philipp ;
Ramsey, Kathryn A. .
PEDIATRIC PULMONOLOGY, 2021, 56 (01) :105-112
[10]   Difference between SF6 and N2 multiple breath washout kinetics is due to N2 back diffusion and error in N2 offset [J].
Guglani, Lokesh ;
Kasi, Ajay ;
Starks, Miah ;
Pedersen, Knud E. ;
Nielsen, Jorgen G. ;
Weiner, Daniel J. .
JOURNAL OF APPLIED PHYSIOLOGY, 2018, 125 (04) :1257-1265