Surface plasmon resonance biosensing: Approaches for screening and characterising antibodies for food diagnostics

被引:35
作者
Yakes, B. J. [1 ]
Buijs, J. [2 ,4 ]
Elliott, C. T. [3 ]
Campbell, K. [3 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, 5100 Paint Branch Pkwy, College Pk, MD 20740 USA
[2] GE Healthcare Biosci AB, Bjorkgatan 30, S-75184 Uppsala, Sweden
[3] Queens Univ Belfast, Sch Biol Sci, Inst Global Food Secur, David Keir Bldg,Stranmillis Rd, Belfast BT9 5AG, Antrim, North Ireland
[4] Uppsala Univ, Dept Radiol Oncol & Radiat Sci, Uppsala, Sweden
关键词
Surface plasmon resonance; Antibody; Biosensor; Domoic acid; Marine toxin; Shellfish; DOMOIC ACID; MONOCLONAL-ANTIBODY; OKADAIC ACID; SHELLFISH; CONTAMINATION; SEAFOOD; TOXINS; ASSAY; IMMUNOSENSOR; IMMUNOASSAY;
D O I
10.1016/j.talanta.2016.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Research in biosensing approaches as alternative techniques for food diagnostics for the detection of chemical contaminants and foodborne pathogens has increased over the last twenty years. The key component of such tests is the biorecognition element whereby polyclonal or monoclonal antibodies still dominate the market. Traditionally the screening of sera or cell culture media for the selection of polyclonal or monoclonal candidate antibodies respectively has been performed by enzyme immunoassays. For niche toxin compounds, enzyme immunoassays can be expensive and/or prohibitive methodologies for antibody production due to limitations in toxin supply for conjugate production. Automated, self-regenerating, chip-based biosensors proven in food diagnostics may be utilised as rapid screening tools for antibody candidate selection. This work describes the use of both single channel and multi-channel surface plasmon resonance (SPR) biosensors for the selection and characterisation of antibodies, and their evaluation in shellfish tissue as standard techniques for the detection of domoic acid, as a model toxin compound. The key advantages in the use of these biosensor techniques for screening hybridomas in monoclonal antibody production were the real time observation of molecular interaction and rapid turnaround time in analysis compared to enzyme immunoassays. The multichannel prototype instrument was superior with 96 analyses completed in 2 h compared to 12 h for the single channel and over 24 h for the ELISA immunoassay. Antibodies of high sensitivity, IC50's ranging from 4.8 to 6.9 ng/mL for monoclonal and 2.3-6.0 ng/mL for polyclonal, for the detection of domoic acid in a 1 min analysis time were selected. Although there is a progression for biosensor technology towards low cost, multiplexed portable diagnostics for the food industry, there remains a place for laboratory-based SPR instrumentation for antibody development for food diagnostics as shown herein. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 63
页数:9
相关论文
共 41 条
[1]   Sudan I induces genotoxic effects and oxidative DNA damage in HepG2 cells [J].
An, Yu ;
Jiang, Liping ;
Cao, Jun ;
Geng, Chengyan ;
Zhong, Laifu .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2007, 627 (02) :164-170
[2]  
[Anonymous], 2015, CHEM ENG NEWS, V93, P8
[3]  
AOAC International, 2007, 200602 AOAC INT
[4]   Biosensors to detect marine toxins:: Assessing seafood safety [J].
Campas, Monica ;
Prieto-Simon, Beatriz ;
Marty, Jean-Louis .
TALANTA, 2007, 72 (03) :884-895
[5]   Assessment of specific binding proteins suitable for the detection of paralytic shellfish poisons using optical biosensor technology [J].
Campbell, Katrina ;
Stewart, Linda D. ;
Doucette, Gregory J. ;
Fodey, Terence L. ;
Haughey, Simon A. ;
Vilarino, Natalia ;
Kawatsu, Kentaro ;
Elliott, Christopher T. .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5906-5914
[6]   Evolving to the optoelectronic mouse for phycotoxin analysis in shellfish [J].
Campbell, Katrina ;
McNamee, Sara E. ;
Huet, Anne-Catherine ;
Delahaut, Philippe ;
Vilarino, Natalia ;
Botana, Luis M. ;
Poli, Mark ;
Elliott, Christopher T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (27) :6867-6881
[7]   Development and single laboratory validation of an optical biosensor assay for tetrodotoxin detection as a tool to combat emerging risks in European seafood [J].
Campbell, Katrina ;
Barnes, Paul ;
Haughey, Simon A. ;
Higgins, Cowan ;
Kawatsu, Kentaro ;
Vasconcelos, Vitor ;
Elliott, Christopher T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (24) :7753-7763
[8]   Use of a novel micro-fluidic device to create arrays for multiplex analysis of large and small molecular weight compounds by surface plasmon resonance [J].
Campbell, Katrina ;
McGrath, Terry ;
Sjolander, Stefan ;
Hanson, Thord ;
Tidare, Mattias ;
Jansson, Osten ;
Moberg, Anna ;
Mooney, Mark ;
Elliott, Christopher ;
Buijs, Jos .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) :3029-3036
[9]  
Chen JS, 2009, CHIN MED J, V122, P243
[10]  
CHU FS, 1992, J AOAC INT, V75, P341