A 64-Channel Readout ASIC for Nanowire Biosensor Array with Electrical Calibration Scheme

被引:3
作者
Chai, Kevin T. C. [1 ]
Choe, Kunil [1 ]
Bernal, Olivier D. [1 ]
Gopalakrishnan, Pradeep K. [1 ]
Zhang, Guo-Jun [2 ]
Kang, Tae Goo [2 ]
Je, Minkyu [1 ]
机构
[1] ASTAR, Integrated Circuits & Syst Lab, Inst Microelect, Singapore, Singapore
[2] ASTAR, Inst Microelect, Bioelect Programme, Singapore, Singapore
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
SILICON NANOWIRE;
D O I
10.1109/IEMBS.2010.5627783
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A 1.8-mW, 18.5-mm(2) 64-channel current readout ASIC was implemented in 0.18-mu m CMOS together with a new calibration scheme for silicon nanowire biosensor arrays. The ASIC consists of 64 channels of dedicated readout and conditioning circuits which incorporate correlated double sampling scheme to reduce the effect of 1/f noise and offset from the analog front-end. The ASIC provides a 10-bit digital output with a sampling rate of 300 S/s whilst achieving a minimum resolution of 7 pA(rms). A new electrical calibration method was introduced to mitigate the issue of large variations in the nano-scale sensor device parameters and optimize the sensor sensitivity. The experimental results show that the proposed calibration technique improved the sensitivity by 2 to 10 times and reduced the variation between dataset by 9 times.
引用
收藏
页码:3491 / 3494
页数:4
相关论文
共 9 条
  • [1] Calibration method for a carbon nanotube field-effect transistor biosensor
    Abe, Masuhiro
    Murata, Katsuyuki
    Ataka, Tatsuaki
    Matsumoto, Kazuhiko
    [J]. NANOTECHNOLOGY, 2008, 19 (04)
  • [2] Augustyniak M., 2006, IEEE INT SOLID STATE, P46, DOI [10.1109/ISSCC.2006.1696034, DOI 10.1109/ISSCC.2006.1696034]
  • [3] Byungchul Jang, 2009, 2009 IEEE International Solid-State Circuits Conference (ISSCC 2009), P436, DOI 10.1109/ISSCC.2009.4977495
  • [4] Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays
    Chua, Jay Huiyi
    Chee, Ru-Ern
    Agarwal, Ajay
    Wong, She Mein
    Zhang, Guo-Jun
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (15) : 6266 - 6271
  • [5] Gemma N., 2006, IEEE INT SOLID STATE, P560
  • [6] Heer Flavio, 2008, 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers, P168, DOI 10.1109/ISSCC.2008.4523110
  • [7] Model for the field effect from layers of biological macromolecules on the gates of metal-oxide-semiconductor transistors
    Landheer, D
    Aers, G
    McKinnon, WR
    Deen, MJ
    Ranuarez, JC
    [J]. JOURNAL OF APPLIED PHYSICS, 2005, 98 (04)
  • [8] Analytic modelling of biotransistors
    Shinwari, M. W.
    Deen, M. J.
    Selvaganapathy, P.
    [J]. IET CIRCUITS DEVICES & SYSTEMS, 2008, 2 (01) : 158 - 165
  • [9] DNA sensing by silicon nanowire: Charge layer distance dependence
    Zhang, Guo-Jun
    Zhang, Gang
    Chua, Jay Huiyi
    Chee, Ru-Ern
    Wong, Ee Hua
    Agarwal, Ajay
    Buddharaju, Kavitha D.
    Singh, Navab
    Gao, Zhiqiang
    Balasubramanian, N.
    [J]. NANO LETTERS, 2008, 8 (04) : 1066 - 1070