Intracranial time-of-flight MR angiography at 7T with comparison to 3T

被引:90
|
作者
von Morze, Cornelius
Xu, Duan
Purcell, Derk D.
Hess, Christopher P.
Mukherjee, Pratik
Saloner, David
Kelley, Douglas A. C.
Vigneron, Daniel B.
机构
[1] UCSF, Dept Radiol, San Francisco, CA 94158 USA
[2] UCSF UCB Joint Grad Grp Bioengn, San Francisco, CA USA
[3] GE Healthcare Technol, San Francisco, CA USA
关键词
MRA; angiography; 7T; 3T; intracranial; time-of-flight;
D O I
10.1002/jmri.21097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish the feasibility of intracranial time-of-flight (TOF) MR angiography (MRA) at 7T using phased array coils and to compare its performance to 3T. Materials and Methods: In an initial study, five normal volunteers were scanned at 7T and 3T using eight-channel coils and standard acquisition parameters from a clinical TOF protocol. In a second study three additional studies were performed at 7T and 3T using empirically optimized 7T parameters. Contrast-to-noise (CNR) values were measured for major vessel segments. Results: All measurements documented CNR increases at 7T, with a mean increase of 83% in the initial study and 88% in the second study. The CNR values achieved using the latter protocol were similar to the values obtained in the initial study, despite the 42% reduction expected due to the higher spatial resolution. CNR in the smaller peripheral vessels was increased dramatically, resulting in excellent visualization at high resolution. Conclusion: TOF MRA at 7T demonstrated improved visualization of the intracranial vasculature, particularly the smaller peripheral vessels, and may benefit studies of small aneurysms, atherosclerosis, vasospasm, and vasculitis.
引用
收藏
页码:900 / 904
页数:5
相关论文
共 50 条
  • [1] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [2] 7T versus 3T MR Angiography to Assess Unruptured Intracranial Aneurysms
    Leemans, Eva
    Cornelissen, Bart
    Sing, M. L. C.
    Sprengers, Marieke
    van den Berg, Rene
    Roos, Yvo
    Vandertop, W. Pieter
    Slump, Cornelius
    Marquering, Henk
    Majoie, Charles
    JOURNAL OF NEUROIMAGING, 2020, 30 (06) : 779 - 785
  • [3] Evaluation of Intracranial Aneurysms with 7T versus 1.5T Time-of-Flight MR Angiography - Initial Experience
    Moenninghoff, C.
    Maderwald, S.
    Theysohn, J. M.
    Kraff, O.
    Ladd, S. C.
    Ladd, M. E.
    Forsting, M.
    Quick, H. H.
    Wanke, I.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (01): : 16 - 23
  • [4] Assessment of extracranial-intracranial bypass in Moyamoya disease using 3T time-of-flight MR angiography: Comparison with CT angiography
    Chen, Qian
    Qi, Rongfeng
    Cheng, Xiaoqing
    Zhou, Changsheng
    Luo, Song
    Ni, Ling
    Huang, Wei
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2014, 43 (04) : 278 - 283
  • [5] Evaluation of Intracranial Dural Arteriovenous Fistulas: Comparison of Unenhanced 3T 3D Time-of-flight MR Angiography with Digital Subtraction Angiography
    Azuma, Minako
    Hirai, Toshinori
    Shigematsu, Yoshinori
    Kitajima, Mika
    Kai, Yutaka
    Yano, Shigetoshi
    Nakamura, Hideo
    Makino, Keishi
    Iryo, Yasuhiko
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (04) : 285 - 293
  • [6] MR Angiography of the Cerebral Perforating Arteries With Magnetization Prepared Anatomical Reference at 7T: Comparison With Time-of-Flight
    Zwanenburg, Jaco J. M.
    Hendrikse, Jeroen
    Takahara, Taro
    Visser, Fredy
    Luijten, Peter R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1519 - 1526
  • [7] Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
    Platzek, Ivan
    Sieron, Dominik
    Wiggermann, Philipp
    Laniado, Michael
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [8] INTRACRANIAL MR ANGIOGRAPHY - A DIRECT COMPARISON OF 3 TIME-OF-FLIGHT TECHNIQUES
    LEWIN, JS
    LAUB, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (02) : 381 - 387
  • [9] INTRACRANIAL MR ANGIOGRAPHY - A DIRECT COMPARISON OF 3 TIME-OF-FLIGHT TECHNIQUES
    LEWIN, JS
    LAUB, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1133 - 1139
  • [10] 7T MR of intracranial pathology: Preliminary observations and comparisons to 3T and 1.5T
    Obusez, Emmanuel C.
    Lowe, Mark
    Oh, Se-Hong
    Wang, Irene
    Bullen, Jennifer
    Ruggieri, Paul
    Hill, Virginia
    Lockwood, Daniel
    Emch, Todd
    Moon, Doksu
    Loy, Gareth
    Lee, Jonathan
    Kiczek, Matthew
    Massand, Manoj
    Statsevych, Volodymyr
    Stultz, Todd
    Jones, Stephen E.
    NEUROIMAGE, 2018, 168 : 459 - 476