Deep brain stimulation in intraoperative MRI environment - Comparison of imaging techniques and electrode fixation methods

被引:36
作者
Lee, MWY
De Salles, AAF
Frighetto, L
Torres, R
Behnke, E
Bronstein, JM
机构
[1] Univ Calif Los Angeles, Sch Med, Div Neurosurg, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Neurol, Los Angeles, CA 90024 USA
关键词
deep brain stimulation; electrode fixation device; intraoperative magnetic resonance imaging; stereotactic targeting;
D O I
10.1055/s-2004-830169
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We performed 118 consecutive DBS cases from November 1999 to June 2002. Intraoperatively there were 10 cases studied with fluoroscopy, 73 with 0.2 Tesla (T) MRI and 35 with 1.5 T MRI. Ten electrodes were secured by Medtronic caps, 25 by methyl methacrylate with titanium miniplates, and 82 by Navigus caps. The 3-dimensional displacement between the planned target and actual electrode position (3DD) was determined by fusing the postoperative MRI with the preoperative imaging. The 3DD for using Medtronic caps, methyl methacrylate with miniplates, and Navigus caps were 4.80 +/- 3.16,2.64 +/- 1.26 and 2.23 +/- 1.15 mm (mean +/- SD), respectively. Navigus caps had statistically significant accuracy (P = 0.03) in holding the electrode when compared with Medtronic caps, and it facilitated electrode revision. The Fixation devices significantly affect the final vertical position of the electrode. The 3DD for fluoroscopy, 0.2 T and 1.5 T MRI cases were 4.80 +/- 3.16, 2.31 +/- 1.21 and 2.34 +/- 1.14 mm (mean SD), respectively. No statistically significant difference (P = 0.91) in 3DD was demonstrated between 0.2 T and 1.5 T MRI cases. The presence of intraoperative 1.5 T MRI allowed near real-time electrode position confirmation and early detection of hemorrhagic complications. Satisfactory microelectrode recording was feasible in low-field 0.2 T and high-field 1.5 T MRI environments. Further studies on performing DBS in real-time intraoperative MRI are warranted.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 25 条
  • [1] Methylmethacrylate insufficiently fixes deep brain stimulator lead position
    Alterman, RL
    Shils, J
    Rogers, J
    [J]. NEUROSURGERY, 2001, 48 (02) : 458 - 458
  • [2] Neurophysiological effects of stimulation through electrodes in the human subthalamic nucleus
    Ashby, P
    Kim, YJ
    Kumar, R
    Lang, AE
    Lozano, AM
    [J]. BRAIN, 1999, 122 : 1919 - 1931
  • [3] Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus and of other nuclei as a treatment for Parkinson's disease
    Benabid, AL
    Benazzouz, A
    Gao, DM
    Hoffmann, D
    Limousin, P
    Koudsie, A
    Krack, P
    Pollak, P
    [J]. TECHNIQUES IN NEUROSURGERY, 1999, 5 (01): : 5 - 30
  • [4] Functional neurosurgery in the MRI environment
    De Salles, AAF
    Frighetto, L
    Behnke, E
    Sinha, S
    Tseng, L
    Torres, R
    Lee, M
    Cabatan-Awang, C
    Frysinger, R
    [J]. MINIMALLY INVASIVE NEUROSURGERY, 2004, 47 (05) : 284 - 289
  • [5] Role of stereotaxis in the treatment of cerebral palsy
    DeSalles, AAF
    [J]. JOURNAL OF CHILD NEUROLOGY, 1996, 11 : S43 - S50
  • [6] Relevance of image fusion for target point determination in functional neurosurgery
    Duffner, F
    Schiffbauer, H
    Breit, S
    Friese, S
    Freudenstein, D
    [J]. ACTA NEUROCHIRURGICA, 2002, 144 (05) : 445 - 451
  • [7] Eskandar, 1999, Stereotact Funct Neurosurg, V72, P245, DOI 10.1159/000029733
  • [8] Anchoring of deep brain stimulation electrodes using a microplate
    Favre, J
    Taha, JM
    Steel, T
    Burchiel, KJ
    [J]. JOURNAL OF NEUROSURGERY, 1996, 85 (06) : 1181 - 1183
  • [9] Guridi J, 2000, NEUROLOGY, V55, pS21
  • [10] Hariz MI, 1997, ADV STER F, V12, P42