3D-printed heart model to guide LAA closure: useful in clinical practice?

被引:29
作者
Hachulla, Anne-Lise [1 ]
Noble, Stephane [2 ]
Guglielmi, Gabriel [1 ]
Agulleiro, Daniel [3 ]
Mueller, Hajo [2 ]
Vallee, Jean-Paul [1 ]
机构
[1] Univ Hosp Geneva, Div Radiol, Rue Gabrielle Perret Gentil 4, CH-1291 Geneva, Switzerland
[2] Univ Hosp Geneva, Dept Cardiol, Geneva, Switzerland
[3] Fac Sci, Ctr Comp Sci, Carouge, Switzerland
关键词
Atrial appendage; Atrial fibrillation; 3D printing; Personalized 3D-printed models; New emerging technology; LEFT ATRIAL APPENDAGE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; 3D PRINT; FIBRILLATION; OCCLUSION; STROKE; DEVICE; SYSTEM;
D O I
10.1007/s00330-018-5569-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesCorrect device sizing for left atrial appendage (LAA) closure remains challenging due to complex LAA shapes. The aim of our study was to investigative the utility of personalized 3D-printed models (P3DPM) of the LAA to guide device size selection.MethodsFifteen patients (75.4 8.5years) scheduled for LAA closure using an Amulet device underwent cardiac computed tomography (CT). The LAA was segmented by semiautomatic algorithms using Vitrea (R) software. A 1.5-mm LAA thick shell was exported in stereolithography format and printed using TangoPlus flexible material. Different Amulet device sizes on the P3DPM were tested. New P3DPM-CT with the device was acquired in order to appreciate the proximal disc sealing the LAA ostium and the compression of the distal lobe within the LAA. We predicted the device size with P3DPM and compared this with the device sizes predicted by transesophageal echocardiography (TEE) and CT as well as the device size implanted in patients.ResultsThe device size predicted by 3D-TEE and CT corresponded to the implanted device size in 8/15 (53%) and 10/15 (67%), respectively. The predicted device size from the P3DPM was accurate in all patients, obtaining perfect contact with the LAA wall, without device instability or excessive compression. P3DPM-CT with the deployed device showed device deformation and positioning of the disk in relation to the pulmonary veins, allowing us to determine the best device size in all 15 cases.ConclusionP3DPM allowed us to simulate the LAA closure procedure and thus helped to identify the best Amulet size and position within the LAA.Key Points center dot A 3D-printed heart model allows to simulate the LAA closure procedure.center dot A 3D-printed heart model allowed to identify the optimal Amulet size and position. center dot 3D-printed heart models may contribute to reduce the Amulet implantation learning curve.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 25 条
[1]   A comparison of two-dimensional and real-time 3D transoesophageal echocardiography and angiography for assessing the left atrial appendage anatomy for sizing a left atrial appendage occlusion system: impact of volume loading [J].
Al-Kassou, Baravan ;
Tzikas, Apostolos ;
Stock, Friederike ;
Neikes, Fabian ;
Voelz, Alexander ;
Omran, Heyder .
EUROINTERVENTION, 2017, 12 (17) :2083-2091
[2]   Use of 3-Dimensional Models to Optimize Pre-Procedural Planning of Percutaneous Left Atrial Appendage Closure [J].
Bieliauskas, Gintautas ;
Otton, James ;
Chow, Danny H. F. ;
Sawaya, Fadi J. ;
Kofoed, Klaus F. ;
Sondergaard, Lars ;
De Backer, Ole .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (10) :1067-1070
[3]   Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation [J].
Blackshear, JL ;
Odell, JA .
ANNALS OF THORACIC SURGERY, 1996, 61 (02) :755-759
[4]   Analysis of in vivo left atrial appendage morphology in patients with atrial fibrillation: a direct comparison of transesophageal echocardiography, planar cardiac CT, and segmented three-dimensional cardiac CT [J].
Budge, Loren P. ;
Shaffer, Katherine M. ;
Moorman, J. Randall ;
Lake, Douglas E. ;
Ferguson, John D. ;
Mangrum, J. Michael .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (02) :87-93
[5]   ANMCO/AIAC/SICI-GISE/SIC/SICCH Consensus Document: percutaneous occlusion of the left atrial appendage in non-valvular atrial fibrillation patients: indications, patient selection, staff skills, organisation, and training [J].
Casu, Gavino ;
Gulizia, Michele Massimo ;
Molon, Giulio ;
Mazzone, Patrizio ;
Audo, Andrea ;
Casolo, Giancarlo ;
Di Lorenzo, Emilio ;
Portoghese, Michele ;
Pristipino, Christian ;
Ricci, Renato Pietro ;
Themistoclakis, Sakis ;
Padeletti, Luigi ;
Tondo, Claudio ;
Berti, Sergio ;
Oreglia, Jacopo Andrea ;
Gerosa, Gino ;
Zanobini, Marco ;
Ussia, Gian Paolo ;
Musumeci, Giuseppe ;
Romeo, Francesco ;
Di Bartolomeo, Roberto .
EUROPEAN HEART JOURNAL SUPPLEMENTS, 2017, 19 (0D) :D333-D353
[6]  
Chow DHF, 2017, OPEN HEART, V4, DOI 10.1136/openhrt-2017-000627
[7]  
Goitein O, 2017, EUROINTERVENTION, V13, P1076, DOI 10.4244/EIJ-D-16-00921
[8]   3D printing for sizing left atrial appendage closure device: head-to-head comparison with computed tomography and transoesophageal echocardiography [J].
Hell, Michaela M. ;
Achenbach, Stephan ;
Yoo, In Seong ;
Franke, Joerg ;
Blachutzik, Florian ;
Roether, Jens ;
Graf, Verena ;
Raaz-Schrauder, Dorette ;
Marwan, Mohamed ;
Schlundt, Christian .
EUROINTERVENTION, 2017, 13 (10) :1234-1241
[9]   Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial [J].
Holmes, David R. ;
Reddy, Vivek Y. ;
Turi, Zoltan G. ;
Doshi, Shephal K. ;
Sievert, Horst ;
Buchbinder, Maurice ;
Mullin, Christopher M. ;
Sick, Peter .
LANCET, 2009, 374 (9689) :534-542
[10]   Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin Therapy [J].
Holmes, David R., Jr. ;
Kar, Saibal ;
Price, Matthew J. ;
Whisenant, Brian ;
Sievert, Horst ;
Doshi, Shephal K. ;
Huber, Kenneth ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (01) :1-12