Comparative study on the performance of many-objective and single-objective optimisation algorithms in tuning load frequency controllers of multi-area power systems

被引:53
作者
Fini, Masoud Hajiakbari [1 ]
Yousefi, Gholam Reza [1 ]
Alhelou, Hassan Haes [1 ]
机构
[1] Isfahan Univ Technol, Dept Elect & Comp Engn, Esfahan 8415683111, Iran
关键词
power system control; frequency control; load regulation; pattern clustering; minimisation; evolutionary computation; many-objective optimisation algorithm; single-objective optimisation algorithm; load frequency controller tuning; multiarea power systems; single-objective evolutionary algorithms; many-objective minimisation problem; MO optimisation algorithm; clustering-based selection; performance indices; power system parameters variation; AUTOMATIC-GENERATION CONTROL; HARMONY SEARCH ALGORITHM; FUZZY-LOGIC CONTROLLER;
D O I
10.1049/iet-gtd.2015.1334
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Load frequency control is among the most important control tasks in power systems operation. Many researchers have focused on tuning the load frequency controllers using single-objective evolutionary algorithms. To avoid the drawbacks of single-objective optimisation algorithms, in this paper, tuning the load frequency controllers is modelled as a many-objective (MO) minimization problem. This MO optimisation problem is solved using an MO optimisation algorithm with clustering-based selection. Considering the maximum value of each objective among the non-dominated solutions found by the MO optimisation algorithm, the worst solution is determined. To select one of the obtained non-dominated solutions as the controllers' parameters, a strategy based on the maximum distance from the worst solution is proposed. In order to measure the effectiveness of the proposed MO technique against several recently proposed single-objective optimisation algorithms, for tuning load frequency controllers, comparative simulation studies are carried out on two different test systems. Simulation results show that, in terms of different performance indices, the controllers designed by the proposed MO method are far superior to the controllers designed with the single-objective optimisation algorithms. Also, the presented results confirm the robustness of the controllers designed by the proposed method in case of power system parameters variations.
引用
收藏
页码:2915 / 2923
页数:9
相关论文
共 26 条
[21]   A modified harmony search algorithm for solving load-frequency control of non-linear interconnected hydrothermal power systems [J].
Shivaie, Mojtaba ;
Kazemi, Mohammad G. ;
Ameli, Mohammad T. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2015, 10 :53-62
[22]   Fractional order PID controller design for LFC in electric power systems using imperialist competitive algorithm [J].
Taher, Seyed Abbas ;
Fini, Masoud Hajiakbari ;
Aliabadi, Saber Falahati .
AIN SHAMS ENGINEERING JOURNAL, 2014, 5 (01) :121-135
[23]   Linear active disturbance rejection-based load frequency control concerning high penetration of wind energy [J].
Tang, Yanmei ;
Bai, Yan ;
Huang, Congzhi ;
Du, Bin .
ENERGY CONVERSION AND MANAGEMENT, 2015, 95 :259-271
[24]   Quasi-oppositional harmony search algorithm and fuzzy logic controller for load frequency stabilisation of an isolated hybrid power system [J].
Tarkeshwar, Mahto ;
Mukherjee, Vivekananda .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (05) :427-444
[25]   Adaptive fuzzy logic load frequency control of multi-area power system [J].
Yousef, Hassan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 68 :384-395
[26]   A Knee Point-Driven Evolutionary Algorithm for Many-Objective Optimization [J].
Zhang, Xingyi ;
Tian, Ye ;
Jin, Yaochu .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2015, 19 (06) :761-776