The Effect of Fuel Injection Location on Supersonic Hydrogen Combustion in a Cavity-Based Model Scramjet Combustor

被引:20
作者
Jeong, Eunju [1 ]
O'Byrne, Sean [2 ]
Jeung, In-Seuck [1 ,3 ]
Houwing, A. F. P. [4 ]
机构
[1] Seoul Natl Univ, Dept Aerosp Engn, Seoul 08826, South Korea
[2] Univ New South Wales, Australian Def Force Acad, Sch Aerosp & Mech Engn, Canberra, ACT 2600, Australia
[3] Seoul Natl Univ, Inst Adv Aerosp Technol, Seoul 08826, South Korea
[4] Australian Natl Univ, Fac Sci, Dept Phys, GPO Box 4, Canberra, ACT 0200, Australia
关键词
supersonic combustion; scramjet combustor; cavity-based combustion; hydrogen combustion; FLAME STABILIZATION;
D O I
10.3390/en13010193
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Supersonic combustion experiments were performed using three different hydrogen fuel-injection configurations in a cavity-based model scramjet combustor with various global fuel-air equivalence ratios. The configurations tested were angled injection at 15 degrees to the flow direction upstream of the cavity, parallel injection from the front step, and upstream injection from the rear ramp. Planar laser-induced fluorescence of the hydroxyl radical and time-resolved pressure measurements were used to investigate the flow characteristics. Angled injection generated a weak bow shock in front of the injector and recirculation zone to maintain the combustion as the equivalence ratio increased. Parallel and upstream injections both showed similar flame structure over the cavity at low equivalence ratio. Upstream injection enhanced the fuel diffusion and enabled ignition with a shorter delay length than with parallel injection. The presence of a flame near the cavity was determined while varying the fuel injection location, the equivalence ratio, and total enthalpy of the air flow. The flame characteristics agreed with the correlation plot for the stable flame limit of non-premixed conditions. The pressure increase in the cavity for reacting flow compared to non-reacting flow was almost identical for all three configurations. More than 300 mm downstream of the duct entrance, averaged pressure ratios at low global equivalence ratio were similar for all three injection configurations.
引用
收藏
页数:16
相关论文
共 34 条
[1]   EXPERIMENTAL SUPERSONIC HYDROGEN COMBUSTION EMPLOYING STAGED INJECTION BEHIND A REARWARD-FACING STEP [J].
ABBITT, JD ;
SEGAL, C ;
MCDANIEL, JC ;
KRAUSS, RH ;
WHITEHURST, RB .
JOURNAL OF PROPULSION AND POWER, 1993, 9 (03) :472-478
[2]  
[Anonymous], P 43 AIAA ASME SAE A
[3]   FLAME STABILIZATION IN HIGH-VELOCITY HETEROGENEOUS FUEL-AIR MIXTURES [J].
BAXTER, MR ;
LEFEBVRE, AH .
JOURNAL OF PROPULSION AND POWER, 1992, 8 (06) :1138-1143
[4]  
Ben-Yakar A, 1998, TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P2173
[5]   Cavity flame-holders for ignition and flame stabilization in scramjets: An overview [J].
Ben-Yakar, A ;
Hanson, RK .
JOURNAL OF PROPULSION AND POWER, 2001, 17 (04) :869-877
[6]   SUPERSONIC-FLOW OVER A REARWARD FACING STEP WITH TRANSVERSE NON-REACTING HYDROGEN INJECTION [J].
BERMAN, HA ;
ANDERSON, JD ;
DRUMMOND, JP .
AIAA JOURNAL, 1983, 21 (12) :1707-1713
[7]   Complete three-dimensional multiparameter mapping of a supersonic ramp fuel injector flowfield [J].
Donohue, JM ;
McDaniel, JC .
AIAA JOURNAL, 1996, 34 (03) :455-462
[8]   Correlation and analysis of blowout limits of flames in high-speed airflows [J].
Driscoll, JF ;
Rasmussen, CC .
JOURNAL OF PROPULSION AND POWER, 2005, 21 (06) :1035-1044
[9]  
Ebrahimi H., 2007, P 45 AIAA AER SCI M
[10]   Wall pressure measurements for a sonic jet injected transversely into a supersonic crossflow [J].
Everett, DE ;
Woodmansee, MA ;
Dutton, JC ;
Morris, MJ .
JOURNAL OF PROPULSION AND POWER, 1998, 14 (06) :861-868