Direct determination of lead in plastic toys by solid sampling high resolution-continuum source graphite furnace atomic absorption spectrometry

被引:19
作者
Ozbek, Nil [1 ]
Ustabasi, Gul Sirin [1 ]
Akman, Suleyman [1 ]
机构
[1] Istanbul Tech Univ, Dept Chem, Fac Arts & Sci, TR-34469 Istanbul, Turkey
关键词
DUAL-CAVITY PLATFORM; ELECTRONIC EQUIPMENT; NICKEL CHLORIDE; FOOD SAMPLES; INTERFERENCES; ATOMIZATION; DIGESTION; CADMIUM; SULFUR; AAS;
D O I
10.1039/c5ja00185d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, lead concentrations in various plastic toys were determined directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry. The toys were cut into small pieces and introduced into the graphite furnace between 0.05 and 0.7 mg without any further treatment. Lead was determined at 217.005 nm using a Pd + Mg modifier. The samples were pyrolyzed at 1000 degrees C and atomized at 2200 degrees C with or without gas flow at the atomization stage depending on the concentration of the analyte. The lead concentration in a certified reference plastic material (ERM-EC680K) was determined in the uncertainty limits of the certified value. The limits of detection in gas-stop and gas-flow modes for 0.7 mg of sample were 0.037 and 0.93 mg kg(-1), respectively. The concentrations of lead in plastic toys of different colours were found to be in the range of 0.060-9.12 mg kg(-1).
引用
收藏
页码:1782 / 1786
页数:5
相关论文
共 26 条
[1]   Analysis of waste electrical and electronic equipment (WEEE) using laser induced breakdown spectroscopy (LIBS) and multivariate analysis [J].
Angel Aguirre, Miguel ;
Hidalgo, Montserrat ;
Canals, Antonio ;
Nobrega, Joaquim A. ;
Pereira-Filho, Edenir R. .
TALANTA, 2013, 117 :419-424
[2]  
Best D., 2008, TESTIMONY DANA BEST
[3]   Direct determination of phosphorus in different food samples by means of solid sampling electrothermal atomic absorption spectrometry using Pd plus Ca chemical modifier [J].
Coskun, N ;
Akman, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (03) :415-419
[4]   Severe lead poisoning in the plastics industry: A report of three cases [J].
Coyle, P ;
Kosnett, MJ ;
Hipkins, K .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2005, 47 (02) :172-175
[5]   Determination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometry [J].
Duarte, Alvaro T. ;
Dessuy, Morgana B. ;
Silva, Marcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard .
MICROCHEMICAL JOURNAL, 2010, 96 (01) :102-107
[6]   Quantification of heavy metals for the recycling of waste plastics from electrotechnical applications [J].
Ernst, T ;
Popp, R ;
van Eldik, R .
TALANTA, 2000, 53 (02) :347-357
[7]   Laser-induced breakdown spectroscopy and chemometrics for classification of toys relying on toxic elements [J].
Godoi, Quienly ;
Leme, Flavio O. ;
Trevizan, Lilian C. ;
Pereira Filho, Edenir R. ;
Rufini, Iolanda A. ;
Santos, Dario, Jr. ;
Krug, Francisco J. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (02) :138-143
[8]   Determination of sulphur in various vegetables by solid sampling high-resolution electrothermal molecular absorption spectrometry [J].
Gunduz, Sema ;
Akman, Suleyman .
FOOD CHEMISTRY, 2015, 172 :213-218
[9]  
Kumar A, 2007, CURR SCI INDIA, V93, P818
[10]   STATISTICAL TREATMENT OF ETA-AAS (ELECTROTHERMAL ATOMIZATION - ATOMIC-ABSORPTION SPECTROMETRY) SOLID SAMPLING DATA OF HETEROGENEOUS SAMPLES [J].
KURFURST, U .
PURE AND APPLIED CHEMISTRY, 1991, 63 (09) :1205-1211