Gaining Efficiency in the Laboratory - Automated Body Fluid Cell Counts: Evaluation of the Body Fluid Application on the Sysmex XE-5000 Hematology Analyzer

被引:8
|
作者
Williams, James E. [1 ]
Walters, Jeri [1 ]
Kabb, Kimberley [1 ]
机构
[1] ACL Labs, Milwaukee, WI USA
来源
LABMEDICINE | 2011年 / 42卷 / 07期
关键词
hematology; body fluids; automated cell counts;
D O I
10.1309/V1HMLAYJRY01RT
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: To investigate the performance of the body fluid application on the Sysmex XE-5000, Methods: The XE-5000 accuracy, precision, and analytic measurement range, as well as correlation with standard methods were evaluated using serous, synovial, and cerebrospinal fluids (CSFs). Results: The body fluid application on the XE-5000 showed good precision and correlation with previous methods for nucleated cell counts and RBC counts. Conclusion: Evaluation of the body fluid application on the Sysmex XE-5000 showed significant improvement in the ability of automated hematology analyzers regarding body fluid analysis.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 7 条
  • [1] Performance evaluation of the body fluid mode on the platform Sysmex XE-5000 series automated hematology analyzer
    Paris, A.
    Nhan, T.
    Cornet, E.
    Perol, J. -P.
    Malet, M.
    Troussard, X.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (05) : 539 - 547
  • [2] Body Fluid Cell Counts by Automated Methods
    Sandhaus, Linda M.
    CLINICS IN LABORATORY MEDICINE, 2015, 35 (01) : 93 - +
  • [3] Preliminary evaluation of UF-5000 Body Fluid Mode for automated cerebrospinal fluid cell counting
    Seghezzi, Michela
    Manenti, Barbara
    Previtali, Giulia
    Alessio, Maria Grazia
    Dominoni, Paola
    Buoro, Sabrina
    CLINICA CHIMICA ACTA, 2017, 473 : 133 - 138
  • [4] Performance evaluation of automated cell counts compared with reference methods for body fluid analysis
    Seghezzi, Michela
    Previtali, Giulia
    Moioli, Valentina
    Alessio, Maria Grazia
    Guerra, Giovanni
    Buoro, Sabrina
    DIAGNOSIS, 2022, 9 (03) : 369 - 378
  • [5] Performance evaluation of UF-4000 body fluid mode for automated body fluid cell counting
    Siatkowski, Marie
    Dahyot, Sandrine
    Pestel-Caron, Martine
    Boyer, Sophie
    CLINICA CHIMICA ACTA, 2022, 531 : 152 - 156
  • [6] Two-site evaluation of a new workflow for the detection of malignant cells on the Sysmex XN-1000 body fluid analyzer
    Favresse, Julien
    Boland, Lidvine
    Schellen, Marie
    Fervaille, Caroline
    Wuestenberghs, Fabien
    Camboni, Alessandra
    Chatelain, Bernard
    Mullier, Francois
    Defour, Jean-Philippe
    Jacqmin, Hugues
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2020, 42 (05) : 544 - 551
  • [7] Evaluation of automated synovial fluid total cell count and percent polymorphonuclear leukocytes on a Sysmex XN-1000 analyzer for identifying patients at risk of septic arthritis
    Saadalla, Abdulrahman
    Aguirre, Jose Jara
    Wockenfus, Amy M.
    Kelley, Brandon R.
    Swanson, Rebecca L.
    Howard, Matthew T.
    Karon, Brad S.
    CLINICA CHIMICA ACTA, 2020, 510 : 416 - 420