Present Estimates of the Differences Between Thermodynamic Temperatures and the ITS-90

被引:102
作者
Fischer, J. [1 ]
de Podesta, M. [2 ]
Hill, K. D. [3 ]
Moldover, M. [4 ]
Pitre, L. [5 ]
Rusby, R. [2 ]
Steur, P. [6 ]
Tamura, O. [7 ]
White, R. [8 ]
Wolber, L. [1 ]
机构
[1] PTB, D-10587 Berlin, Germany
[2] NPL, Teddington, Middx, England
[3] NRC, Ottawa, ON, Canada
[4] NIST, Gaithersburg, MD 20899 USA
[5] LNE INM CNAM, Paris, France
[6] INRiM, Turin, Italy
[7] AIST, NMIJ, Tsukuba, Ibaraki, Japan
[8] MSL, Lower Hutt, New Zealand
关键词
Differences T-T-90; International Temperature Scale ITS-90; Primary thermometry; Thermodynamic temperature; GAS-THERMOMETRY SCALE; ACOUSTIC THERMOMETRY; RADIOMETRIC DETERMINATION; FREEZING POINTS; TRIPLE POINT; RANGE; CONSTANT; REALIZATION; HE-3; GALLIUM;
D O I
10.1007/s10765-011-0922-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
At the request of the Consultative Committee for Thermometry (CCT), Working Group 4 (WG4) has critically reviewed all available measurements of the differences between thermodynamic and ITS-90 temperatures, (T - T (90)), and documented the conversion of older data to the ITS-90. Particular attention has been given to the uncertainties. Based on this review, we provide consensus estimates of T - T (90) for selected measurements from 0.65 K to 1358 K. We provide two analytic functions for T - T (90), one for use from 8 K to the triple point of water (T (TPW)) and one for use above T (TPW). The small discontinuity of the derivative dT (90)/d T at T (TPW) is discussed. We also identify temperature ranges where researchers are encouraged to undertake high-accuracy measurements of T - T (90).
引用
收藏
页码:12 / 25
页数:14
相关论文
共 49 条
[41]   NBS NIST GAS THERMOMETRY FROM 0-DEGREES-C TO 660-DEGREES-C [J].
SCHOOLEY, JF .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (03) :255-290
[42]   CORRELATION BETWEEN THE RESISTANCE RATIOS OF PLATINUM RESISTANCE THERMOMETERS AT THE MELTING-POINT OF GALLIUM AND THE TRIPLE POINT OF MERCURY [J].
SINGH, YP ;
MAAS, H ;
EDLER, F ;
ZAIDI, ZH .
METROLOGIA, 1994, 31 (01) :49-50
[43]   CONSTANT-VOLUME GAS THERMOMETRY BETWEEN 4-K AND 100-K [J].
STEUR, PPM ;
DURIEUX, M .
METROLOGIA, 1986, 23 (01) :1-18
[44]   The double-heatpipe black body: A high-accuracy standard source of spectral irradiance for measurements of T-T-90 [J].
Stock, M ;
Fischer, J ;
Friedrich, R ;
Jung, HJ ;
Wende, B .
METROLOGIA, 1996, 32 (06) :441-444
[45]  
Strouse GF, 2003, AIP CONF PROC, V684, P31, DOI 10.1063/1.1627096
[46]   NMIJ constant-volume gas thermometer for realization of the ITS-90 and thermodynamic temperature measurement [J].
Tamura, O. ;
Takasu, S. ;
Nakano, T. ;
Sakurai, H. .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (01) :31-41
[47]  
Taubert DR, 2003, AIP CONF PROC, V684, P7, DOI 10.1063/1.1627092
[48]   Measurement time and statistics for a noise thermometer with a synthetic-noise reference [J].
White, D. R. ;
Benz, S. P. ;
Labenski, J. R. ;
Nam, S. W. ;
Qu, J. F. ;
Rogalla, H. ;
Tew, W. L. .
METROLOGIA, 2008, 45 (04) :395-405
[49]  
YOON HW, 2004, P TEMPMEKO 2004 CAVT, P59