Behavior of Fully Encased Steel-Concrete Composite Columns Subjected to Monotonic and Cyclic Loading

被引:43
作者
Campian, Cristina [1 ]
Nagy, Zsolt [1 ]
Pop, Maria [1 ]
机构
[1] Tech Univ Cluj Napoca, Fac Civil Engn, 15 C Daicoviciu Str, Cluj Napoca 400020, Romania
来源
INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015) | 2015年 / 117卷
关键词
steel-concrete composite column; bearing capacity; monotonic and cyclic loading; CFST COLUMNS;
D O I
10.1016/j.proeng.2015.08.193
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper describes experimental aspects for composite steel-concrete columns, with steel encased profile. In composite columns with HSC case, even if elastic displacement v(y) decreases, the value of the lateral force H-y corresponding to the v(y) displacement and the maximum lateral loading H-max indicates a significant increase. Failure modes were different, characterized by sudden and violent concessions due to cracking developments through aggregate in columns with HSC, while columns with NSC shows a "slow" failure mode characterized by gradual decline of bearing capacity with the growth of the displacements. It is well known that the high strength concrete is more susceptible to fragile failure than the normal concrete, so it is, in a way, the presumed result. On the other hand, from the graphics and parameters analysis we can conclude that the columns with HSC have a higher energy absorption capacity, which can recommend this solution to the construction in seismic areas, even the failure mode was brittle. In structural terms, composite columns with concrete class C70/85 provide obvious better performances to structures, having significant increases to almost all analyzed parameters. The solution of fully encased composite column is a competitive solution for seismic and non-seismic zones, due to the excellent seismic performances (resulted from the presented experimental tests) and also because of improved fire protection. The results obtained on the columns made with high strength concrete showed improved performances, especially resistance. Due to the brittle fracture of the high strength concrete more experimental and numerical research must still be made. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:439 / 451
页数:13
相关论文
共 29 条
[1]   Behaviour of concrete-encased CFST columns under combined compression and bending [J].
An, Yu-Feng ;
Han, Lin-Hai .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 :314-330
[2]  
[Anonymous], 2014, APPL MECH MAT, V633-634, P1069
[3]  
[Anonymous], 2015, APPL MECH MAT, V725-726, P903
[4]  
[Anonymous], 2015, APPL MECH MAT, V725-726, P410
[5]  
[Anonymous], J APPL ENG SCI
[6]  
Aribert JM, 2003, STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, P115
[7]  
Campian C., 2010, P STEEL STRUCT CULT, P485
[8]  
Campian C., 2001, THESIS
[9]   Development and competitiveness improvement of the construction sector in Montenegro [J].
Cetkovic, Jasmina ;
Knezevic, Milos ;
Zarkovic, Milos ;
Murgul, Vera ;
Vatin, Nikolay .
PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING III, PT 1, 2014, 638-640 :2465-+
[10]   Experimental behaviour and strength of concrete-encased composite beam-columns with T-shaped steel section under cyclic loading [J].
Chen, CC ;
Li, JM ;
Weng, CC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (07) :863-881