Ultraviolet light disinfection of hospital water for preventing nosocomial Legionella infection:: A 13-year follow-up

被引:25
作者
Hall, KK [1 ]
Giannetta, ET [1 ]
Getchell-White, SI [1 ]
Durbin, LJ [1 ]
Farr, BM [1 ]
机构
[1] Univ Virginia, Hlth Syst, Charlottesville, VA 22908 USA
关键词
D O I
10.1086/502257
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BACKGROUND AND OBJECTIVE: CDC has estimated that 23% of Legionella infections are nosocomial. When a new hospital was being constructed and a substantial increase in transplantation was anticipated, an ultraviolet light apparatus was installed in the water main of the new building because 27% of water samples from taps in the old hospital contained Legionella. This study reports the rate of nosocomial Legionella infection and water contamination since opening the new hospital. METHODS: Charts of all patients with positive Legionella cultures, direct immunofluorescent antibody (DFA), or urine antigen between April 1989 and November 2001 were reviewed. Frequencies of DFAs and urine antigens were obtained from the laboratory. RESULTS: None of the 936 cultures of hospital water have been positive since moving into the new building. Fifty-three (0.02%) of 219,521 patients had a positive Legionella test; 41 had pneumonia (40 community acquired). One definite L pneumophila pneumonia confirmed by culture and DFA in August 1994 was nosocomial (0.0005%) by dates. This patient was transferred after prolonged hospitalization in another country, was transplanted 11 days after admission, and developed symptoms 5 days after Ever transplant. However, tap water from the patients room did not grow Legionella. Seventeen (2.5%) of 670 urine antigens were positive for Legionella (none nosocomial). Thirty-three (1.2%) of 2,671 DFAs were positive, including 7 patients (21%) without evidence of pneumonia and 6 (18%) who had an alternative diagnosis. CONCLUSION: Ultraviolet light usage was associated with negative water cultures and lack of clearly documented nosocomial Legionella infection for 13 years at this hospital.
引用
收藏
页码:580 / 583
页数:4
相关论文
共 30 条
[1]  
[Anonymous], 2000, MMWR Recomm Rep, V49, P1
[2]  
[Anonymous], 1997, MMWR Recomm Rep, V46, P1
[3]   SUSCEPTIBILITY OF LEGIONELLA-PNEUMOPHILA TO ULTRAVIOLET-RADIATION [J].
ANTOPOL, SC ;
ELLNER, PD .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1979, 38 (02) :347-348
[4]   RISK-FACTORS FOR NOSOCOMIAL LEGIONELLA-PNEUMOPHILA PNEUMONIA [J].
CARRATALA, J ;
GUDIOL, F ;
PALLARES, R ;
DORCA, J ;
VERDAGUER, R ;
ARIZA, J ;
MANRESA, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (03) :625-629
[5]   Nosocomial legionnaires' disease caused by Legionella pneumophila serogroup 5: Laboratory and epidemiologic implications [J].
Chang, FY ;
Jacobs, SL ;
Colodny, SM ;
Stout, JE ;
Yu, VL .
JOURNAL OF INFECTIOUS DISEASES, 1996, 174 (05) :1116-1119
[6]   Emerging waterborne infections in health-care settings [J].
Emmerson, AM .
EMERGING INFECTIOUS DISEASES, 2001, 7 (02) :272-276
[7]  
FARR BM, 1988, LANCET, V2, P669
[8]   A survey of methods used to detect nosocomial legionellosis among participants in the National Nosocomial, Infections Surveillance System [J].
Fiore, AE ;
Butler, JC ;
Emori, TG ;
Gaynes, RP .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (06) :412-416
[9]   LEGIONNAIRES DISEASE - DESCRIPTION OF AN EPIDEMIC OF PNEUMONIA [J].
FRASER, DW ;
TSAI, TR ;
ORENSTEIN, W ;
PARKIN, WE ;
BEECHAM, HJ ;
SHARRAR, RG ;
HARRIS, J ;
MALLISON, GF ;
MARTIN, SM ;
MCDADE, JE ;
SHEPARD, CC ;
BRACHMAN, PS .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 297 (22) :1189-1197
[10]   SCREENING FOR NOSOCOMIAL LEGIONELLOSIS BY CULTURE OF THE WATER-SUPPLY AND TARGETING OF HIGH-RISK PATIENTS FOR SPECIALIZED LABORATORY TESTING [J].
GOETZ, A ;
YU, VL .
AMERICAN JOURNAL OF INFECTION CONTROL, 1991, 19 (02) :63-66