摘要
The use of a newly synthesized chelating resin with an o-aminophenol - type functional groups and Amberlite XAD-1180 - type supporting material for separation/ preconcentration of trace metal ions from various water samples was described. Amberlite XAD-1180-o-aminophenol chelating resin (XAD-o-AP) was synthesized using Amberlite XAD-1180 resin as solid support and o-aminophenol as the chelating ligand. The determination of Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) ions was made by flame atomic absorption spectrometry (FAAS). Studying with model solutions for the optimization of the method was based on the measurement of recovery values (between 92-106%) of the analyte elements. Some analytical parameters such as pH (6.0), volume of the sample (similar to 250 mL), effect of matrix ions, flow rates of the sample (2.5 mL min(-1)) and elution solutions (2.5 mL min(-1)), concentration, type and volume of the eluent (4 mol L-1 HNO3, 20 mL) were investigated. The detection limit (3s/b, n = 20) and the relative standard deviation (n = 7) of the method were found to be in the range 0.9-4.3 mu g L-1 and 4.4-5.5%, respectively. The proposed method was successfully applied to the real samples such as wastewater, boiler feeding water and a certified reference material (Estuarine water, LGC 6016).
引用
收藏
页码:3199 / 3215
页数:17
相关论文
共 38 条
[1]   Studies on uptake behaviour of copper(II) and lead(II) by arnine chelating resins with different textural properties [J].
Atia, AA ;
Donia, AM ;
Abou-El-Enein, SA ;
Yousif, AM .
SEPARATION AND PURIFICATION TECHNOLOGY, 2003, 33 (03) :295-301
[2]   Determination of iron and nickel by flame atomic absorption spectrophotometry after preconcentration on Saccharomyces cerevisiae immobilized sepiolite [J].
Bag, H ;
Lale, M ;
Turker, AR .
TALANTA, 1998, 47 (03) :689-696
[3]   Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[4]   Selective extraction of thallium(III) in the presence of gallium(III), indium(III), bismuth(III) and antimony(III) by salting-out of an aqueous mixture of 2-propanol [J].
Chung, NH ;
Nishimoto, J ;
Kato, O ;
Tabata, M .
ANALYTICA CHIMICA ACTA, 2003, 477 (02) :243-249
[5]   DETERMINATION OF SUB-MU-G/G AMOUNTS OF VANADIUM IN IRON BY N-BENZOYL-N-PHENYLHYDROXYLAMINE-CHLOROFORM SOLVENT-EXTRACTION ICP-AES [J].
DANZAKI, Y .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :103-106
[6]   Electrochemical deposition of 5,10,15,20-tetrakis-(4-sulphonatophenyl) porphyrin and its Co(II) derivative at a gold microelectrode array [J].
De Wael, K ;
Adriaens, A ;
Temmerman, E .
ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) :60-65
[7]   Speciation analysis of chromium by separation on a 5-palmitoyl oxine-functionalized XAD-2 resin and spectrophotometric determination with diphenylcarbazide [J].
Filik, H ;
Dogutan, M ;
Apak, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (06) :928-933
[8]   1,8-dihydroxyanthraquinone anchored on silica gel: synthesis and application as solid phase extractant for lead(II), zinc(II) and cadmium(II) prior to their determination by flame atomic absorption spectrometry [J].
Goswami, A ;
Singh, AK .
TALANTA, 2002, 58 (04) :669-678
[9]   Silica gel functionalized with resacetophenone: synthesis of a new chelating matrix and its application as metal ion collector for their flame atomic absorption spectrometric determination [J].
Goswami, A ;
Singh, AK .
ANALYTICA CHIMICA ACTA, 2002, 454 (02) :229-240
[10]   Preconcentration and determination of trace elements with 2-aminoacetylthiophenol functionalized Amberlite XAD-2 by inductively coupled plasma-atomic emission spectrometry [J].
Guo, Y ;
Din, BJ ;
Liu, YG ;
Chang, XJ ;
Meng, SM ;
Liu, JH .
TALANTA, 2004, 62 (01) :209-215