A full-scale field study for performance evaluation of axially loaded large-diameter cylinder piles with pipe piles and PSC piles

被引:29
作者
Abu-Farsakh, Murad Y. [1 ]
Haque, Md. Nafiul [2 ]
Tsai, Ching [3 ]
机构
[1] Louisiana State Univ, Louisiana Transportat Res Ctr, Baton Rouge, LA 70808 USA
[2] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70808 USA
[3] Louisiana Dept Transportat & Dev, Engineer DCL 6, Baton Rouge, LA 70804 USA
关键词
CAPWAP; Dynamic load test; Large-diameter cylinder pile; Pipe pile; Pile setup; PSC pile; Open-ended pile; Statnamic load test; Static load test; Soil plug; OPEN-ENDED PILES; CAPACITY; DRIVEN; FRICTION; TIME; SETUP; CPT;
D O I
10.1007/s11440-016-0498-9
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper presents the results from a pile load testing program for a bridge construction project in Louisiana. The testing includes two 54-in. open-ended spun cast concrete cylinder piles, one 30-in. open-ended steel pile and two (30- and 16-in.) square prestressed concrete (PSC) piles driven at two locations with very similar soil conditions. Both cone penetration tests (CPTs) and soil borings/laboratory testing were used to characterize the subsurface soil conditions. All the test piles were instrumented with vibrating wire strain gauges to measure the load distribution along the length of the test piles and measure the skin friction and end-bearing capacity, separately. Dynamic load tests were performed on all test piles at different times after pile installations to quantify the amount of setup with time. Static load tests were also performed on the PSC and open-ended steel piles. Due to expected large pile capacities, the statnamic test method was used on the two open-ended cylinder piles. The pile capacities of these piles were evaluated using various CPT methods (such as Schmertmann, De Ruiter and Beringen, LCPC, Lehane et al. methods). The result showed that all the methods can estimate the skin friction with good accuracy, but not the end-bearing capacity. The normalized cumulative blow counts during pile installation showed that the blow count was always higher for the PSC piles compared to the large-diameter open-ended cylinder pile, regardless of pile size and hammer size. Setup was observed for all the piles, which was mainly attributed to increase in skin frictions. The setup parameters "A" were back-calculated for all the test piles and the values were between 0.31 and 0.41.
引用
收藏
页码:753 / 772
页数:20
相关论文
共 56 条
[1]  
Abu-Farsakh M, 2004, FHWALA03386 LOUIS TR
[2]   Evaluating pile installation and subsequent thixotropic and consolidation effects on setup by numerical simulation for full-scale pile load tests [J].
Abu-Farsakh, Murad ;
Rosti, Firouz ;
Souri, Ahmad .
CANADIAN GEOTECHNICAL JOURNAL, 2015, 52 (11) :1734-1746
[3]  
Abu-Farsakh MY, 2007, GEOTECH TEST J, V30, P387
[4]   Assessment of direct cone penetration test methods for predicting the ultimate capacity of friction driven piles [J].
Abu-Farsakh, MY ;
Titi, HH .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2004, 130 (09) :935-944
[5]  
[Anonymous], 1995, REPORT 395 2
[6]  
Axelsson G, 2000, THESIS
[7]   MEASURED AND PREDICTED AXIAL RESPONSE OF 98 PILES [J].
BRIAUD, JL ;
TUCKER, LM .
JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1988, 114 (09) :984-1001
[8]   Side shear setup. I: Test piles driven in Florida [J].
Bullock, PJ ;
Schmertmann, JH ;
McVay, MC ;
Townsend, FC .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2005, 131 (03) :292-300
[9]  
Bustamante M., 1982, P 2 EUROPEAN S PENET, P493
[10]   Field Investigation of Pile Setup in Mixed Soil [J].
Chen, Qiming ;
Haque, Md. Nafiul ;
Abu-Farsakh, Murad ;
Fernandez, Benjamin A. .
GEOTECHNICAL TESTING JOURNAL, 2014, 37 (02)