A full-scale field study for performance evaluation of axially loaded large-diameter cylinder piles with pipe piles and PSC piles

被引:27
|
作者
Abu-Farsakh, Murad Y. [1 ]
Haque, Md. Nafiul [2 ]
Tsai, Ching [3 ]
机构
[1] Louisiana State Univ, Louisiana Transportat Res Ctr, Baton Rouge, LA 70808 USA
[2] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70808 USA
[3] Louisiana Dept Transportat & Dev, Engineer DCL 6, Baton Rouge, LA 70804 USA
关键词
CAPWAP; Dynamic load test; Large-diameter cylinder pile; Pipe pile; Pile setup; PSC pile; Open-ended pile; Statnamic load test; Static load test; Soil plug; OPEN-ENDED PILES; CAPACITY; DRIVEN; FRICTION; TIME; SETUP; CPT;
D O I
10.1007/s11440-016-0498-9
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper presents the results from a pile load testing program for a bridge construction project in Louisiana. The testing includes two 54-in. open-ended spun cast concrete cylinder piles, one 30-in. open-ended steel pile and two (30- and 16-in.) square prestressed concrete (PSC) piles driven at two locations with very similar soil conditions. Both cone penetration tests (CPTs) and soil borings/laboratory testing were used to characterize the subsurface soil conditions. All the test piles were instrumented with vibrating wire strain gauges to measure the load distribution along the length of the test piles and measure the skin friction and end-bearing capacity, separately. Dynamic load tests were performed on all test piles at different times after pile installations to quantify the amount of setup with time. Static load tests were also performed on the PSC and open-ended steel piles. Due to expected large pile capacities, the statnamic test method was used on the two open-ended cylinder piles. The pile capacities of these piles were evaluated using various CPT methods (such as Schmertmann, De Ruiter and Beringen, LCPC, Lehane et al. methods). The result showed that all the methods can estimate the skin friction with good accuracy, but not the end-bearing capacity. The normalized cumulative blow counts during pile installation showed that the blow count was always higher for the PSC piles compared to the large-diameter open-ended cylinder pile, regardless of pile size and hammer size. Setup was observed for all the piles, which was mainly attributed to increase in skin frictions. The setup parameters "A" were back-calculated for all the test piles and the values were between 0.31 and 0.41.
引用
收藏
页码:753 / 772
页数:20
相关论文
共 50 条
  • [1] A full-scale field study for performance evaluation of axially loaded large-diameter cylinder piles with pipe piles and PSC piles
    Murad Y. Abu-Farsakh
    Md. Nafiul Haque
    Ching Tsai
    Acta Geotechnica, 2017, 12 : 753 - 772
  • [2] PERFORMANCE OF AXIALLY LOADED PIPE PILES IN SAND
    KRAFT, LM
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1991, 117 (02): : 272 - 296
  • [3] Full-Scale Laboratory Test of Cutting Large-Diameter Piles Directly by Shield Cutterhead
    Wang, Yuqing
    Wang, Xinyu
    Xiong, Yangyang
    Yang, Zhuangzhi
    Zhang, Jie
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022
  • [4] PERFORMANCE OF AXIALLY LOADED PIPE PILES IN SAND - DISCUSSION
    CLEMENTE, JLM
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1992, 118 (05): : 832 - 835
  • [5] Horizontal dynamic response of offshore large-diameter pipe piles
    Zheng, Changjie
    Lin, Hao
    Cao, Guangwei
    Luan, Lubao
    OCEAN ENGINEERING, 2023, 272
  • [6] PERFORMANCE OF AXIALLY LOADED STEEL PIPE PILES DRIVEN IN SOFT ROCK
    MATSUMOTO, T
    MICHI, Y
    HIRANO, T
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1995, 121 (04): : 305 - 315
  • [7] Case study on pile running during the driving process of large-diameter pipe piles
    Sun, Liqiang
    Wang, Yandi
    Guo, Wei
    Yan, Shuwang
    Chu, Jian
    Liu, Xiaoqiang
    MARINE GEORESOURCES & GEOTECHNOLOGY, 2018, 36 (06) : 709 - 721
  • [8] Vertical bearing capacity characteristics of large-diameter DPC pipe piles based on field tests
    Hu, Hesong
    Tang, Mengxiong
    Liu, Chunlin
    Chen, Hang
    Zhang, Shuo
    Ling, Zao
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 (02): : 92 - 99
  • [9] Large-scale testing facility for cyclic axially loaded piles
    Baessler, Matthias
    Ruecker, Werner
    Cuellar, Pablo
    Georgi, Steven
    Karabeliov, Krassimire
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2013, 6 (03): : 200 - 206
  • [10] Impedance of Inner Saturated Soil to Horizontally Vibrating Large-Diameter Pipe Piles
    Xie, Jiang
    SHOCK AND VIBRATION, 2021, 2021