Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

被引:4
|
作者
Roteta, Miguel
Peyres, Virginia
Rodriguez Barquero, Leonor
Garcia-Torano, Eduardo
Arenillas, Pablo
Balpardo, Christian
Rodrigues, Dario
Llovera, Roberto
机构
关键词
Ga-68; Ge-68; Radionuclide standardization; IMPLEMENTATION; GE-68/GA-68; EFFICIENCY; EMITTERS;
D O I
10.1016/j.apradiso.2012.02.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The radionuclide Ga-68 is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of Zn-68 partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4 pi beta-gamma coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar Nal detectors was used instead. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2006 / 2011
页数:6
相关论文
共 50 条
  • [41] Activity standardization of 41Ca by means of liquid scintillation counting
    Kossert, K.
    Joerg, G.
    von Gostomski, Ch. Lierse
    RADIOCHIMICA ACTA, 2009, 97 (01) : 1 - 8
  • [42] Primary standardization of 224Ra activity by liquid scintillation counting
    Napoli, Elisa
    Cessna, Jeffrey T.
    Fitzgerald, Ryan
    Pibida, Leticia
    Colle, Ronald
    Laureano-Perez, Lizbeth
    Zimmerman, Brian E.
    Bergeron, Denis E.
    APPLIED RADIATION AND ISOTOPES, 2020, 155
  • [43] Standardization of Tc-99 by three liquid scintillation counting methods
    van Wyngaardt, W. M.
    van Staden, M. J.
    Lubbe, J.
    Simpson, B. R. S.
    APPLIED RADIATION AND ISOTOPES, 2014, 87 : 254 - 259
  • [44] A NOVEL-APPROACH TO EXTERNAL STANDARDIZATION IN LIQUID SCINTILLATION-COUNTING
    DEFILIPPIS, SJ
    VANCAUTER, SC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1985, 50 (NOV): : 22 - 23
  • [45] STANDARDIZATION OF PURE BETA-EMITTERS BY LIQUID-SCINTILLATION COUNTING
    POCHWALSKI, K
    BRODA, R
    RADOSZEWSKI, T
    APPLIED RADIATION AND ISOTOPES, 1988, 39 (02) : 165 - 172
  • [46] Primary standardization of 212Pb activity by liquid scintillation counting
    Bergeron, Denis E.
    Cessna, Jeffrey T.
    Fitzgerald, Ryan P.
    Laureano-Perez, Lizbeth
    Pibida, Leticia
    Zimmerman, Brian E.
    APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [47] LIQUID-SCINTILLATION COUNTING TECHNIQUES FOR THE STANDARDIZATION OF RADIONUCLIDES USED IN THERAPY
    COURSEY, BM
    CALHOUN, JM
    CESSNA, J
    GOLAS, DB
    SCHIMA, FJ
    UNTENWEGER, MP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 26 - 30
  • [48] PROPORTIONAL AND SCINTILLATION COUNTERS USED IN COINCIDENCE COUNTING
    BEKUZAROV, DN
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 201 - 208
  • [49] Application of the triple-to-double coincidence ratio (TDCR) method for the absolute standardization of radionuclides by liquid scintillation counting.
    Zimmerman, BE
    Colle, R
    Cessna, JT
    Broda, R
    Cassette, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : B154 - B154
  • [50] COINCIDENCE EXPERIMENTS FOR NOISE REDUCTION IN SCINTILLATION COUNTING
    KALLMANN, H
    ACCARDO, CA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (01): : 48 - 51